The Fabrication and Test of a Phase-change Type Micropump (상변화 구동 방식 마이크로 펌프의 제작 및 시험)

  • Sim, U-Yeong;Lee, Sang-U;Yang, Sang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.6
    • /
    • pp.360-366
    • /
    • 2000
  • This paper presents the fabrication and test of a micropump consisting of a pair of Al flap valves and a phase-change type actuator. The actuator is composed of a heater, a silicone rubber diaphragm and a working fluid chamber. The diaphragm is actuated by the vaporization and the condensation of the working fluid. The micropump is fabricated by the anisotropic etching, the boron diffusion and the metal evaporation. The forward and the backward flow characteristics of the flap valves illustrate the appropriateness as a check valve. Also, the flow rate of the micropump is measured. When the square wave input voltage of 8 V, 70% duty ratio and 2 Hz is applied to the heater, the maximum flow rate of the micropump is $97\muell/min$ for zero pressure difference.

  • PDF

Development of Backflow prevented Micropump (역류방지형 유리계 마이크로 펌프 개발)

  • Choi J. P.;Cho K. C.;Kim H. Y.;Kim B. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.229-232
    • /
    • 2005
  • This paper presents the design and fabrication of backflow prevented Micropump using the metal membrane. The Micropump is consisted of the lower plate, metal membrane, upper plate and the piezoelectric-element. The lower plate includes the micro channel and the inlet, outlet of the Micropump. The upper plate includes the micro channel and connects the piezoelectric-element. These plate are fabricated on the Pyrex glass wafer by sandblasting process. The metal membrane does roll of check valve that is prevented backflow of the Micropump. The metal membrane is fabricated on the stainless steel by laser machining. Piezoelectric-element is actuated the Micropump and controlled flowing of fluid. The Micropump is fabricated by bonding process of these multi-layer.

  • PDF

Case of Improving Design by Using Analysis Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델을 활용한 개선설계 사례)

  • Dae Kyung Noh;Dong Won Lee;Taek June Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • This study aims to develop a Korean dental chair hydraulic circuit by improving the existing equipment in order to localize foreign leading companies' products. The suggested Hydraulic circuit can be applicable to varied sectors where height and backrest angle control of chair-type equipment are required. The study followed the steps below. First, three kinds of foreign hydraulic circuits were analyzed and three kinds of Korean dental chair hydraulic circuits were suggested. Second, it was determined whether the three kinds of Korean hydraulic circuits operate normally through SimulationX, a software specialized in multi domain analysis, and the effectiveness of each circuit was examined.

A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language (언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교)

  • Noh, Bokyung;Ban, Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • This research is about alternative measure of main components for sprinkler system like automatic wet pipe sprinkler system, dry pipe sprinkler system, pre-action sprinkler system, vacuum sprinkler system, deluge sprinkler system, and so on. By replacing the alarm check valve, dry valve, pre-operated valve, and deluge open valve with a solenoid valve, it be can be simplifed the various processes of the manufacturing process into one process, it creates an environment in which one standardized product can be produced simultaneously on a single machine. Therefore, it could improve the price competitiveness of products, reduce the maintenance cost, and help the adaptability of new sprinkler systems in the future. There is a benefit when it comes to apply to sprinkler system. Only replace the valve which is used to control primary and secondary valve such as wet, dry, pre operated, vacuum, deluge system valve. Other components such as retarding chambers, automatic air compressors, accelerators or adjusters, supervisory panels, vacuum pumps, and manual starters can be used as they are, so they can be easily applied to existing sprinkler system. It is needed to legal and institutional study for solenoid valve applied sprinkler system to commercialize.

Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate (전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

Laser Process of Polymer Micro Fluidic Devices (레이저 가공 폴리머 마이크로 유체 장치)

  • Kim, Joo-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.129-137
    • /
    • 2006
  • Polymer micro-fluidic devices were fabricated with laser processes. A UV laser and a femto laser were used to machine polymer micro-fluidic structures directly. This laser direct machining process suits the need of rapid prototyping, as in many applications changes from the original design are often required. As examples, two polymer micro-systems were developed: a micro-check valve and a micro diffuser pump. The micro fluidic devices can be applied for many applications such as clinical diagnostics and drug delivery. Advantages and disadvantages using polymers as a material for micro-fluidic applications are discussed.

Recycling of Safety Check Valves Contaminated with Radioactivity by Chemical Decontamination (化學除染에 의한 逆止밸브의 再使用)

  • 정종헌;최왕규;원휘준;심준보;오원진
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2001
  • Chemical decontamination techniques have been employed to reuse the high cost check valves contaminated with radioactivity and to reduce the radiation exposure during the inspection and maintenance work of safety injection system containing check valves. After chemical decontamination, an ultrasonic treatment was conducted to remove the fine solid particles retained in the crevices of check valves. The decontamination process conditions and the amount of chemical reagents were determined from the results of a pre-test, using the (list arm holder. The decontamination factors (DF), estimated from the activity in the solution, ranged from 14.5 to 18.5 corresponding to the activity removal of 93-95ft. The corrosion test data indicated that the general corrosion rate during a chemical decontamination-ultrasonic treatment process are low for type 304 S tainless steel, Inconel -600 and Stellite-6 materials $ (2.1\times10^{-2}$ $6.0\times10^{-2}$ and$ 1.7\times10^{-2}$ mil, respectively).

  • PDF

Immobilized Condition of Suchwowces cerevisiae for Ethanol Production from Persimmon Juice. (감 즙으로부터 에탄을 생산을 위한 Saccharomyces cerevisiae의 고정화 조건)

  • 이상원;손미예;서권일
    • Food Science and Preservation
    • /
    • v.6 no.2
    • /
    • pp.221-227
    • /
    • 1999
  • The immobilized culture system of Saccharomyces cerevisiae was examined to improve the efficiency of vinegar production from persimmon juice. Optimum concentration of Na-alginate for the immobilization was 2%. When the 1eakage of yeast from get beads was checked by turbidity of culture medium with varying concentration of Na-alginate from 1 to 4%, turbidity of culture medium increased from 8 hrs of cultivation with 1% Na-alginate concentration showing optical density of 0.82 at 20 hrs. However, the increase in turbidity of culture medium was slow with 2-4% Na-alginate showing optical density of 0.55-0.58 at 20 hrs. Microscopical analysis of gel matrix showed that the immobilized yeast was grown well regardless of Na-alginate concentration. Optimum size of gel bead and amount of inoculation were 2-3 m and 33mg, respectively. For ethanol production aerobic cultivation for 121hrs using cohen plug followed by anaerobic cultivation using silicon plug equipped with a check valve was the most effective.