• Title/Summary/Keyword: cleaner

Search Result 673, Processing Time 0.026 seconds

The effects of a newsletter on bedding control on house dust mite allergen concentrations in childcare centers in Korea

  • Kim, Jeonghoon;Jeong, Kyoung Yong;Kwon, Ho-Jang;Yang, Heasuk;Yum, Hye Yung;Lee, Seon Ah;Kim, Chae-Bong;Kim, Hyunjung;Lim, Wan Ryung;Hong, Soyoung;Kim, Kyoosang
    • Environmental Analysis Health and Toxicology
    • /
    • v.30
    • /
    • pp.8.1-8.8
    • /
    • 2015
  • Objectives Bedding in childcare centers (CCCs) can hold house dust mite (HDM) allergens. This study examined whether HDM allergen levels can be reduced through the distribution of an educational newsletter on bedding control to parents of CCC children in Korea. Methods All 38 CCCs were measured for Der 1 (sum of Der f 1 and Der p 1) concentrations on classroom floors and bedding before the intervention. Educational newsletters on children's bedding control were sent to 21 CCCs by mail, and teachers were asked to distribute the newsletters to the parents of the children (intervention group). The remaining 17 CCCs were not sent newsletters (control group). The measurement of Der 1 concentrations in 38 CCCs was repeated after the intervention. Dust samples were collected with a vacuum cleaner and analyzed using enzyme-linked immunosorbent assay methods. Results The Der 1 concentrations on the bedding were significantly higher than those on the floors in 38 CCCs at baseline (p < 0.05). Although changes of the Der 1 concentrations for the control group (n=17) were not significant, Der 1 concentrations for the intervention group (n=21) decreased significantly from 2077.9 ng/g dust to 963.5 ng/g dust on the floors and from 3683.9 ng/g dust to 610.4 ng/g dust on bedding (p < 0.05). Conclusions The distribution of educational newsletters on bedding control to parents may be an effective means of controlling HDMs in CCCs.

Investigation into the Scaling the Actual Condition of Patients at the Oral Prophylaxis Lab in D College in Gangwon Province and Their use of Oral Hygiene Supplies (강원지역 D대학의 치면세마 실습 내원환자에 대한 스켈링 실태 및 구강위생용품 사용 실태 조사)

  • Hong, Min-Hee;Jeong, Mi-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.166-173
    • /
    • 2009
  • The purpose of this study was to examine the satisfaction level of patients with oral health care provided by a dental hospital, especially scaling, and their oral health behavior. The subjects in this study were 263 college students who were in their 20s and selected from among patients who visited D university dental hospital in Gangwon Province during the oral prophylaxis practice of dental hygiene sophomores and juniors. The findings of the study were as follows: 1. Whether the selected students had ever had their teeth scaled was checked, and those who had outnumbered the others who hadn't. The rates of the former and latter respectively stood at 61.2 percent and 38.8 percent. Regarding places where they got their teeth scaled, the majority of the students that represented 75.2 percent did that at dental clinics. By gender, 34.4 percent of the male students did that at schools, which were larger than 11.8 percent of the female students who did. 88.2 percent of the female students did that at dental clinics, which were larger than 65.5 percent of the male students who did. Gender made significant differences to that(x2=10.79, p<.01). 2. As for satisfaction level with scaling by gender, the male students (38.7%) who had no specific idea outnumbered the female students (26.5%) who did. The female students(57.4%) who felt no pain during scaling outnumbered the male students(55.9%) who did. Gender made a significant difference to their responses. (x2=6.38, p<.05). 3. Concerning the use of oral hygiene supplies, most of the students who represented 72.2 percent had never flossed their teeth, and as many as 86.3 percent had never used a tongue cleaner. But the gaps between them and the others were not statistically significant.

Automation of Longline -Automation of the Alaska Pollack Longline- (주낙어구의 자동화 -명태주낙어업의 자동화-)

