• Title/Summary/Keyword: chan-su

Search Result 2,749, Processing Time 0.028 seconds

A Study on the Analysis of Five Artificial Sweetners in Beverages by HPLC/MS/MS (HPLC/MS/MS를 이용한 음료류 중 인공감미료 동시분석에 관한 연구)

  • Lee, Seong-Bong;Yong, Kum-Chan;Hwang, Sun-Il;Kim, Young-Su;Jung, You-Jung;Seo, Mi-Young;Lee, Chang-Hee;Sung, Jin-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.327-333
    • /
    • 2014
  • A method for analysis of five artificial sweetners (sodium saccharin, aspartame, acesulfame-K, sucralose, cyclamate) in beverage samples was developed using high-performance liquid chromatography/triple quadrupole mass spectrometry (HPLC/MS/MS). The method uses a single-step dilution for sample preperation. Seperation was achieved on a $C_{18}$ column ($2.1{\times}150mm$, $3.5{\mu}m$) with A- 2% methanol (1 mM ammonium acetate), B-95% methanol (1 mM ammonium acetate) as mobile phase with gradient mode. The quantitation of target compounds was performed by external calibration in selected reaction monitorning (SRM) mode. The coefficient of determination of calibration curve for sodium saccharin, aspartame, acesulfame-K, sucralose and cyclamate were 0.9957, 0.9991, 0.9943, 0.9982 and 0.9948, respectively. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 0.001~0.022 mg/L and 0.004~0.073 mg/L, repectively. Recoveries for beverage samples were in the range of 92.76~113.50% with RSD < 10.91%. The method has applied to the determination of the five sweetners in 102 beverage samples. Three artificial sweetners-aspartame, acesulfame-K, sucralose were detected from 42 samples. Sodium saccharin and cyclamate were not detected in all samples.

INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR (설측 복합레진 색상이 치아 순측 색상에 미치는 영향)

  • Mun, Seung-Hui;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.309-323
    • /
    • 2009
  • In this study we evaluated the influence of both the thickness of residual enamel and the color of the composite resins applied to lingual surface on the labial surface color. Background plates were made by randomly (A1, A2, A6D, B1, B2, B3, C1, C2, C6D) selected colors of Filtek Supreme (3M ESPE, St. Paul, U.S.A.) composite resin. Crown portion of 9 maxillary central incisors were cut off and embedded with acrylic resin except labial surface. Samples of average thickness of 2.2 mm were obtained after cutting it in a thickness of 2.5 mm from the labial surface and sandpaper polish. The shade of composite resin background was measured using Spectrophotometer ($Spectrolino^{(R)}$, GretagMacbeth, Regensdorf, Switzerland). And CIE $L^{\ast}a^{\ast}b^{\ast}$value of 2.2 mm thickness tooth samples were measured on the 9 composite resin backgrounds. And then, the cutting side of tooth samples was ground to the extent of 1.9 mm, 1.6 mm, 1.3 mm, 1.0 mm and placed on composite resin backgrounds and measured $L^{\ast}a^{\ast}b^{\ast}$values with the same method. In all samples, $L^{\ast}$value and $b^{\ast}$value seemed to have a tendency of decreasing as thickness of tooth sample becomes thinner regardless of background colors (p < 0.05). But, $a^{\ast}$value didn't show the significant differences depending on the thickness.

The evaluation of color and color difference according to the layering placement of Incisal shade composites on the body composites of the indirect resin restoration (간접 수복용 복합레진의 Incisal 색상 적층 두께에 따른 표면 색상 및 색차의 평가)

  • Park, Su-Jung;Lee, Han-Young;Nah, Myong-Yun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the surface color of indirect resin restoration according to the layering placement of different shade of incisal composite. Materials and Methods: In this study, CIE $L^*a^*b^*$ value of 16 Body composite of Tescera ATL (Bisco, Schaumburg IL,USA) was measured by spectrophotometer (NF999, Nippon Denshuku, Japan), and compared to CIE $L^*a^*b^*$ value of Vitapan shade guide. Nine shade Incisal composite of Tescera ATL were buildup to 1 mm thickness on Body composites inlay block, and CIE $L^*a^*b^*$ value was measured. Incisal composite was ground to 0.5 mm thickness and CIE $L^*a^*b^*$ value was re-measured. Color difference between Body composite and Incisal composites layered on Body composite was calculated as a function of thickness. Results: Color difference between corresponding shade of Tescera Body composite and Vitapan shade guide was from 6.88 to 12.80. $L^*$ and $b^*$ value was decreased as layering thickness of Incisal composite on Body composite was increased. But, $a^*$ value did not show specific change tendency. Conclusions: Surface color difference between Body composites and Incisal composites layered on Body composite was increased as the layering thickness of Incisal composite increased (p < 0.05).

