• Title/Summary/Keyword: chromium

Search Result 1,440, Processing Time 0.025 seconds

Studies on Sericin Fixation by Use of Alum Meal (명반처리에 의한 견직물개선연구 -Sericin 정착을 중심으로 하여-)

  • 최병희;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.21 no.2
    • /
    • pp.11-19
    • /
    • 1979
  • This has been carried out how the sericin insoluble fixations of raw silk should be with potassium alum. This is learned from the leather tanning technique which the process works with collagen, a kind of proteins. Former reports had shown such works, however, they did not consider the moisture absorbability after their process reports by using chromium alum, formalin or vinyl acetate grafting. This report, however, paid attention to protect such absorbability as well as sericin fixation, so far it may be useful for plactical use of silk. In order to clear how the sericin is fixed with such chemicals, fundermental mechanism of weding process and chemical reaction against proteins were also discussed. The obtained results of the report are as followings. 1. Alum should not be treated for raw silk with high temperature bath like other reports because such treat induces raw silk to be stiffly after the treat. 2. It is recommended that raw silk should be treated with alum solution at room temperature for more than three hours. Even in this case, the use of only alum with raw silk could to fix sericin some how, but it increased the water proofness of the silk. 3. 1% of alum solution was found to be able to fix the sericin of raw silk. 4. In case we consider only sericin fixations, a combination treat of 1% alum for three hours and 0.5% NaOH for ten minutes method showed the best result. 5. In case we consider sericin insoluble fixation and moisture absorbility, the reversive combination of the above process was found to be the best results. 6. Sericin fixing evidence was shown with drying feature curves of wed each treated silk where we could to analyze how the chemical nature is changed after each treat. 7. Deguming ratio may be obtained up to 4.3% after the alum combination treat with regular raw silk. Such ratio was considered to be good enough for the purpose when the textile is washed with warm soap water. 8. Moisture absorbability of the combination treat of alum and NaOH was found to be good enough as well as non treated silk. 9. The tenacity and elongation of the treated silk did not change even after three month. 10. Above all, this method is considered to be better process than other coloured fixing (tannin method. Cr-alum method) or smell fixing (formalin method. vinyl acetate method).

  • PDF

The Role of Oxygen Free Radicals from Endothelial Cells in Endotoxin-induced Endothelial Cell Cytotoxity (내독소에 의한 혈관 내피세포 손상에서 혈관 내피세포로부터 유리된 산소기의 역할에 관한 연구)

  • Choi, Hyung-Seok;Jeong, Ki-Ho;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.319-327
    • /
    • 1994
  • Background: The pathogenetic mechanism of adult respiratory distress syndrome(ARDS) is not clearly defined yet, but it is well known that increased pulmonary capillary permeabilty is characteristic feature of ARDS. The increased alveolar-capillary permeability is usually preceded by damage of pulmonary artery endothelial cells. The released enzymes and oxygen free radicals from the activated neutrophils seem to play a predominant role in endothelial cell cytotoxicity. The activated neutrophils, however, probably are not the sole contributing factor in this type of damage because many cases of ARDS have been reported in severe neutropenia. Bacterial endotoxin perse and/or oxygen free radicals released from endothelial cells are suggested to be possible factors that contribute to the development of ARDS. The purpose of this study is to investigate the direct cytotoxicity of endotoxin and the role of oxygen free radicals released from the endothelial cells in endotoxin-induced endothelial cell cytotoxicity. Methods: First, to investigate whether endotoxin is cytotoxic to HUVE by itself, various doses of endotoxin were added to culture medium and cytotoxicity was measured. Second, to evaluate the possible role of oxygen free radical in endotoxin-induced HUVE cytotoxicity, various antioxidants were added on the endotoxin-induced HUVE cytotoxicity and cytotoxicity was measured. Third, to verify the release of oxygen free radicals from HUVE, the concentrations of hydrogen peroxide in the endotoxin-treated culture supernatant were measured. Finally, to observe the cytotoxic effect of hydrogen peroxide, HUVE cytotoxicity in the presence of various doses of hydrogen peroxide was measured. The fourth generations of subcultured HUVE from primary culture were used. The cell cytotoxicity was quantified by the chromium-51 release assay. Results: 1) Endotoxin alone showed HUVE cytotoxicity in a dose-dependent fashion. 2) Endotoxin-induced HUVE cytotoxicity was significantly attenuated by the pretreatment of catalase and DMTU. 3) Hydrogen peroxide was released from HUVE after endotoxin treatment in a dose-dependent fashion. 4) Exogenous hydrogen peroxide also showed HUVE cytotoxicity in a dose-dependent fashion. Conclusion: These results suggest that endotoxin alone can directly injure HUVE, and, oxygen-free radicals released from HUVE in response to endotoxin may also participate in the endotoxin-induced HUVE cytotoxicity.

