• 제목/요약/키워드: change of load

검색결과 2,499건 처리시간 0.03초

자동차 쇽업소버의 피로해석에 관한 연구 (A Study on Fatigue Analysis of Automotive Shock Absorber)

  • 조재웅;한문식
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.92-97
    • /
    • 2008
  • The safety and the durability of the shock absorber as an automotive chassis part under the fatigue load can be predicted in this study. The fatigue life becomes constant from 0.5 to 0.75 at the change of load which is the amplitude load divided by average load. But its life is sharply decreased at the change of load from 0.75 to 1.5. The influence of fatigue life according to the change of load can be predicted by these results. As the value of maximum damage is 9.61 at the middle part of upper side on shock absorber under the concentrated load, there is the greatest possibility of destruction at this part. The spring of shock absorber becomes nearly the state of pure shear and the uniaxial or biaxial stress exists at the rest part of it under the fatigue load.

비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 - (A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field -)

  • 최동호;최순군;김민경;허승오;홍성창;엽소진;윤광식
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.

기온변화에 의한 수요변동을 고려한 단기 전력수요예측 전문가시스템의 연구 (A study on the short-term load forecasting expert system considering the load variations due to the change in temperature)

  • 김광호;이철희
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.187-193
    • /
    • 1995
  • In this paper, a short-term load forecasting expert system considering the load variation due to the change in temperature is presented. The change in temperature is an important load variation factor that varies the normal load pattern. The conventional load forecasting methods by artificial neural networks have used the technique where the temperature variables were included in the input neurons of artificial neural networks. However, simply adding the input units of temperature data may make the forecasting accuracy worse, since the accuracy of the load forecasting in this method depends on the accuracy of weather forecasting. In this paper, the fuzzy expert system that modifies the forecasted load using fuzzy rules representing the relations of load and temperature is presented and compared with a conventional load forecasting technique. In the test case of 1991, the proposed model provided a more accurate forecast than the conventional technique.

  • PDF

전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안 (Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability)

  • 이윤환;김태균;김지훈;이병준;강부일;조종만
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.

응력확대계수측정을 위한 하중에 의한 자속밀도변화의 이론적 해석 (Theoretical Analysis of Change in Magnetic Flux Density Due to Load for Measuring KI)

  • 이정희
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.367-371
    • /
    • 2003
  • In order to determine the effective way of measuring the Mode I stress intensity factor for a material containing a two-dimensional surface crack by means of the alternating current potential drop(ACPD) technique, the change in magnetic flux density between crack surfaces and above the specimen surface due to load was studied theoretically. The magnetic flux density in the air between crack surfaces is uniform and above the specimen surface is not changed by increasing the load in the material. Therefore, the change in potential drop due to load in a measuring system which was designed to induce a large amount of electro-motive force was caused by the change in internal inductance of material, the change in the mutual inductance between internal inductance of material and measuring system and the change in the mutual inductance between internal inductance of material and power supply line.

  • PDF

수질오염총량관리 배출부하량에 대한 강우영향 분석연구 (Rainfall Effects on Discharged Pollution Load in Unit Watershed Area for the Management of TMDLs)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.648-653
    • /
    • 2010
  • Discharged pollution load for the management of Total Maximum Daily Loads (TMDLs) is calculated on the basis of rainfall data for reference year. Rainfall has an influence on discharged pollution load in unit watershed with combined sewer system. This study reviewed the status of discharged pollution load and rainfall conditions. We also investigated rainfall effects on discharged pollution load by analyzing change of the load in accordance with increase of rainfall. The change ratio of discharged pollution load was 18.6% while inflow load only 5.8% for 5 years from 2004 to 2008 in Daejeon district. The greatest rainfall and rain days were over 2 times than the least during the period. This change in rainfall could have great effect on discharged pollution load. The analysis showed that discharged pollution load increased 2.1 times in case rainfall increased 2 times and 1.2 times in case rain days increased 2 times. Rainfall effects, therefore, should be considered to make resonable evaluation of discharged pollution load in the assessment of annual performances.

압력과 모멘트의 복합하중을 받는 곡관의 소성 붕괴하중 예측식 개발 (Closed-Form Plastic Collapse Loads of Pipe Bends Under Combined Pressure and In-Plane Bending)

  • 오창식;김윤재
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.1008-1015
    • /
    • 2006
  • Based on three-dimensional (3-D) FE limit analyses, this paper provides plastic limit, collapse and instability load solutions for pipe bends under combined pressure and in-plane bending. The plastic limit loads are determined from FE limit analyses based on elastic-perfectly plastic materials using the small geometry change option, and the FE limit analyses using the large geometry change option provide plastic collapse loads (using the twice-elastic-slope method) and instability loads. For the bending mode, both closing bending and opening bending are considered, and a wide range of parameters related to the bend geometry is considered. Based on the FE results, closed-form approximations of plastic limit and collapse load solutions for pipe bends under combined pressure and bending are proposed.

제주계통의 기온변화 민감도를 반영한 주말 전력수요예측 (A Study on the Weekend Load Forecasting of Jeju System by using Temperature Changes Sensitivity)

  • 정희원;구본희;차준민
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.718-723
    • /
    • 2016
  • The temperature changes are very important in improving the accuracy of the load forecasting during the summer. It is because the cooling load in summer contribute to the increasing of the load. This paper proposes a weekend load forecasting algorithm using the temperature change characteristic in a summer of Jeju. The days before and after weekends in Jeju, when the load curves are quite different from those of normal weekdays. The temperature change characteristic are obtained by using weekends peak load and high temperature data. And load forecasted based on the sensitivity between unit temperature changes and load variations. Load forecast data with better accuracy are obtained by using the proposed temperature changes than by using the ordinary daily peak load forecasting. The method can be used to reduce the error rate of load forecast.

저속 장행정 박용디젤기관의 속도제어에 관한 연구 (A STUDY ON THE SPEED CONTROL OF A LOW SPEED-LONG STROKE MARINE DIESEL ENGINE)

  • 유영호;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.53-61
    • /
    • 1988
  • Speed of a diesel engine is usually controlled by the hydraulic governor which uses the centrifugal force of rotating fly balls for sensing the error speed. But for a recently developed high efficient, low speed and long stroke 2 cycle marine diesel engine, this governor doesn't work well enough because of too much changes of toraring force during one revolution of engine and too long uncontrollable time due to small numbers of cylinder. For improvement of jiggling phenomena and unstability various studies are being carried out, but they are not enough for a steep load change in a small ship's generator plant or at rough sea condition in a propulsion engine. In this paper, authors propose a new method to control a fuel before the change of angular velocity due to load change by feedforward the change of load, and find that the proposed method shows quite a good control performance in comparision to the customary PID control method by simulation using a digital computer for the various load change.

  • PDF

응력확대계수측정을 위한 하중에 의한 자속밀도변화의 실험적 연구 (Experimental Research of Change in Magnetic Flux Density Due to Load for Measuring KI)

  • 이정희
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.129-132
    • /
    • 2004
  • In order to determine the effective way of measuring the Mode I stress intensity factor, $K_I$, by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux density above the cracked specimen surface was studied experimentally. The change in magnetic flux in the air above the cracked specimen made of aluminum alloy is measured by changing the load by four-point bending. The magnetic flux in the air is almost not changed by increasing the load in teh specimen. The change in potential drop due to load is not caused by the change in electro-motive force induced in the coiled measuring system. This experimental result agree to the result of theoretical analysis in reference 7).

  • PDF