PROPOSAL OF NEW DENIAL COLOR-SPACE FOR AESTHETIC DENIAL MATERIALS (치과용 심미 수복 재료들의 색상 연구를 통한 새로운 치과용 색체계의 제안)

  • Oh, Yun-Jeong;Park, Su-Jung;Kim, Dong-Jun;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.

Effect of Antler Velvet Ethanol Extract on Common Serum Chemistry Panels and Histopathological Change in Rats Exposed to 2,3,7,8-Tetrachlorodibenzo-p-dioxin (녹용 에탄올 추출물이 2,3,7,8 Tetrachlorodibenzo-p-dioxin에 노출된 랫드의 일반 혈액 화학 지수 및 조직 병변에 미치는 효과)

  • Choi, Kyung-Yun;Hwang, Seock-Yeon;Lee, Su-Chan;Kim, Si-Kwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.9
    • /
    • pp.1178-1184
    • /
    • 2006
  • This study was carried out to investigate the effect of ethanol extract of antler velvet (EAV) on common serum chemistry panels and histopathological change in rats exposed to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Administration of TCDD ($50{\mu}g/kg$ body weight) induced significant decrease in platelet count (p<0.01), creatine phosphokinase (CPK, p<0.01), lactatate dehydrogenase (LDH, p<0.05) and glucose (p<0.05) levels and increase in hemoglobin (p<0.05), aspartate aminotransferase (AST, p<0.01), alanine amino transferase (ALT, p<0.05) and lipase activities (p<0.05), and blood urea nitrogen (BUN, p<0.05), triglyceride (p<0.01) and low density lipoptotein cholesterol (LDL-C, p<0.05) levels. However, pretreatment of EAV at daily dose of 20 mg/kg b.w. from 1 wk before TCDD exposure for 5 wks attenuated the abnormality of the overall serum chemistry panels but statistical difference between TE and TA groups was observed only in testicular weight (p<0.01), LDH activity (p<0.05), glucose (p<0.05) and lipase activity (p<0.01). In addition, TCDD induced significant histopathological changes including swelling, fatty metamorphosis, and vacuolar degeneration in liver; edema in proximal and distal convoluted tubules, and glomerulus in kidney; severe atrophy of red purple and appearance of significant number of macrophage in spleen; prominent atrophy and decrease in immune cells in thymus. On the other hand, administration of EAV attenuated histopathological damage induced by TCDD. These results further suggest that administration of EAV attenuates TCDD induced testicular, liver, pancreatic, hematopoietic and nephrotic toxicities in rats.

An Elementary School Children Screen Test for Attention Deficit Hyperactivity Disorder in Taegu City (대구지역 국민학교 어린이의 주의력 결핍 과잉 운동 장애 경향에 대한 선별 검사)

  • Park, Hyung-Bae;Kim, Jin-Sung;Jang, Sang-Ruyl;Park, Sung-Chan;Suh, Hye-Sao;Lee, Kwang-Hun;Kim, Young-Uck;Kim, Chang-Su
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.1
    • /
    • pp.56-74
    • /
    • 1995
  • The authors applied ADDES-HV parent evaluation scale for the purpose of screening test to 538 2nd grade elementary school students from March 1994 to May. The results were as follows: There was no differences in scores of ADHD between schools. In comparing the male and female between three school students, male students showed signifieant high scores (p<0.05) than female students in the score of ADDES-HV subscale and total. There was no significant differences in ADDES-HV scale between male students and female students in both ADHD patients and normal controls. In reliability test for test and retest, the reliability coefficient was higher satisfatorily and that of inattention was 0.80, inpulsivity was 0.69, hyperactivity was 0.63 and the total score was 0.82. In reliability test by internal consistancy, the Cronbach ${\alpha}$ coefficient of patient group was 0.85(p<0.05) and that of normal control was 0.84(p<0.05). The Concurrent validity between ADDES-HV scale and DSM-III-R scale was 0.57(p<0.05) in ADHD patient group and 0.84(p<0.05) in normal control group. In discriminant validity test between ADHD patient group and normal control, the ADHD patient group showed higher score(p<0.05). The total disciminant capacity of the patient group in ADDES-HV scale was 94.44%. When we regard the cut off point as standard deviation 1.5, the male student was 80 score and the female student was 69 score. In this point of view, ADDES-HV scale was proved to be the useful screening test tool for ADHD research and showed higher reliability and validity in applying to Korean subjects.