  • PDF

Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions (염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도)

  • Yun, Kwi-Dug;Ryu, Su-Kyoung;Vang, Mong-Sook;Yang, Hong-So;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.151-157
    • /
    • 2010
  • Purpose: The purposes of this study was to evaluates shear bond strength between zirconia core and veneer-ceramic in order to examine the clinical practice of colored zirconia block fabricated by infiltration method into the metal chloride solution. Material and methods: CNU block and $Everest{(R)}$ ZS blank were used. VITA In-$Ceram{(R)}$2000 YZ Coloring liquid (LL1) and 3 aqueous metal chloride solutions containing chromium and molybdenum ingredients were used. 40 zirconia specimens were prepared into cuboid shape ($5{\times}5{\times}10 mm$). All specimens were divided into 5 groups by infiltrating into the coloring liquids. After that, porcelain was build up into the shape of $5{\times}5{\times}4mm^3$, followed by sintering. The maximum loading and shear bond strength was measured. Failure patterns and failure sites were examined. Results: 1. There were no statistical differences in shear bond strength between zirconia blocks (P > .05). 2. There were no statistically significant differences in shear bond strength between non-colored and colored zirconia blocks, while shear bond strength of non-colored zirconia blocks is higher than that of colored specimen (P > .05). 3. In the comparison with shear bond strength among colored zirconia blocks, there were no statistical differences according to kinds of coloring liquid (P > .05). 4. Mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. The veneering ceramic failure of all specimens was observed in either interface of zirconia or veneering ceramic. Conclusion: Shear bond strength between colored zirconia and veneering ceramic shows lower tendency than non-colored zirconia, but there was clinically allowable value.

A STUDY OF NI-RESISTANT BACTERIA ON THE RESTORED STAINLESS STEEL CROWN (기성금관 수복어린이에서의 니켈내성균에 관한 연구)

  • Chung, Sat-Byul;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.274-282
    • /
    • 2000
  • Stainless steel crowns are widely used for restoration for primary molars. The material used for the crowns is an alloy of $70\sim80%$ nickel and $5\sim15%$ chromium. Nickel has been known to cause allergic reaction, cancer and cell toxicity. Little is known about nickel with respect to the relationship between Ni-contained SS crown and graining of Ni-resistance in oral microorganisms. The purpose of this study is to examine whether use of Ni-contained SS crown leads to occurrence of Ni-resistant microorganism, especially enterococci. The gingival crevicular fluid of two different groups was taken. Experimental group included patients wearing SS crown, and control group comprised individuals without SS crown. The samples were plated in BHI agar, BHI agar supplemented with nickel chloride at the concentration of 3mM and bile esculin azide (BEA) agar. The cultured enterococci on BEA agar medium were tested their Ni-resistance in nickel-containing media increasing concentrations from 3mM to 50mM. The results were as follows: 1. In experimental group, a total of 507,350 strains were isolated on BHI agar, of which 53,864(10.62%) strains were found to be resistant to 3mM nickel. In control group, of 414,590 isolates on BHI agar, 37,523 isolates were resistant to 3mM nickel. 2. A total of 95 enterococci were isolated on BEA agar in experimental group, while 20 were isolated in control group. of the enterococci, 68 and 12 isolates were found to be nickel-resistant in experimental and control group, respectively. 3. Of 68 nickel-resistant isolates in experimental group, one survived 50mM nickel. In contrast, none of the isolates in control group was observed to grow at the concentrations over 30mM nickel.

  • PDF

Development of soil certified reference material for determination of the hazardous elements (유해원소 측정용 토양 인증표준물질 개발)

  • Kim, In-Jung;Min, Hyung-Sik;Suh, Jung-Ki;Han, Myung-Sub;Lim, Myung-Chul;Kim, Young-Hee;Shin, Sun-Kyoung;Cho, Kyung-Haeng
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • A certified reference material (CRM) of KRISS 109-03-SSD was developed for the analysis of hazardous elements in soil. The target elements were As, Cd, Cr, Cu, Hg, Ni, Pb, Zn being regulated by the Soil Environment Conservation Act. Starting material was collected from tailing dump of an unworked tungsten mine at Sangdong (Gangwon-do, Korea). The starting material under-went through a series of fabricating process steps of screening, drying, grinding, sieving, blending, bottling, sterilization and was certified according to the ISO Guide 35. Isotope dilution-inductively coupled mass spectrometry (ID-ICP/MS) and instrumental neutron activation analysis (INAA) were used for the measurement. Homogeneity was tested according to ISO 13528 annex B. The certified values were determined using the results from two different methods or from two independent measurements using a method. Finally, certified values of seven elements of arsenic, cadmium, chromium, copper, lead, nickel and zinc were determined. Mercury did not satisfied the criteria of homogeneity and the result would be provided for information only, together with iron and tungsten. It was also studied, the extractable fraction of elements by aqua regia according to the ISO 11466 protocol being frequently studied for the purpose of environmental monitoring. It was performed as a inter-laboratory study by 6 laboratories of a public institute and universities. Standard deviation among the laboratories was much bigger than the uncertainty of the certified value. The result of inter-laboratory study on the extractable fraction will be provided for information, only.

