Analysis of New Air Control System in Clean Stocker (Clean Stocker내 새로운 방식의 기류제어에 관한 해석)

  • Choe, Gi-Han;Han, Chang-U;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Magnetic Levitated Electric Monorail System for Flat Panel Display Glass Delivery Applications (FPD 공정용 Glass 이송 시스템을 위한 자기부상 EMS의 개발)

  • Lee, Ki-Chang;Moon, Ji-Woo;Koo, Dae-Hyun;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.566-572
    • /
    • 2011
  • In recent semiconductor and FPD (Flat Panel Display) manufacturing processes, high clean-class delivery operation is required more and more for short working time and better product quality. Traditionally SLIM (Single-sided Linear Induction Motor) is widely used in the liner drive applications because of its simplicity in the rail structure. A magnetically levitated (Maglev) unmanned vehicle with SLIM traction, which is powered by a CPS (Contactless Power Supply) can be a high precision delivery solution for this industry. In this paper unmanned FPD-carrying vehicle, which can levitate without contacting the rail structure, is suggested for high clean-class FPD delivery applications. It can be more acceptable for the complex facilities composed with many processes which require longer rails, because of simple rail structure. The test setup consists of a test vehicle and a rounded rail, in which the vehicle can load and unload products at arbitrary position commanded through wireless communications of host computer. The experimental results show that the suggested vehicle and rail have reasonable traction servo and robust electromagnetic suspensions without any contact. The resolution of point servo errors in the SLIM traction system is accomplished under 1mm. The maximum gap error is ${\pm}0.25mm$ with nominal air gap length of 4.0mm in the electromagnetic suspensions. This type of automated delivery vehicle is expected to have significant role in the clean delivery like FPD glass delivery.

A Study on the Performance Improvement of the Air Washer System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 시스템의 성능개선을 위한 연구)

  • Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3413-3417
    • /
    • 2007
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. In the present study, an experiment was carried out to examine the improvement of removal efficiency for the gaseous contaminants. In order to improve the gas removal efficiency, a hot water contact heat exchanger was installed upstream of the air washer to heat and humidify the incoming outdoor air before entering the air washer.

  • PDF

An Analysis and Assessment of Transient Vibration Phenomenon for Precision Equipment Due to Adjacent Utility Operation in TFT-LCD Fab (TFT-LCD 생산공장 내 유틸리티 가동으로 인한 정밀장비 과도진동 현상 및 평가)

  • Baek, Jae-Ho;Lee, Hong-Ki;Son, Sung-Wan;Chun, Chong-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.726-735
    • /
    • 2007
  • Inside the factory buildings of aprecision industry (which produces semiconductors or TFT-LCD), thousands of vibration-sensitive precision equipments operate in the clean rooms. Various utility equipments that are installed around them for proper operation cause various sources of noise and of vibration to exist inside the clean rooms and thus deteriorate the noise and the vibration environment within. In this study, we check if the existing transient vibration phenomenon is caused by the vibrations that arise from operating the utility installed near these equipments; compare and evaluate the vibration criteria of precision equipments regarding the transient vibration phenomenon; and check the efficiency of these criteria.

Architectural Improvement plans in a quarantine system for Senior facilities (노인요양시설 방역을 위한 시설 개선 방안)

  • Kang, Jeeeun;Kwon, Soonjung;Lee, Hyunjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.61-69
    • /
    • 2021
  • Purpose: Senior long-term care facilities are vulnerable to a cluster infection because of frequent physical contact, large group dining, communal living, and room sharing. This study aims to provide architectural improvement plans for a quarantine system in the facilities. Methods: Actual quarantine action data, guidelines from governments and institutes, in-depth interviews with facility staff are analyzed. Results: To prevent a cluster infection in the senior facilities, it is necessary to provide an architectural plan focusing on increasing the number of single rooms and isolation rooms, providing isolation rooms for staff, separation of a soiled room from a clean room, planing an entry vestibule and a visitor's room. Implications: It is important to analyze the existing condition of facilities that had been going through cohort isolation and provide the architectural solution to strengthen infection control.

Characteristics of Contaminant Transfer in a Clean Space for the Location of Product and Fan Filter Unit (청정공간에서 제품과 팬필터유닛의 위치에 따른 오염물질의 전파 특성)

  • Kim, Hyouk-Soon;Noh, Kwang-Chul;Lee, Young-Koo;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.452-457
    • /
    • 2008
  • We performed a study on the contaminant transfer in a clean space for the location of product and fan filter unit using computational fluid dynamics analysis. To simplify the real product moving process, three different non-moving cases regrading the locations of product were selected: no product, at the lower side, and at the upper and lower sides. And to investigate the characteristics of the contaminant transfer, the arrangement of fan filter units was varied. Local mean air-age and contaminant distribution were used as evaluation indices. From the results, the contaminant transfer to the product was the most when the products were simultaneously located at the upper and lower sides. And the contaminant was easily exhausted regardless of the location of product when the fan filter units were properly arranged at the top side of the clean space.

  • PDF

A Study for the Establishment of Appropriate Facilities Criteria of the Korean Welfare Devices Center (한국형 복지용구사업소의 적정 시설기준 수립을 위한 기초 연구)

  • Chin, Young Ran;Bae, Joa Sup;Chung, Jae Wook;Lee, Hyo Young
    • 한국노년학
    • /
    • v.30 no.4
    • /
    • pp.1163-1177
    • /
    • 2010
  • This study was conducted to establish the appropriate facilities criteria of the Korean welfare devices center. We e-mail surveyed 194 welfare devices centers and analysed 13 blueprints of them. We established the following proper principles of facilities. First, consist type and area of room should depend on the type of welfare devices centers. Second, The flow of human and welfare devices should be simple. Third, the area calculated on the base of intent of center owner and the size of beds, wheelchairs, etc. Fourth, exhibit room facing with roadside may obtain advertising effect. Fifth, the storage and disinfecting room should use different entrance, and avoid the intersection of flow to prevent cross-contamination. Sixth, the access road to the exhibition and consulting room should be able to approach by the wheelchair. seventh, office room should be invisible to keep customer's privacy. Direct Cleaning-disinfecting type center on the premise that the maximum 165m2, middle 150m2, intermediate 140m2, display at least Consultation, Cleaning-disinfecting room, storage (clean, contaminated), the office, equipped with a parking space. Entrust Cleaning-disinfecting type center on the premise that a maximum 134m2, middle 119m2, intermediate 109m2 exhibited minimal activity room, consultation room, office, equipped with a parking space, collecting welfare when importing equipment warehouse (clean, pollution) have been proposed to equip up to.