• Title/Summary/Keyword: chip solution

Search Result 276, Processing Time 0.026 seconds

Development of Automatic Nutrient-Solution Controller Using Single-chip Microcomputer (원칩 마이크로 컴퓨터를 이용한 양액 자동 조제 장치의 개발)

  • 오길근;류관희;홍순호;김효중
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 1995
  • This study was conducted to develop an automatic nutrient control system for trickle application of nutrient solution. Temperature, electric conductivity(EC). pH and dissolved oxygen(DO) were selected as control variables. A controller using single-chip microcomputer was constructed. An automatic control system for nutrient solution and a controller using single-chip microcomputer with control algorithm were developed. The control system was tested, and could control temperature, EC and pH within the error ranges of $pm 0.2^{circ} pm 0.2mS/cm, pm 0.1pH$, respectively.

  • PDF

Determination of stress state in chip formation zone by central slip-line field

  • Andrey Toropov;Ko, Sung-Lim
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.577-580
    • /
    • 2003
  • Stress state of chip formation zone is one of the main problems in metal cutting mechanics. In two-dimensional case this process is usually considered as consistent shears of work material along single of several shear surfaces. separating chip from workpiece. These shear planes are assumed to be trajectories of maximum shear stress forming corresponding slip-line field. This paper suggests new approach to the constriction of slip-line field, which Implies uniform compression in chip formation zone. On the base of given model it has been found that imaginary shear line in orthogonal cutting is close to the trajectory of maximum normal stress and the problem about its determination have been considered. It has been shown that there is a second central slip-line field inside chip, which corresponds well to experimental data about stress distribution on tool rake face and tool-chip contact length. The suggested model could be useful in solution of various problems of machining.

  • PDF

Development of Microfluidic Polydiacetylene Sensor Chip for pH detection (pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발)

  • Hwang, Hyun-Jin;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF

Leaching Behavior of Gold from CPU chip Grinding Products in Iodide/Iodine Solution (Iodide/Iodine용액에서 CPU chip 분쇄물의 금 침출특성)

  • Jung, Insang;Joe, Aram;Choi, Joonchul;Song, Youjin;Park, Poongwon;Park, Kyungho;Lee, Sujeong;Park, Jaikoo
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.3-9
    • /
    • 2016
  • The leaching behavior of gold from waste CPU chip using Iodide/Iodine solution was studied. The direct leaching of gold with Iodide/Iodine solution for CPU chip under the size of 150 mesh showed leaching ratio of 20%. It was assumed that the copper film was produced on the gold particle during grinding process and the copper film prevents lodine/Iodide solution from contacting with leachable gold. Meanwhile, the extraction of gold was improved to 90% by pretreatment process with $HNO_3$ solution. In order to explain the result, EDS and ICP analysis for the leaching residue were conducted. It was found that the copper coated on the surface of the gold particle was removed about 80% by $HNO_3$, resulting in the increment of gold leaching rate.

Web Server Application in The Operation of Chip Mounter (Chip Mounter 운영에서 Web Server 활용)

  • 임선종;김선호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.172-175
    • /
    • 2003
  • The enterprise find a solution to the problems such as a reduction of manufacturing period, accurate analysis for customer demand, improvement for customer service and rise of manufacture accomplishment. Internet is a good solution to such problems. Internet offers WWW(World Wide Web), remote control, file transfer and e-mail service. Among the services, WWW takes large portion because of convenient GUI, easy information search and unlimited information registration. Remote Monitoring Server(RMS) system that uses network service is constructed for chip mounter. Hardware base consists of RMS, chip mounter and C/S(Customer Service) server. Software includes DBMS and various modules in server home page. This provide product number, bad product number, trouble code, content and countermeasure in real-time information module, user information in setup module, detailed error information in fault diagnosis module, fault history in fault history module and customer information in customer service management module.