  • KO Kwan-Soh;YOON Gab-Dong;LEE Chun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.2
    • /
    • pp.106-113
    • /
    • 1987
  • The Alaska pollack longline operations, which consist of baiting, shooting, hauling and arrangement of hooks, are dependant on manual labour up to the present. The automation against this traditional way is necessary to eliminate the manual operations and to reduce crew. We have developed a prototype longline system suitable for Alaska pollack longline gear, which is composed of an automatic baiting machine, an automatic line hauler, a hook cleaner and storage rails. The automatic bailing machine driven by hydraulic power is precise baiting method controlled sequentially, and the automatic line hauler is to haul up the mainline by means of hydraulic power and at the same time to split every hook and to carry it onto storage rail automatically. A series functioning tests on shooting and hauling apparatus were carried out in the laboratory and at sea. The results obtained are as follows ; 1. As for the baiting machine, the exciting time of solenoid which operates a directional valve, bait feeding and cutting time, is shortened according to the increase of pressure, and also, after cutting the bait, the over-rotated angle of the blade increased in accordance with the increase of pressure. 2. The baiting efficiency is about $90\%$ when using sand lance (Hypoptychus dybowskii), and the most proper pressure of the hydraulic circuit in feeding and cutting the bait is between $13\;kgf/cm^2\;and\;20\;kgf/cm^2$. 3. The hook splitting rate of the automatic line hauler is about $95.5\%$ regardless of hauling speed and materials of snood. 4. The case of unseparating hook is appeared when the snood gets entangled or the hook is sticked in the mainline.

  • PDF

Machinability investigation and sustainability assessment in FDHT with coated ceramic tool

  • Panda, Asutosh;Das, Sudhansu Ranjan;Dhupal, Debabrata
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.681-698
    • /
    • 2020
  • The paper addresses contribution to the modeling and optimization of major machinability parameters (cutting force, surface roughness, and tool wear) in finish dry hard turning (FDHT) for machinability evaluation of hardened AISI grade die steel D3 with PVD-TiN coated (Al2O3-TiCN) mixed ceramic tool insert. The turning trials are performed based on Taguchi's L18 orthogonal array design of experiments for the development of regression model as well as adequate model prediction by considering tool approach angle, nose radius, cutting speed, feed rate, and depth of cut as major machining parameters. The models or correlations are developed by employing multiple regression analysis (MRA). In addition, statistical technique (response surface methodology) followed by computational approaches (genetic algorithm and particle swarm optimization) have been employed for multiple response optimization. Thereafter, the effectiveness of proposed three (RSM, GA, PSO) optimization techniques are evaluated by confirmation test and subsequently the best optimization results have been used for estimation of energy consumption which includes savings of carbon footprint towards green machining and for tool life estimation followed by cost analysis to justify the economic feasibility of PVD-TiN coated Al2O3+TiCN mixed ceramic tool in FDHT operation. Finally, estimation of energy savings, economic analysis, and sustainability assessment are performed by employing carbon footprint analysis, Gilbert approach, and Pugh matrix, respectively. Novelty aspects, the present work: (i) contributes to practical industrial application of finish hard turning for the shaft and die makers to select the optimum cutting conditions in a range of hardness of 45-60 HRC, (ii) demonstrates the replacement of expensive, time-consuming conventional cylindrical grinding process and proposes the alternative of costlier CBN tool by utilizing ceramic tool in hard turning processes considering technological, economical and ecological aspects, which are helpful and efficient from industrial point of view, (iii) provides environment friendliness, cleaner production for machining of hardened steels, (iv) helps to improve the desirable machinability characteristics, and (v) serves as a knowledge for the development of a common language for sustainable manufacturing in both research field and industrial practice.

Research for robot kidnap problem in the indoor of utilizing external image information and the absolute spatial coordinates (실내 공간에서 이동 로봇의 납치 문제 해결을 위한 외부 영상 정보 및 절대 공간 좌표 활용 연구)

  • Jeon, Young-Pil;Park, Jong-Ho;Lim, Shin-Teak;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2123-2130
    • /
    • 2015
  • For such automatic monitoring robot or a robot cleaner that is utilized indoors, if it deviates from someone by replacement or, or of a mobile robot such as collisions with unexpected object direction or planned path, based on the planned path There is a need to come back to, it is necessary to tough self-position estimation ability of mobile robot in this, which is also associated with resolution of the kidnap problem of conventional mobile robot. In this study, the case of a mobile robot, operates indoors, you want to take advantage of the low cost of the robot. Therefore, in this paper, by using the acquisition device to an external image information such as the CCTV which is installed in a room, it acquires the environment image and take advantage of marker recognition of the mobile robot at the same time and converted it absolutely spatial coordinates it is, we are trying to solve the self-position estimation of the mobile robot in the room and kidnap problem and actual implementation methods potential field to try utilizing robotic systems. Thus, by implementing the method proposed in this study to the actual robot system, and is promoting the relevant experiment was to verify the results.