A Study on Hygiene and Safety of Sanitary Wet Towel (물수건의 위생실태 및 안전성 연구)

  • Kim, Young-Sug;Kim, Yang-Hee;Kim, Young-Su;Kim, Dae-Hwan;Ryu, Kyong-Shin;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.4
    • /
    • pp.258-263
    • /
    • 2016
  • The risks of sanitary indicative bacteria, heavy metals and chlorinated derivatives in 94 cases of sanitary wet towels used in food services (39 from sanitary wet towel treatment business, 55 from food services) were assessed in the present study. Lead was detected in the range of N.D.~0.41 mg/kg (75 cases were not detected), N.D.~0.25 mg/kg of arsenic (93 cases were not detected), N.D.~0.01 mg/kg of cadmium (7 cases were lower than limit of quantitation; 87 cases were not detected), 0.003 mg/kg ~ 0.09 mg/kg of mercury. And chromium (VI) was not detected from all samples. The level of lead was the highest among the tested heavy metals, and the highest concentration of lead was 0.41 mg/kg. However, it was only 2.1% of legal limit (less than 20 mg/kg). The average moisture content of the samples was 61.9% (50.0% ~ 77.0%) and it showed no relevance to the detection of bacterial counts. Escherichia coli was not detected. Bacterial counts were detected 43 cases and among them, 24 cases were exceeded the legal limit. It was verified that the packaging conditions of sanitary wet towel (whether it is packed by a piece or not and sealed or not) are critical factors to cause the germ contamination and cross contamination in the wet towels. The chlorinated derivatives (chlorites and chlorates) were detected in 17 (19.3%) out of 88 cases. The results would be used as preliminary information to establish the programs of "Safety education for manufacturers and public policy of safety".

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA (한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究))

  • Chang, Ik-Tae;Yang, Jae-Ho;Kim, Chang-Whe;Kim, Kwang-Nam;Lee, Sun-Hyung;Kim, Yung-Soo;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

Improvement on Fish Odor of Extracts from Salmon Frame Soaked in Soybean Milk (두유 전처리에 의한 열수추출 연어 Frame 엑스분의 비린내 개선)

  • Heu, Min-Soo;Park, Shin-Ho;Kim, Hye-Suk;Kim, Hyung-Jun;Han, Byung-Wook;Ji, Seong-Gil;Kim, Jeong-Gyun;Yoon, Min-Seok;Kim, Jin-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.2
    • /
    • pp.223-230
    • /
    • 2008
  • For the use of extracts from salmon frame as a basic material of Gomtang-like products, various methods (soaking into soybean milk, adding anchovy, and adding spices) for masking fish odor into extracts from salmon frame were examined and the food component characteristics were also compared with commercial Gomtang. According to the results of volatile basic nitrogen, transmission at 660 nm and sensory evaluation of extracts, soaking treatment, which is the soaking of salmon frame into soybean milk, was the most efficient method among the various methods for masking fish odor into extracts from salmon frame. There was no difference in the proximate composition between extracts from salmon frame soaked (FS) and unsoaked (C) into soybean milk. The FS was not detected in heavy metals, such as chromium, lead and cadmium. The taste value of FS (16.26) was higher than that of C and the major amino acids were glutamic acid and aspartic acid. Total amino acid content of FS (3.08 g/100 mL) was also higher than those of C (2.95 g/100 mL) and commercial Gomtang (1.70 g/100 mL), and the major amino acids were glycine, proline, glutamic acid and arginine. The calcium and phosphorus contents of FS/500 mL accounted for 21.7% and 18.5%, respectively, of the recommended daily allowance of mineral for adult.

Leaching of Chromium, Copper and Arsenic in Soils and Rapid Identification of CCA-Treated Woods Using Modified PAN Stain (CCA 목재방부제 설치지역 토양의 크롬.구리.비소 분포와 PAN 지시약을 이용한 CCA 방부목의 현장 검출방법 개발)

  • Abdelhafez, Ahmed A.;Awad, Yasser M.;El-Azeem, Samy A.M. Abd;Kim, Min-Su;Ham, Kwang-Joon;Lim, Kyoung-Jae;Yang, Jae-E;Ok, Yong-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.1
    • /
    • pp.60-67
    • /
    • 2010
  • Although several studies have reported that Cr, Cu and As can leach from CCA-treated woods, few studies have been conducted on this topic in Korea. Therefore, this study was conducted to monitor Cr, Cu and As leaching from CCA-treated wood products and to develop a rapid identification method for CCA-treated wood products by using indicators such as PAN stain. Soil samples were collected at depths of 0-70 cm and wood samples were collected by thickness of wood layer. The soil and wood samples were then digested and analyzed for Cr, Cu and As concentrations using an atomic absorption spectrometer. The As and Cu concentrations decreased sharply with depth from 34.38 and 33.65 mg $kg^{-1}$ at 0-1 cm to 1.72 and 7.84 mg $kg^{-1}$ at 70 cm, respectively. In general, As was more mobile than Cr and Cu in the soil. For wood samples, the Cr, Cu and As concentrations were higher in the outer layer (0-0.5cm) than the inner layers (0.6-4.5cm). Evaluation of rapid identification methods revealed that 100% acetone with 0.1% PAN indicator was the best combination for detection of CCA-treated wood in the field.