  • PDF

A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG (ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구)

  • Kang, Bum-Sun;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

Development of a Signal Conditioning Circuit for Capacitive Displacement Sensors Using a Commercial Single Chip Solution (상용 Single Chip Solution을 이용한 정전용량형 변위 센서 신호 처리 모듈 개발)

  • Kim J.A.;Kim J.W.;Eom T.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.31-32
    • /
    • 2006
  • A signal conditioning circuit for capacitive sensors was developed using a commercial single chip solution. Since capacitive displacement sensors can achieve high resolution and linearity, they have been widely used as precision sensors within the range of several hundred micrometers. However, they inherently have a limitation in low frequency range and some nonlinearity characteristics and so a specially designed signal conditioning circuit is needed to handle these properties. Up to now, several companies already have succeeded in the development of the capacitive sensors system and they are commercially available in the market. In this research, to construct the signal processing circuits more easily and simply, we used a universal LVDT signal conditioner (AD698). Since the AD698 provides one chip solution for a basic signal processing including modulation and demodulation using various internal components, we can build the processing circuits successfully with minimal additional circuits: a compensation circuits for the drift caused by the bias current of OP amplifiers and a fine adjustment circuit for the elimination of nonlinearity. The signal processing circuits shows nonlinearity less than 0.05% in the comparison with a laser interferometer.

  • PDF

A Single-Chip Video/Audio CODEC for Low Bit Rate Application

  • Park, Seong-Mo;Kim, Seong-Min;Kim, Ig-Kyun;Byun, Kyung-Jin;Cha, Jin-Jong;Cho, Han-Jin
    • ETRI Journal
    • /
    • v.22 no.1
    • /
    • pp.20-29
    • /
    • 2000
  • In this paper, we present a design of video and audio single chip encoder/decoder for portable multimedia application. The single-chip called as video audio signal processor (VASP) consists of a video signal processing block and an audio single processing block. This chip has mixed hardware/software architecture to combine performance and flexibility. We designed the chip by partitioning between video and audio block. The video signal processing block was designed to implement hardware solution of pixel input/output, full pixel motion estimation, half pixel motion estimation, discrete cosine transform, quantization, run length coding, host interface, and 16 bits RISC type internal controller. The audio signal processing block is implemented with software solution using a 16 bits fixed point DSP. This chip contains 142,300 gates, 22 Kbits FIFO, 107 kbits SRAM, and 556 kbits ROM, and the chip size is $9.02mm{\times}9.06mm$ which is fabricated using 0.5 micron 3-layer metal CMOS technology.

  • PDF

Diagnostic Paper Chip for Reliable Quantitative Detection of Albumin using Retention Factor (체류 인자를 이용한, 알부민의 정량 분석용 종이 칩)

  • Jeong, Seong-Geun;Lee, Sang-Ho;Lee, Chang-Soo
    • KSBB Journal
    • /
    • v.28 no.4
    • /
    • pp.254-259
    • /
    • 2013
  • Herein we present a diagnostic paper chip that can quantitatively detect albumin without external electronic reader and dispensing apparatus. We fabricated a diagnostic paper chip device by printing wax barrier on the paper and wicking it with citrate buffer and tetrabromophenol blue to detect albumin in sample solution. The paper chip is so simple that we dropped a sample solution at sample pad and measure the ratio of two travel distances of the sample solvent and albumin under the name of retention factor. Our result confirmed that the retention factor was constant in the samples with same concentration of albumin and useful determinant for the measurement of albumin concentration. The paper chip is affordable and equipment-free, and close to ideal point-of-care test in accordance with the assured criteria, outlined by the World Health Organization. We assume that this diagnostic paper chip will expand the concept of colorimetric determination and provide a inexpensive diagnostic method to aging society and developing country.

A Colorimetric Glucose Assay via Concentration Gradient Paper Chip (종이기반 농도 구배 형성 칩을 통한 포도당 발색 반응 검사)

  • Kim, Taehoon H.;Shin, Hyun Young;Lee, Yun-Il;Tae, Ki-Sik;Kim, Minseok S.
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.302-307
    • /
    • 2017
  • This paper presents a paper-based concentration gradient chip to analyze colorimetric glucose assay. The paper-based concentration gradient chip was fabricated through a wax patterning technique that can design the fluidic channel by selectively printing hydrophobic and hydrophilic areas. Afterwards, glucose and dilution solutions were loaded into the inlet of a concentration gradient chip and each solution was then mixed sequentially at mixing channel. Finally, concentration gradient was formed at each outlet of the chip. To measure the glucose concentration of the solution in outlets, we conducted colorimetric glucose assay with fixed concentration of glucose solution (0, 5, 10, 15 and 20 mM) and obtained normalized intensity. Subsequently, glucose concentrations of the outlets were calculated by substituting the normalized intensity to linear regression function based on the normalized intensity of fixed glucose concentration. Finally, the concentration gradient of glucose was formed on the chip with the result of colorimetric assay. The concentration gradient paper chip has the potential to accurately analyze unknown glucose concentration.