• 제목/요약/키워드: chromaticity coordinates

검색결과 84건 처리시간 0.035초

소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

요분석 스트립의 정색반응에 대한 색도좌표 보정 (The Compensation of Chromaticily Coordinates on Primary Color Reaction of Urine Strips)

  • 김재형;조진욱;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs, the spectral reflectance of a urine strip, and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

요분석 스트립의 정색반응에 대한 색도좌표 보정 (The Compensation of Chromaticity Coordinates on Primary Color Reaction of Urine Strips)

  • 김재형;조진욱;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs. the spectral reflectance of a urine strip. and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

석탄폐석을 이용한 소다라임계 컬러유리의 광학적 특성 (Optical Properties of Soda-lime Color Glass Fabricated by Using Refused Coal Ore)

  • 임태영;정상수;황종희;김진호;김정국
    • 한국재료학회지
    • /
    • 제20권10호
    • /
    • pp.524-534
    • /
    • 2010
  • Glass was fabricated using refused coal ore obtained from the Dogye coal mine in Samcheok. We additionally used soda ash and calcium carbonate to make a glass with the chemical composition of soda-lime glass, and we also used white, brown, and green glass cullet to make various kinds of colored glass. Transparent glass was fabricated by melting batch materials including refused coal ore at $1550^{\circ}C$ for 1 hr in an electrical furnace. The light transmittance and color chromaticity were measured by a UV/VIS/NIR spectrometer. Transparent glass with a light transmittance of over 80% was fabricated using normal refused coal ore and white glass cullet. Various kinds of colored glass with a light transmittance of 30-80% were fabricated using refused coal ore and brown or green glass cullet. The light transmittance of the mixed color glass samples, fabricated using normal refused coal ore and brown glass cullet and green glass cullet, indicated 30-47%, a relatively low value, in the condition of a cullet ratio of 20-50%. The characteristics of the color chromaticity of the glass samples were indicated in a chromaticity diagram by x-coordinates, y-coordinates, Y (lightness). The values of x-coordinates and y-coordinates were moved with a regular directional property according to the kind and amount of glass cullet. Therefore, we concluded that refused coal ore can be used for raw materials of color glass products like art glass and glass tile.

Effects of Current Modulation Conditions on the Chromaticity of Phosphor Converted (PC) White LEDs

  • Kim, Seungtaek;Kim, Jongseok;Kim, Hyungtae;Kim, Yong-Kweon
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.449-456
    • /
    • 2012
  • For two well-known modulation methods, stepwise current modulation (SCM) and pulse width modulation (PWM), the effects of driving current modulation conditions on chromaticity were experimentally investigated in a white LED lighting system. For the experimental implementation of both SCM and PWM, a white LED lighting was fabricated using phosphor converted (PC) white light emitting diodes (LEDs) and a driving circuit module was developed. By using them, the variations of illuminance, color coordinates, and spectrum were evaluated under various forward current conditions. Through the analysis in color coordinates, yellow shift in SCM and blue shift in PWM were observed on chromaticity diagrams with increasing average driving current. In addition, in order to analyze color deviation quantitatively, color distance before and after current increase, and the correlated color temperature (CCT) were calculated. As a result, for the white LED lighting in both modulation conditions, the maximum difference in the calculated CCT was obtained close to 1000 K. It means that careful consideration is required to be taken in the design of illumination systems to avoid serious problems such industrial accidents.

역 삼자극치 알고리즘을 이용한 LED램프 디지털 광색제어시스템 (Digital Light Color Control System of LED Lamp using Inverse Tri-Stimulus Algorithm)

  • 강신호;이정민;염정덕
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, the method to calculate chromaticity coordinate from spectral power distribution of LED is presented. Also, inverse tri-stimulus algorithm to find mixed luminance of red, green, blue LED from targeted luminance and chromaticity coordinate is proposed. Besides, digital light color control system of LED lamp applied this algorithm has been developed. In experiments, each chromaticity coordinate of red, green, blue LED calculated from this algorithm has relative percentage error of few % to measured values. Digital code is drawn from inverse tri-stimulus algorithm, and measured values of luminance and chromaticity coordinate of LED lamp digitally controlled by this code also have relative percentage error within a few % to targeted luminance and chromaticity coordinate.

xy 색도좌표 표현을 위한 방송 조명용 LED 신경망 제어기 (Neuro-controller for Broadcast Lighting LED to Express xy Chromaticity Coordinates)

  • 박성찬;박진현
    • 한국정보통신학회논문지
    • /
    • 제24권6호
    • /
    • pp.706-713
    • /
    • 2020
  • 기존 방송용 LED 조명 제어방법은 RGB LED에 3자극치 이론을 적용한 LED 전류제어를 사용한다. 제어의 편의성을 위해 이러한 제어방법은 1차 선형함수로 근사하거나 시행착오를 통해 적절한 값을 사용한다. 그리고 실제 방송 조명에서 요구되는 충분한 광량과 색 혼합을 위해 적용되는 확산 판 등을 사용하지 않아 방송 조명으로는 적합하지 않다. 본 연구에서는 방송 조명용 LED 패널 제어방법으로 비선형함수 근사 능력이 뛰어난 순방향신경망을 사용하여 원하는 색도좌표 값과 조도의 디밍 값에 맞는 RGBW LED 패널 제어기를 구현하고자 한다. 성능 평가 결과 xy 색도좌표의 오차가 대부분 ±0.02 이내이며, ANSI C78.377A의 허용범위를 만족하였다. xy 색도좌표 값의 평균 오차는 xerror=0.0044, yerror=0.0030로 제안한 알고리즘의 우수함과 안정적인 성능을 확인하였다.

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Silicate 형광체 증가에 대한 발광 특성 및 신뢰성 분석 (Analysis for luminescence property about an increase quantity of silicate phosphor and reliability)

  • 윤양기;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권4호
    • /
    • pp.275-285
    • /
    • 2012
  • This paper presents a changes of luminescence property for converted white LEDs with the commercially available silicate phosphor. If silicate phosphor's quantity increase step by step. luminescence property will be changing. we analyze luminescence property for these change and carry out the high temperature aging test for 7,000 hours, the high temperature and humidity aging test for 7,000 hours for reliability. LED degradation not only results in reduced light output but also in color changes. so we monitor correlated color temperature (CCT), chromaticity coordinates(x, y) and spectrum intensity. Those results suggest that humidity factor more bad effect in color changes than temperature factor and Lighting quality is related with quantity of phosphor.