  • PDF

Prelaunch Study of Validation for the Geostationary Ocean Color Imager (GOCI) (정지궤도 해색탑재체(GOCI) 자료 검정을 위한 사전연구)

  • Ryu, Joo-Hyung;Moon, Jeong-Eon;Son, Young-Baek;Cho, Seong-Ick;Min, Jee-Eun;Yang, Chan-Su;Ahn, Yu-Hwan;Shim, Jae-Seol
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.251-262
    • /
    • 2010
  • In order to provide quantitative control of the standard products of Geostationary Ocean Color Imager (GOCI), on-board radiometric correction, atmospheric correction, and bio-optical algorithm are obtained continuously by comprehensive and consistent calibration and validation procedures. The calibration/validation for radiometric, atmospheric, and bio-optical data of GOCI uses temperature, salinity, ocean optics, fluorescence, and turbidity data sets from buoy and platform systems, and periodic oceanic environmental data. For calibration and validation of GOCI, we compared radiometric data between in-situ measurement and HyperSAS data installed in the Ieodo ocean research station, and between HyperSAS and SeaWiFS radiance. HyperSAS data were slightly different in in-situ radiance and irradiance, but they did not have spectral shift in absorption bands. Although all radiance bands measured between HyperSAS and SeaWiFS had an average 25% error, the 11% absolute error was relatively lower when atmospheric correction bands were omitted. This error is related to the SeaWiFS standard atmospheric correction process. We have to consider and improve this error rate for calibration and validation of GOCI. A reference target site around Dokdo Island was used for studying calibration and validation of GOCI. In-situ ocean- and bio-optical data were collected during August and October, 2009. Reflectance spectra around Dokdo Island showed optical characteristic of Case-1 Water. Absorption spectra of chlorophyll, suspended matter, and dissolved organic matter also showed their spectral characteristics. MODIS Aqua-derived chlorophyll-a concentration was well correlated with in-situ fluorometer value, which installed in Dokdo buoy. As we strive to solv the problems of radiometric, atmospheric, and bio-optical correction, it is important to be able to progress and improve the future quality of calibration and validation of GOCI.

Seasonal and Inter-annual Variations of Sea Ice Distribution in the Arctic Using AMSR-E Data: July 2002 to May 2009 (AMSR-E 위성 데이터를 이용한 북극해빙분포의 계절 변동 및 연 변동 조사: 2002년 7월 ~ 2009년 5월)

  • Yang, Chan-Su;Na, Jae-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.5
    • /
    • pp.423-434
    • /
    • 2009
  • The Arctic environment is sensitive to change of sea-ice distribution. The increase and decrease of sea ice work to an index of globe warming progress. In order to predict the progress of hereafter earth global warming, continuous monitoring regarding a change of the sea ice area in the Arctic should be performed. The remote sensing based on an artificial satellite is most effective on the North Pole. The sea ice observation using a passive microwave sensor has been continued from 1970's. The determination of sea ice extent and ice type is one of the great successes of the passive microwave imagers. In this paper, to investigate the seasonal and inter-annual variation of sea-ice distribution we used here the sea ice data from July 2002 to May 2009 around the Arctic within $60^{\circ}N$ for the AMSR-E 12.5km sea-ice concentration, a passive microwave sensor. From an early analysis of these data, the arctic sea-ice extent has been steadily decreasing at a rate of about 3.1%, accounting for about $2{\times}10^5\;km^2$, which was calculated for the sea-ice cover reaching its minimum extent at the end of each summer. It is also revealed that this trend corresponds to a decline in the multi-year ice that is affected mainly by summer sea surface and air temperature increases. The extent of younger and thinner (first-year) ice decreased to the 2007 minimum, but rapidly recovered in 2008 and 2009 due to the dramatic loss in 2007. Seasonal variations of the sea-ice extent show significant year-to-year variation in the seasons of January-March in the Barents and Labrador seas and August-October in the region from the East Siberian and Chukchi seas to the North Pole. The spatial distribution of multi-year ice (7-year old) indicates that the perennial ice fraction has rapidly shrunk recently out of the East Siberian, Laptev, and Kara seas to the high region of the Arctic within the last seven years and the Northeast Passage could become open year-round in near future.

Effect of 10 Weeks Smart Machine Circulation Exercise on Body Composition, Lung Function, Blood Lipids and Insulin Resistance in Obesity Middle-aged Women (10주간 스마트머신 순환운동이 비만 중년여성의 체조성, 폐기능, 혈중지질 및 인슐린 저항성에 미치는 영향)

  • Kim, Min-Chan;Ha, Soo-Min;Koh, Su-Han;Kim, Jong-Won;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.951-962
    • /
    • 2021
  • The purpose of this study was to analyze the effects of smart machine circulation exercise on body composition, lung function, blood lipid and insulin resistance in obesity middle-aged women among 40-60 years by dividing them into a smart machine circulation exercise group(n=8), and control group(n=6). The smart machine circulation exercise program included 55-minutes sessions thrice each week at the following intensities: The strength of aerobic exercise is applied to smart machines by linking the smart machine with the POLAR T31; the 1-4 week is 40-50%HRR, 5-8 week is 50-60%HRR, and 9-10 week is 60-70%HRR. The strength of the resistance exercise was tested using a smart machine based on the constant velocity motion, and then, using the 1-RM data value, applied 40% 1-RM for 1-4 weeks, 60% 1-RM for 5-8 weeks, and 80% 1-RM for 9-10 week. As a results, body composition indicated that weight, BMI, %BF, WHR had a significant interaction effect. Lung function indicated that FVC levels significantly changes in the exercise group and the between groups difference in changes at 10week was significant. Also, FVC and FEV1 significantly showed interaction effect. TC, TG and HDL-C levels significantly changes in smart machine circulation exercise group and the between-group difference in changes after 10 weeks was significant. TC, TG and HDL-C significantly showed interaction effect. Insulin resistance demonstrated that Insulin, Glucose and HOMA-IR levels significantly showed difference over 10 weeks between group. Therefore, the 10 weeks smart machine circulation exercise positively effects on the body composition, lung function, blood lipids, and insulin resistance in obesity middle-aged women and this smart machine circulation exercise can improve their obesity and prevent obesity.

Efficacy of Listeria Innocua Reduction on Enoki Mushrooms by Utilization of an Air Sterilization Device (공기 살균 장치 적용 팽이버섯 재배사의 Listeria Innocua 저감 효과)

  • Lee, Hyun-Dong;Yu, Byeong-Kee;Seo, Da-Som;Kim, Se-Ri;Lee, Chan-Jung;Kwak, Kang-Su
    • Journal of Mushroom
    • /
    • v.19 no.3
    • /
    • pp.210-215
    • /
    • 2021
  • For sterilization of microorganisms of the Listeria genus contaminating enoki mushroom, pilot mushroom grower equipped with air sterilization devices were developed. Sterilization experiments were performed using physical and chemical treatments. Internal temperature and humidity were controlled, maintaining 6.62℃±0.30 in the upper shelves, 6.46℃±0.24 in the middle shelves, and 6.48℃±0.25 in the lower shelves. Humidities were 79.97%±4.42, 79.43%±4.06, and 79.94±4.30%, respectively, with a temperature setting of 6.5℃, and a relative humidity of 75%. A suitable enoki mushroom cultivation stage for air sterilizer application was during the growth stage, with temperature in the 6.5~8.5℃ range, and humidity of 70~80%. At these same internal conditions, the ozone concentration in the mushroom cultivator was found to be 160 ppb during ion-cluster generator operation. After physical sterilization, the Listeria innocua survival rate was 0.1 to 0.9% using ion cluster sterilization, and 9.3 to 10.6% using UV air sterilization. The Listeria innocua survival rates on different materials were 9.3~10.6% on the metal specimen, and 9.9~16.2% on the plastic wrapper. The survival rate was particularly high on the rough side of the plastic wrapper. Ion cluster air sterilization is a labor-saving and effective method for suppressing the occurrence of Listeria bacteria on mushroom growers walls and shelves. For the plastic wrapper, chemical sterilization is more effective than physical sterilization.