• Title/Summary/Keyword: chemical resistance test

Search Result 578, Processing Time 0.022 seconds

Evaluation on the Properties of Modified-sulfur Concrete as a Basic Study for Development of Anti-corrosive Concrete (내부식성 콘크리트 개발을 위한 기초연구로서 개질유황 혼합 콘크리트의 물성 평가)

  • Park, Sang-Soon;Na, Ok-Jung
    • Corrosion Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.28-37
    • /
    • 2016
  • Due to the increased construction of offshore concrete structures and the use of de-icing salts for the purpose of snow removal, the needs for the development of anti-corrosive concrete are increasing. To solve these problems, an evaluation of the mechanical and durability properties for concrete were conducted by mixing modified-sulfur as 0 %, 5 %, 10 %, 15 % cement weight ratio. Both strengths and the properties affecting durability such as water absorption coefficient, chloride ion permeability, accelerated carbonation resistance, rapid freezing and thawing, and chemical resistance were evaluated. All evaluations performed were according to the test specifications associated KS. The results indicate that mixing of modified-sulfur lowed chloride ion permeability and improved chemical resistance.

Evaluation of Fracture Detection Function for the FRP by Electrical Resistance Measurement (전기저항 측정에 의한 FRP의 파괴 예측 기능의 평가)

  • Sin, Sun-Gi;Kim, Yeong-Hui;Lee, Jun-Hui
    • Korean Journal of Materials Research
    • /
    • v.12 no.2
    • /
    • pp.135-139
    • /
    • 2002
  • Carbon powders (CP) and carbon fiber (CF) were introduced info glass fiber reinforced plastics (FRP) composites to obtain fracture detection function. The composites were evaluated through the relation between a load-displacement curve and an electrical resistance change curve in three point bending test. CP containing FRP (CP-FRP) has a sensitivity of electrical resistance change at much lower load level than CF containing FRP (CF-FRP). In loading-unloading tests, CP-FRP showed a large amount of residual electrical resistance which enables the estimation of loading hysteresis.

Improvement of the Wear Resistance of PP using Montmorillonite

  • Kim, Jae June;Ryu, Sung Hun;Oh, Jin Young
    • Elastomers and Composites
    • /
    • v.57 no.2
    • /
    • pp.40-47
    • /
    • 2022
  • The effects of maleic-anhydride-grafted polypropylene (PP-g-MAH) and montmorillonite (MMT) on the wear resistance of polypropylene (PP) were investigated. The surface of MMT was modified with 3-aminopropyltriethoxysilane, and the interfacial interaction between PP and MMT was improved using PP-g-MAH. Fourier-transform infrared spectroscopy was used to confirm that silane was grafted on the surface of MMT. The Taber abrasion test and scanning electron microscopy were used to determine the wear resistance and observe the surface morphology of PP, respectively, after wear testing. Energy-dispersive X-ray spectroscopy was used to compare the effects of PP-g-MAH and silane modification of MMT on the dispersion of MMT. The results indicated that silane was successfully grafted onto the surface of MMT. Moreover, the wear resistance of PP was improved by the addition of MMT. The wear resistance of PP composites comprising silane-modified MMT and PP-g-MAH was higher than those of other PP composites. This was attributed to silane improving the interfacial interaction between MMT and PP.

A Study on Design of Dry Floor Tile Unit Method System (바닥타일 건식공법용 수지매트 개발에 관한 연구)

  • 김상미;조상영;김성식;임남기;정병훈;김무성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.22-27
    • /
    • 2001
  • The purpose of this study is development of dry floor tile method that practically used for improving wet method's defect, with resin mat design. PE resin used mat which satisfied with bonding test, waterproof test, resistance to chemical attack test, resistance to impact test and freezing and thawing test is confirmed the basic property.

  • PDF

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Heat and Crack Resistance of Natural Rubber(NR) Compounds According to the Type of Antioxidants (산화방지제 종류에 따른 천연고무 배합물의 내열성 및 내크랙성)

  • Roh, Jong-Dae;Shin, Jun-Geun;Kim, Jin-Tae;Hur, Jae-Young;Kim, Won-Ho
    • Elastomers and Composites
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 1999
  • In this study, heat and crack resistance of natural rubber (NR) compounds was evaluated. To prevent the effects of the crosslinking system, a conventional vulcanization system was selected, where the accelerator/sulfur ratio was fixed to 0.25. Vulcanizates containing phenylenediamine showed high tensile strength and tear strength compared to other vulcanizates because phenylenediamine can cause additional crosslinking and high dispersion In the vulcanizates. In the pure shear test, vulcanizates containing phenylenediamine showed an excellent tearing energy which was due to the irregular crack path, and showed excellent heat and crack resistance which was also due to the good dispersity of antioxidant and additional crosslinks in the rubbber vulcanizates.

  • PDF

Assessment of Fungal Growth Resistance in Silicone Sealants According to Test Methods (시험법에 따른 실리콘 실란트의 곰팡이 저항성 평가)

  • Ahn, Myung-Su;Choi, Sung-Hyun;Lee, Ki-Hyang;Nah, Changwoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.43-53
    • /
    • 2024
  • This research undertook the assessment of six types of silicone sealants prepared. Their resistance to fungi was evaluated according to ASTM G 21, LH specification(LHCS 41 40 12), and the newly instituted KS F ISO 21265 test methods. The findings showed that KS F ISO 21265 test method exhibited the superior discriminative capability in assessing fungal resistance when compared to ASTM G 21 and LH specification(LHCS 41 40 12) test methods. Additionally, it was confirmed that oxime curing sealants demonstrated higher fungal resistance than alkoxy curing sealants. Furthermore, The introduction of a condition to assess fungal resistance after 4 weeks of immersion at 50℃ in KS F ISO 21265 is expected to enable long-term fungal resistance evaluation of sealants.

Study on Properties with Different Plasticizers in the Preparation of Polymer Compounds for Cable Sheath

  • Li, Xiang Xu;Lee, Sang Bong;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • v.54 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Four different polymer compounds were prepared from four kinds of plasticizers, viz. di-2-ethylhexyl azelate (DOZ), di-2-ethylhexyl adipate (DOA), di-2-ethylhexyl sebacate (DOS), and di-2-butyl sebacate (DBS), for making cable sheaths for ships. Ethylene-vinyl acetate and ethylene-propylene-diene-copolymer as matrix polymers and ethylene-vinyl acetate grafted maleic anhydride as a coupling agent were compounded with a flame retardant, crosslinking agent, filler, and other additives, besides the plasticizer to obtain the polymer compounds. The polymer containing DOZ showed the highest MH and ${\Delta}T$ in the rheology test, while that containing DBS was found to have the lowest tensile strength and highest elongation because of low ${\Delta}T$. The four polymers showed similar values (31.7-31.9) for flame resistance, while the polymer containing DOZ showed the highest value for cold resistance.

Chemical Resistance Characteristics of Concrete Surface Coating Agent with Flexibility (유연성을 갖는 콘크리트 표면보호재의 내화학적 특성)

  • Han, Sang-Hoon;Yoon, Ju-Yong;Lee, Byung-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • The purpose of this study is evaluate the ability of coating materials developed in order to prevent the durability deterioration of the concrete structure. Neutralization test, freezing and thawing test, and sulfate resistance test were performed in this study. Test results show that the developed coating material is effective against durability deterioration.

Characterization of Reverse Osmosis Membrane Surface Modified by Silane-epoxy Using UV (UV를 적용한 역삼투막의 실란-에폭시 표면 개질 및 특성 평가)

  • Park, Hee Min;Yang, Won Yong;Lee, Yong Taek
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.169-179
    • /
    • 2018
  • The purposes of this paper were to improve both fouling and chlorine resistance by increasing the hydrophilicity of the reverse osmosis membrane. In order to improve chlorine resistance, the surface of RO membrane was activated by ultraviolet irradiation, and then it was modified by the sol-gel method using Octyltriethoxysilane (OcTES) such as the silane coupling agent to low sensitivity to chlorine, thereby the polyamide active layer was protected and chlorine resistance was improved. In addition, polyglycerol polyglycidyl ether (PGPE) and sorbitol polyglycidyl ether (SPE) coating with different number of epoxides, ring opening reaction of epoxide improved the anti-fouling resistance. The surface modification condition was optimized by FT-IR, XPS, and contact angle analysis. As a result, the permeability reduction rate of the silane-epoxy modified membrane after the fouling test was decreased about 1.5 times as compared with that of the commercial membrane. And the salt rejection was maintained over 90% at $20,000ppm{\times}hr$ even after chlorine resistance test.