A Study of the Temperature Dependency for Photocatalytic VOC Degradation Chamber Test Under UVLED Irradiations (UVLED 광원을 이용한 광촉매 VOC 제거 특성 평가시 온도에 따른 농도 변화에 관한 연구)

  • Moon, Jiyeon;Lee, Kyusang;Kim, Seonmin
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.755-761
    • /
    • 2015
  • Photocatalytic VOCs removal test in gas phase is generally performed by placing the light source on the outside due to maintaining a constant temperature inside the test chamber. The distance between light source and photocatalysts is importantin the VOC degradation test since the intensity of light is rapidly decreased as the distance farther. Especially, for the choice of light source as UVLED, this issue is more critical because UVLED light source emits lots of heat and it is hard to measure the exact concentration of VOCs due to changed temperature in the test chamber. In this study, we modified VOC removal test chamber base on the protocol of air cleaner test and evaluated the efficiency of photocatalystunder UVLED irradiation. Photocatalystsof two different samples (commercial $TiO_2$ and the synthesized vanadium doped $TiO_2$) weretested for the p-xylene degradation in the closed chamber system and compared with each other in order to exclude any experimental uncertainties. During the VOC removal test, VOC concentrations were monitored and corrected at regular time intervals because the temperature in the chamber increases ${\sim}20^{\circ}C$ due tothe heat of UVLED. The results showed that theconversion ratio of p-xylene has 40~43% difference before and after the temperature correction. Based on those results, we conclude that the VOC concentration correction must be required for the VOC removal test in a closed chamber system under UVLED light source and obtained the corrected efficiencies of various photocatlysts.

Effect of an Aqueous Chlorine Dioxide Generator and Effect on Disinfection of Fresh Fruits and Vegetables by Immersion Washing (이산화염소수 생성기의 생성효율 및 과.채류에 대한 침지 세정 살균효과)

  • Park, Kee-Jai;Jeong, Jin-Woong;Lim, Jeong-Ho;Jang, Jae-Hee;Park, Hee-Joo
    • Food Science and Preservation
    • /
    • v.15 no.2
    • /
    • pp.236-242
    • /
    • 2008
  • We investigated the optimum concentration of a $NaClO_2$ solution and the amount of gaseous $Cl_2$ for production of high yield and purity of aqueous $ClO_2$ by use of a gaseous chlorine-chlorite $ClO_2$ generator. This system produced lower concentrations of chlorine dioxide and is applicable for direct-use in food processing as a cleaner and sanitizer. The concentration of $NaClO_2$ solution and the amount of gaseous $Cl_2$ was varied from 0.01-0.1% and 100-1,000 g/hr, respectively. The concentrations of chlorite, chlorate, FAC (free available chlorine), and chlorine dioxide that were produced increased with increasing concentration of $NaClO_2$ solution and with the amount of gaseous $Cl_2$. The optimum concentration of $NaClO_2$ solution and amount of gaseous $Cl_2$ were 0.1% and 900 g/hr respectively. $ClO_2$ and FAC produced at these concentrations were 882.0 ppm and 8.0 ppm, with no detection of chlorite and chlorate. The yield and purity of $ClO_2$ were 97.0% and 96.0% respectively. Immersion-cleaning experiments showed that this protocol decreased the level of CFU/g by $10^3$- to $10^4$-fold, with a similar effect on fruit.

Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities (소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로)

  • Shin, Hyejin;Park, Woosang;Kim, Bokyung;Ji, Kyunghee;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

Shear Bond Strength of Resin Cements on the IPS e.max Press (IPS e.max Press에 대한 수종 레진 시멘트의 전단결합강도에 관한 연구)

  • Lee, Kyung-Eun;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.311-322
    • /
    • 2010
  • The purpose of this study was to evaluate the bond strengths between IPS e.max Press and four different types of resin cements that often used for esthetic restoration. Disc shaped IPS e.max Press blocks(N=40, diameter: 12mm, thickness: 3mm) were fabricated according to the manufacture's instruction and cleaned with ultrasonic cleaner. They were embedded into an autopolymerizing acrylic resin. Fourty cylinder shaped resin block(Filtek Z350, diameter: 4.5mm, thickness: 3mm) were fabricated using a plastic tube. Each specimens were randomly divided into 4 experimental group and bonded each other using 4 different resin cements(Variolink II(light-cure), Variolink II(dual-cure), Calibra, Super-Bond C&B) according to the manufactures' recommendations. All the specimens were stored in normal saline at $37^{\circ}C$ for 24 hours before test. Universal testing machine at a crosshead speed of 1mm/min was used to evaluate the shear bond strength. The data were statistically analyzed using one-way ANOVA(P<.01). Multiple comparison was done by the Tukey HSD test. The shear bond strength of Super-Bond C&B to e.max was significantly lower than those of Calibra, Variolink II(light-cure), Variolink II(dual-cure) (P<.01). The shear bond strength of Calibra, Variolink II(light-cure), Variolink II(dual-cure) to e.max were not significantly different. The shear bond strengths of light-cure/dual-cure cement were higher than that of self-cure cement.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF