• 제목/요약/키워드: chemical ionization

검색결과 409건 처리시간 0.029초

Identification of triacylglycerols in coix seed extract by preparative thin layer chromatography and liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry

  • Sim, Hee-Jung;Lee, Seul gi;Park, Na-Hyun;Kim, Youna;Cho, Hyun-Woo;Hong, Jongki
    • 분석과학
    • /
    • 제30권2호
    • /
    • pp.102-111
    • /
    • 2017
  • Here we reported a methodology for identification of triacylglycerols (TAGs) and diacylglycerols (DAGs) in coix seed by preparative thin layer chromatography (prep-TLC) and non-aqueous reversed-phase liquid chromatography (NARP LC)-atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). Lipid components were extracted from coix seed by reflux extraction using n-hexane for 3 hr. TAGs and DAGs in coix seed extract were effectively purified and isolated from matrix interferences by prep-TLC and then analyzed by LC-APCI-MS and MS/MS for identification. TAGs were effectively identified taking into consideration of their LC retention behavior, APCI-MS spectra patterns, and MS/MS spectra of $[DAG]^+$ ions. In MS/MS spectra of TAGs, diacylglycerol-like fragment $[DAG]^+$ ions were useful to identify TAGs with isobaric fragment ions. Based on an established method, 27 TAGs and 8 DAGs were identified in coix seed extract. Among them, 15 TAGs and 8 DAGs were for the first time observed in coix seed. Interestingly, some of TAGs isolated by prep-TLC were partly converted into DAGs through probably photolysis process during storing in room temperature. Thus, degradation phenomenon of TAGs should be considered in the quality evaluation and nutritional property of coix seed. LC-APCI-MS/MS combined with prep-TLC will be practical method for precise TAG and DAG analysis of other herbal plants.

A Study on the Band Structure of ZnO/CdS Heterojunction for CIGS Solar-Cell Application

  • Sim, Hana;Lee, Jeongmin;Cho, Seongjae;Cho, Eou-Sik;Kwon, Sang Jik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.267-275
    • /
    • 2015
  • In this paper, ZnO films were prepared by atomic layer deposition (ALD) and CdS films were deposited using chemical bath deposition (CBD) to form ZnO/CdS heterojunction. More accurate mapping of band arrangement of the ZnO/CdS heterojunction has been performed by analyzing its electrical and optical characteristics in depth by various methods including transmittance, x-ray photoemission spectroscopy (XPS), and ultraviolet photoemission spectroscopy (UPS). The optical bandgap energies ($E_g$) of ZnO and CdS were 3.27 eV and 2.34 eV, respectively. UPS was capable of extracting the ionization potential energies (IPEs) of the materials, which turned out to be 8.69 eV and 7.30 eV, respectively. The electron affinity (EA) values of ZnO and CdS calculated from IPE and $E_g$ were 5.42 eV and 4.96 eV, respectively. Energy-band structures of the heterojunction could be accurately drawn from these parameters taking the conduction band offset (CBO) into account, which will substantially help acquisition of the full band structures of the thin films in the CIGS solar-cell device and contribute to the optimal device designs.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Rapid separation and identification of 31 major saponins in Shizhu ginseng by ultra-high performance liquid chromatography-electron spray ionization-MS/MS

  • Sun, Ting-Ting;Liang, Xin-Lei;Zhu, He-Yun;Peng, Xu-Ling;Guo, Xing-Jie;Zhao, Long-Shan
    • Journal of Ginseng Research
    • /
    • 제40권3호
    • /
    • pp.220-228
    • /
    • 2016
  • Background: Among the various ginseng strains, Shizhu ginseng is endemic to China, mainly distributed in Kuandian Manchu Autonomous County (Liaoning Province, China); however, not much is known about the compounds (especially saponins) in Shizhu ginseng. Methods: A rapid, sensitive, and reliable ultra-high performance liquid chromatography coupled with MS/MS (UHPLC-MS/MS) method was developed to separate and identify saponins in Shizhu ginseng. Results: The separation was carried out on a Waters ACQUITY UPLC BEH $C_{18}$ column ($100mm{\times}2.1mm$, $1.7{\mu}m$) with acetonitrile and 0.1% formic acid aqueous solution as the mobile phase under a gradient elution at $40^{\circ}C$. The detection was performed on a Micromass Quattro Micro API mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 31 saponins were identified or tentatively characterized by comparing retention time and MS data with related literatures and reference substances. Conclusion: The developed UHPLC-MS/MS method was suitable for identifying and characterizing the chemical constituents in Shizhu ginseng, which provided a helpful chemical basis for further research on Shizhu ginseng.

A Comprehensive Identification of Synaptic Vesicle Proteins in Rat Brains by cRPLC/MS-MS and 2DE/MALDI-TOF-MS

  • Lee, Won-Kyu;Kim, Hye-Jung;Min, Hye-Ki;Kang, Un-Beom;Lee, Cheol-Ju;Lee, Sang-Won;Kim, Ick-Young;Lee, Seung-Taek;Kwon, Oh-Seung;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권9호
    • /
    • pp.1499-1509
    • /
    • 2007
  • Proteomic analyses of synaptic vesicle fraction from rat brain have been performed for the better understanding of vesicle regulation and signal transmission. Two different approaches were applied to identify proteins in synaptic vesicle fraction. First, the isolated synaptic vesicle proteins were treated with trypsin, and the resulting peptides were analyzed using a high-pressure capillary reversed phase liquid chromatography/tandem mass spectrometry (cRPLC/MS/MS). Alternatively, proteins were separated by two-dimensional gel electrophoresis (2DE) and identified by matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF/MS). Total 18 and 52 proteins were identified from cRPLC/MS-MS and 2DE-MALDI-TOF-MS analysis, respectively. Among them only 2 proteins were identified by both methods. Of the proteins identified, 70% were soluble proteins and 30% were membrane proteins. They were categorized by their functions in vesicle trafficking and biogenesis, energy metabolism, signal transduction, transport and unknown functions. Among them, 27 proteins were not previously reported as synaptic proteins. The cellular functions of unknown proteins were estimated from the analysis of domain structure, expression profile and predicted interaction partners.

