• Title/Summary/Keyword: characteristics of down

Search Result 2,265, Processing Time 0.039 seconds

The Natural Cooling Effects of Pre-heated Substrate during RF Magnetron Sputter Deposition of ZnO (ZnO 박막의 RF 마그네트론 스퍼터 증착 중 미리 가열된 기판의 자연냉각 효과)

  • Park, Sung-Hyun;Lee, Neung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.905-909
    • /
    • 2007
  • Crystalline and micro-structural characteristics of ZnO thin films which were deposited on p-Si(100) with cooling naturally down of pre-heated substrate during RF magnetron sputter deposition, were investigated by XRD and SEM in this paper. The film which was prepared on the substrate which was pre-heated to $400^{\circ}C$ before deposition and then cooled naturally down during deposition, showed the most outstanding c-axis preferred orientation. The ZnO thin film having the best crystalline result were applied to SMR type FBAR device and resonance properties of the device were investigated by network analyzer. It showed that resonance frequency was 2.05 GHz, return loss was -30.64 dB, quality factor was 3169 and electromechanical coupling factor was 0.4 %. This deposition method would be very useful for application of surface acoustic wave filter or film bulk acoustic wave resonator.

Characteristics of centrifugal pump according to the shape of impeller (임펠러 형상에 따른 원심펌프의 특성)

  • Kim, S.Y.;Kim, Y.T.;Nam, C.D.;Lee, Y.H.;Kang, H.K.;Kim, S.D.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.43-44
    • /
    • 2005
  • The effect of break down of centrifugal pump due to entrained air has not been clarified yet. Thus, air-water two-phase flow experimental apparatus was installed to clarify the effect of break down. The performance results of a single-phase flow satisfied reappearance. Also, the heads coincided well impeller types.

  • PDF

Filtration Performance Evaluation of Low Flow Rate Filters by Beta Prime Theory (베타 프라임 이론에 의한 저유량 필터의 성능 평가)

  • Lee, Jae-Cheon
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.115-121
    • /
    • 2000
  • The contaminant seperation performance of fitters has been widely investigated for many years. However, most of the proposed filter assessment techniques have proven disappointing for practical use. Although the Multipass (Beta) Filtration test method (ISO 4572) provides valuable information in assessing fi ters, it has a limitation on evaluating the increasing family of low-flow and high Beta filters. The limitation stems from two main sources: the over simplified theoretical model and the inherently complicated procedure in analysis of data. Hence a new advanced filtration theory, the Beta Prime developed on a draw-down test basis is applied to predict field operating characteristics of a filter for tractor hydraulic systems in this study.

  • PDF

Cutting Condition Selection for Geometrical Accuracy Improvement in End Milling (엔드밀 가공에서 형상 정밀도 향상을 위한 절삭 조건 선정)

  • 류시형;최덕기;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1784-1788
    • /
    • 2003
  • For the improvement of geometrical accuracy in end milling, cutting method and cutting condition selection are investigated in this paper. As machining processes are composed of several steps such as roughing, semi-finishing. and finishing, cutting forces and tool deflection are calculated considering surface shape generated by the previous cutting. The effects of tool teeth numbers, tool geometry, and cutting conditions on the form error are analyzed. Using the from error prediction method from tool deflection, cutting condition for geometrical accuracy improvement is discussed. The characteristics and the difference of generated surface shape in up and down milling are dealt with and over-cut free condition in up milling is presented. The form error reduction method by alternating up and down milling is also suggested. The effectiveness of the presented method is examined from a set of cutting tests under various cutting conditions. This research contributes to cutting process optimization for the geometrical accuracy improvement in die and mold manufacture.

  • PDF

Measurement of two dimensional oil film thickness in piston by induced fluorescence method (유기형광법을 이용한 피스톤 유막두께의 이차원적 측정)

  • 민병순;최재권
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Thermal response of porous media cooled by a forced convective flow (강제대류에 의해 냉각되는 다공물질의 열응답 특성)

  • 백진욱;강병하;현재민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.600-609
    • /
    • 1998
  • The experimental investigation of thermal response characteristics by the air flow through the porous media has been carried out. The packed spheres of steel or glass were considered as the porous media in the present study. Temperature distributions of the fluid in the porous media as well as pressure drops through the porous media were measured. The transient temperature variations in the porous media are compared favorably with the analytical results in the high Reynolds number ranges. However, in the low Reynolds number ranges, the experimental data deviate from the analytical results, due to the dominant heat conduction penetration to the upstream direction, which is not considered in the analytical model. The cool-down response of porous media is found to be dependent upon the specific dimensionless time considering the material property and air velocity. The heat discharge process is recommended to be operated until a certain time, considering the cost efficiency.

  • PDF

The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Performance test (열상장비용 스터링 극저온 냉동기 특성평가 (I) : 성능시험)

  • 박성제;홍용주;김효봉;김양훈;이성래;이기백;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.320-323
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the cooling capacity / applied input power and cool down time are investigated. This cooler delivers approximately 0.9W cooling at 80K for 30W ~ 40W of input power. And, It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$.

  • PDF

Design of a Rceiver MMIC for the CDMA Terminal (CDMA 단말기용 수신단 MMIC 설계)

  • 권태운;최재하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • This paper presents a Receiver MMIC for the CDMA terminal. The complete circuit is composed of Low Noise Amplifier, Down Conversion Mixer, Intermediate Frequency Amplifier and Bias circuit. The Bias circuit implementation, which allows for compensation for threshold voltage and power supply voltage variation are provided. The proposed topology has high linearity and low noise characteristics. Results of the designed circuit are as follows: Overall conversion gain is 28.5 dB, input IP3 of LNA is 8 dBm, input IP3 of down conversion mixer is 0 dBm and total DC current consumption is 22.1 mA.

  • PDF

Wave Transformation near the Surfzone on the Arbitrary Beach Profile (불규칙한 수심단면에서 쇄파대 부근의 파고변형)

  • Choi, Han-Kyu;Gang, Jang-Su;Lee, Cheol-Eung
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.261-275
    • /
    • 1997
  • The objective of this paper is to develop two numerical model for predicting the wave height with set-up/down near the surfzone on a arbitrary beach profile. Two wave models, regular wave model and random wave model, are based on the energy flux equation with the energy dissipation effects. The developed numerical models are verified by comparison of numerical results with analytical solutions that are derived under the simple conditions. The characteristics of parameters included in each model are then investigated and decided to the range of behaviour by the sensitivity analysis. For sensitivity analysis, we carried out total 46 laboratory tests. Finally, the developed numerical models are applied to the field where the wave height near the surfzone has been measured. From the applications of numerical models, it is concluded that the developed numerical models may accurately predict the wave height with the set-up/down near the surfzone on a arbitrary beach profile.

  • PDF

Machine Constants of 30 kVA Superconducting Synchronous Motor (30kVA 초전도 전동기의 기기상수)

  • Choi, Kyeong-Dal;Hahn, Song-Yop;Tsukiji, Hiroshi;Hoshino, Tsutomu;Muta, Itsuya
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.34-36
    • /
    • 1996
  • For the test of the operating characteristics as a moor, a 20 kVA super conducting synchronous machine with rotating field windings has been made in Saga university, Japan from 1991. Before the load tests of it as a motor, we carried out cooling down tests and measured its machine constants. During the cooling down tests, we found that the rotor itself had no cryogenic problem, but the inlet part for liquid He had one. Though enough liquid He couldn't be accumulated inside the rotor because of this problem, we drove field currents up to 20 A and could acquire the machine constants and V curves of the super-conducting synchronous motor.

  • PDF