• 제목/요약/키워드: chemical shift artifact

검색결과 9건 처리시간 0.019초

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

MRI Artifacts

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.51-57
    • /
    • 1997
  • MRI의 artifact는 대부분 신호의 부호화 방향에 따라서 방향성을 가지는데, 이를 요약해보면, 위상부호화 방향의 artifact에는 motion artifact, flow artifact, RF noise등이 있고, 주파수 부호화 방향의 artfact는 susceptibility artfact, chemical shift artifact, central line artifact등이 있으며, 양방향 모두 생길수 있는 것은 Aliasing artifact와 Gibb's phenomenon이고, 전체적으로 영샹의 질을 떨어뜨리는 것은 susceptibility artifact, Eddy current, cross talk등이 있다. 이런 artifact는 대부분은 MRI 자체의 물리적 특성에 다소간 기인하므로, artifact가 없는 양호한 영상을 얻기 위해서는 MRI의 설치 단계부터 관심이 필요하고, MRI의 기본원리와 다양한 artifact에 대해 이해함으로써, 제거 가능한 artifact는 제거하여 양질의 영상을 만들고 판독시의 오류를 피할 수 있도록 해야할 것이다.

  • PDF

CHESS 기법을 이용한 지방소거 경추 자기공명영상에서 자화감수성 인공물을 줄이기 위한 연구 (A Study on the Reduction of the Magnetic Susceptibility Artifact in MRI of the Cervical Spine with Chemical Shift Selective Fat Suppression)

  • 임우택;정홍량
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.197-198
    • /
    • 2014
  • CHESS(chemical shift selective saturation) 기법을 이용한 경추 자기공명영상에서 주로 나타나는 자화 감수성 인공물(susceptibility artifact)을 줄이기 위한 보조물질을 찾고자 하였다.

  • PDF

화학적이동이 자기공명영상에 미치는 영향 (The Effect of Chemical Shift on MR Imaging)

  • 김경민;김영진
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.19-23
    • /
    • 1996
  • 정상조직과 지방조직의 화학적 결합의 차이는 화학적 이동 artifact를 발생시킨다. 이러한 화학적 이동으로 생긴 결과는 주로 공명신호 위치의 부정확으로 나타나지만 횡적완화시간의 변화도 일으키게 된다. 물분자 수소원자핵의 횡적완화시간 T$_2$ 과 지방분자 수소원자핵의 횡적완화시간 T$_{2}$$^{*}$ 를 신호대 잡음비, 신호응답도, 그리고 영상시간에 각각 넣어 비교해 보았다. 그 결과 신호대 잡음비와 신호응답도는 각각 약 5%와 8%가 감소하였고, 영상시간은 약 10% 가량 증가하였다. 따라서, 화학적 이동은 영상의 왜곡 외에도 영상과정의 효율을 저하시킴을 알았다.

  • PDF

Parameters Affecting India Ink Artifacts on Opposed-Phase MR Images

  • Kim, Bo Ra;Ha, Dong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.341-350
    • /
    • 2019
  • Purpose: To determine the MR parameters affecting India ink artifacts on opposed-phase chemical shift magnetic resonance (MR) imaging. Materials and Methods: The use of a female Sprague-Dawley rat was approved by our Institutional Animal Care and Use Committee. Using an iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) images, which is a modified Dixon method, axial opposed-phase images of the abdominal cavity were obtained with different MR parameters: series 1, different repetition times (TRs; 400, 2000, and 4000 ms); series 2, different echo times (TEs; 10, 50, and 100 ms); series 3, different field of views (FOVs; 6, 8, 16, and 24 cm); series 4, different echo train lengths (ETLs; 2, 4, and 8); series 5, different bandwidths (25, 50, and 85); and series 6, different slice thicknesses (1, 2, 4, 8, and 16 mm). Artifacts on opposed images obtained with different parameters were compared subjectively by two radiologists. For objective analysis, the thickness of the artifact was measured. Spearman's correlation between altered MR parameters and thicknesses of India ink artifact was obtained via objective analysis. Results: India ink artifact was increasingly apparent using shorter TE, larger FOV and ETL, and thicker slices upon subjective analysis. The objective analysis revealed a strong negative correlation between the thickness of the artifact and TE (r = -0.870, P < 0.01); however, strong positive correlations were found between FOV (r = 0.854, P < 0.01) and slice thickness (r = 0.971, P < 0.01). Conclusion: India ink artifact was thicker with shorter TE, larger FOV, and larger slice thickness.

GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구 (Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.531-537
    • /
    • 2016
  • 물과 지방에서 발생하는 화학적 이동의 인공물을 확인하기 위해 다양한 MRI parameter를 적용하여 실험하였다. MRI의 1.5T와 3.0T에서 parameter와 bandwidth 및 부호화 변화에 따른 영상을 스캔하여 SNR, CNR을 비교하였다. MRI 영상에서 물과 기름의 화학적 이동의 인공물의 발생을 확인할 수 있었고, 3.0T보다 1.5T에서의 영상이 인공물이 비교적 줄어드는 것을 확인할 수 있었다. Bandwidth의 폭이 넓어짐에 따라 인공물이 줄어드는 것을 확인할 수 있었다. 따라서 MRI검사에서 화학적 이동의 인공물을 감소하기 위해서는 주 자장의 세기가 약하고, bandwidth의 폭을 넓히는 것이 적절할 것으로 생각된다.

HMQC vs HSQC for Small Molecules

  • Kim, Eunhee;Cheong, Hae-Kap
    • 한국자기공명학회논문지
    • /
    • 제21권4호
    • /
    • pp.131-134
    • /
    • 2017
  • Proton detected Heteronuclear Multiple Quantum Coherence (HMQC) and Heteronuclear Single Quantum Coherence (HSQC) essentially provide the same information - correlation of the chemical shift of the proton to J-coupled hetero nuclei such as $^{13}C$ or $^{15}N$ nuclei. This paper is a practical note for the students who ask which one is better and which methods they use routinely. Artifact suppression using phase cycling and gradient pulses are discussed.

복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교 (Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2016
  • 본 연구의 목적은 복부 자기공명영상에서 주로 적용되고 있는 4 종류의 펄스시퀀스를 중심으로 1.5 T 와 3.0 T 기기의 자기장의 차이로 나타나는 자기장의 속성 및 인공물 발생 차이를 비교하기 위해 분석을 하였다. PACS network로 전송된 총 500 명의 데이터를 정량적으로 SNR 값을 분석하였고, MSA, CSA, DA을 3 단계로 구분하여 정성적 평가를 하였다. 정량적 평가에서 SNR 값은 1.5 T 값 보다 의미 있는 결과로 높은 값을 얻었지만(p<0.05), 영상의 인공물이 발생하여 영상의 질을 저하시키는 요인도 있었다(p<0.05). 1.5 T는 3.0 T 보다 인공물 발생이 적어 3.0 T 만큼에 영상의 질을 보상 할 수가 있었다(0.05). 결론적으로, 이러한 결과를 토대로 자기장의 차이에 따라 발생되는 자기장의 속성 및 인공물 발생 차이를 파악 할 수 있었으며 이에 따른 대처방안을 제공할 수 있었다. 향후 임상현장에서 두 기기를 이용하여 복부 자기공명영상을 검사 할 때 환자를 직접 검사하는 MRI 사용자에게 가이드라인이 될 것이다.

견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구 (A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor)

  • 박의철;배석환;류연철;박영준;김용권
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.513-519
    • /
    • 2021
  • 봉합 나사못을 이용한 견관절 수술 환자들의 예후를 확인하기 위하여 MRI(Magnetic Resonance Imaging)를 이용하여 추적검사를 시행한다. 봉합나사못을 삽입한 경우에는 임상적 관찰을 용이하게 하기 위하여 지방소거법을 이용한 영상촬영 기법이 이용되는데, 이때 이용되는 지방 신호 억제 기법으로 CHESS(Chemical Shift Selective), STIR(Short Tau Inversion Recovery), Dixon 기법 등이 주로 이용되고 있다. 봉합나사못은 비자성 재료를 이용해서 제작되지만, 환부에 삽입되는 티타늄 재질의 금속물질은 비자성체임에도 불구하고 국소자장을 왜곡시켜 결과 영상의 기하학적인 왜곡은 물론 심각한 영상신호의 감소 현상을 발생시킨다. 봉합나사못을 삽입하여 환부를 관찰하는 경우에는 뼈 혹은 뼈 인접 부위의 영상을 획득하여야 하는데 뼈와 주변 조직의 임상적 관찰을 위해서는 뼈의 지방 신호를 억제할 필요가 있다. 이때 이용되는 지방 신호 억제 기법은 금속 삽입물로 인한 자기장 불균일의 영향을 받는다. 본 연구에서는 3가지 지방억제 영상기법(CHESS, STIR, Dixon)을 이용하여 금속물질을 삽입한 환자로부터 영상을 획득하여 비교, 분석하였으며, 그 결과로 봉합나사못을 삽입한 환자의 병변 관찰 및 수술 후 예후를 관찰하기 위한 영상기법으로 STIR 영상기법이 가장 적합함을 알 수 있었다. 연구 결과에 따르면 금속 물질을 인체에 삽입한 환자의 경우, 지방 신호 억제가 필요한 MRI 검사에서는 STIR 기법을 이용하는 것이 임상적 가치가 높은 영상을 얻을 수 있을 것이다.