MeOH-DMSO 혼합용매중에서 tert-butyl halide의 이온화에 미치는 용매효과 (Study of Solvent Effects on the Ionization of tert-butyl Halide in MeOH-DMSO Mixtures)

  • 사공열;김시준;김진성;이본수
    • 대한화학회지
    • /
    • 제29권1호
    • /
    • pp.45-51
    • /
    • 1985
  • MeOH-DMSO 혼합용매중에서 t-butyl halide의 가메탄올 분해반응 속도상수 및 활성화 파라미터를 전기전도도법으로 측정하였고, Taft의 분광용매화 변수인 용매의 극성-편극성(${\pi}^{\ast}$), 수소결합주기산도(${\alpha}$) 및 수소결합 받기염기도(${\beta}$)를 분광법에 의해서 5가지의 지시약을 이용하여 측정계산하였다. 분광용매화변수와 반응속도상수로부터 얻은 활성화파라미터를 써서 용매의 부피조성비에 따른 가용매분해반응의 속도상수 변화를 논의한 결과, t-butyl halide의 이온화에 용매의 ${\pi}^{\ast}$, ${\alpha}$${\beta}$가 협동적으로 기여했고, 또한 이탈기와 혼합용매사이의 이온-쌍극자 작용과 수소결합주기-받기 작용과 같은 독특한 상호작용이 전이상태의 안정화에 미치는 가장 중요한 용매효과 인자들임을 밝혔다.

  • PDF

Quantitative Analysis of Lysophosphatidic Acid in Human Plasma by Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Yoon, Hye-Ran;Pyo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권8호
    • /
    • pp.1139-1143
    • /
    • 2002
  • Analysis of lysophosphatidic acids (LPAs) is of clinical importance as they can serve a potential marker for ovarian and other gynecological cancers and obesity. It is critically important to develop a highly sensitive and specific method for the early detection of gynecological cancers to improve the overall outcome of this disease. We have established a novel quantification method of LPAs in human plasma by negative ionization tandem mass spectrometry (MS-MS) using multiple reaction monitoring (MRM) mode without the conventional TLC step. Protein-bound lipids, LPAs in plasma were extracted with methanol : chloroform (2:1) containing LPA C14:0 as an internal standard under acidic condition. Following back extraction with chloroform and water, the centrifuged lower phase was evaporated and reconstituted in methanol. The reconstituted solution was directly injected into electrospray source of MS/MS. For MRM mode, Q1 ions selected were m/z 409, 433, 435, 437 and 457 which corresponds to molecular mass [M-H]- of C16:0, C18:2, C18:1, C18:0 and C20:4 LPA, respectively. Q2 ions selected for MRM were m/z 79, phosphoryl product. Using MS/MS with MRM mode, all the species of LPAs were completely separated from plasma matrix without severe interferences. This method allowed simultaneous detection and quantification of different species of LPAs in a plasma over a linear dynamic range of 0.01-25 ㎛olL-1 . The detection limit of the method was 0.3 pmol/mL, with a correlation coefficient of 0.9983 in most LPAs analyzed. When applied to the plasmas of normal and gynecological cancer patients, this new method differentiated two different groups by way of total LPA level.

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.

Determination of oestrone, $17{\alpha}$-and $17{\beta}$-oestradiol in bovine aqueous humor using gas chromatography-negative ion chemical ionization mass spectrometry

  • Zafar-Iqbal;Midgley, John-M;Watson, David-G
    • Archives of Pharmacal Research
    • /
    • 제20권3호
    • /
    • pp.247-252
    • /
    • 1997
  • Perfluorotolyl (PFT)-ether and perfluorotoly-trimethylsilyl (PFT-TMS) ether derivatives of oestrone, $17{\alpha}$- and $17{\beta}$oestradiol were prepared under phase transfer conditons. The former derivatives under negative ion chemical ionization conditions gave significant ions in the mass spectrometer but $17{\alpha}$- and $17{\beta}$ -oestradiol gave poor resolution. However, the PFT-TMS derivatives of 17.${\alpha}$- and$17{\beta}$-oestradiol showed good resolution. These derivatives were used for the analysis of oestrogens in bovine aqueous humour, vitreous humour and retina. The mean $({\pm}SEM)$ concentrations of oestrone in bovine aqueous humour (n=18), vitreous humour (n=18) and bovine retina (n=4) were $0.47{\pm}0.11$, $0.46{\pm}0.14$ and $1.10{\pm}0.24 ng.ml^{-1}$, respectively. $17{\alpha}$-Oestradiol was detected in 16 out of 18 samples of bovine aqueous humour and vitreous humour and the mean $({\pm}SEM)$ concentrations were $0.30{\pm}0.10$ and $0.08{\pm}0.02 ng.ml^{-1}$, respectively. The mean $({\pm}SEM)$ concentration of 17.betha.-oestradiol in aqueous humour (n=7) and vitreous homour (n=11) $0.83{\pm}0.26 ng ml^{-1}$ and $0.39{\pm}0.09 ng ml^-1$, respectively. In retina the concentrations of both steroids were below the detection limit.

  • PDF

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.