• Title/Summary/Keyword: chamber test

Search Result 1,528, Processing Time 0.029 seconds

Selective Mechanism of Oxvfluorfen and Chlormethoxynil in Crops and Weed Species (Oxyfluorfen과 Chlormethoxynil의 선택작용성(選擇作用性))

  • Lee, J.H.;Pyon, J.Y.;Lee, J.Y.
    • Korean Journal of Weed Science
    • /
    • v.14 no.4
    • /
    • pp.280-290
    • /
    • 1994
  • The germination and the nutrient culture tests in the growth chamber and pot experiment under two types of soil conditions were conducted to determine the selectivity of oxyfluorfen and chlormethoxynil in crops and weeds and for characterization of selective mode of action, the absorption study was also conducted with different absorption methods and application time using $^{14}C$-oxyfluorfen. Oxyfluorfen showed more growth inhibitory effects than chlormethoxynil. In the nutrient culture test, rice growth was greatly inhibited at 2-leaf stage than at 4-leaf stage, and the shoot parts were more inhibited than the root parts. By preemergence application of both herbicides, higher growth inhibition was observed in sandy loam soil than in clay loam soil. Absorption and translocation of $^{14}C$-oxyfluorfen were higher by foliar application than by root treatment, and selectivity of crops and weed species may be explained partly by the amount of absorption.

  • PDF

A Comparison of Stainless-Steel File and MFile-System® Ni-Ti Rotary Instrument in Canal Preparation using Dental Computed Tomography (치과용 단층촬영을 이용한 Stainless-Steel File과 MFile-System® 전동식 기구의 근관 성형 능력에 대한 비교 연구)

  • Seo, Dong-Jin;Yoon, Mi-Ran;Lee, Rin;Yu, Mi-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • Objectives The aim of this study is to compare the quality of root canal preparation completed using MFile-$System^{(R)}$ instrument ( Komet, Gebr.Brsaseler, Germany) and conventional stainless steel file in the canals of Maxillary molar teeth that had a canal curvature between $25^{\circ}$ or more Materials & Methods Buccal canals of 24 first and second maxillary molar teeth, extracted for periodontal and prosthetic reasons were used. Tissue fragments and calcified debris were removed from teeth by scaling and the teeth were stored in 10% formalin solution for 24 hour. Then, teeth were stored in saline until used. To be included the roots had to have completed formed apices and angle of curvature ranging between $25^{\circ}$ or more according to the criteria described by Schneider(1971). Palatal and Second mesiobuccal canals were not included. Teeth were embedded into transparent acrylic. The teeth were randomly divided into two experimental groups. All teeth were scanned by Dental CT (PSR9000N, Asahi, Japan) to determine the root canal shape before instrumentation. Image slices were prepared from the apical end point to the pulp chamber. The first two sections were 2 mm from the apical end of root and 2 mm below the orifice. Further section was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. 12 teeth were instrumented using stainless steel fileand another 12 teeth were instrumented using MFile-$System^{(R)}$. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross sectional images taken prior to canal preparation. Amount of transportation and centering ability was assessed. Student's t-test was used for statistical analysis. Result Less transportation occurred with MFile-$System^{(R)}$ rotary instrumentation than stainless steel instrument. MFile-$System^{(R)}$ had better centering ability than stainless steel instrument. Conclusion MFile-$System^{(R)}$ rotary instrumentation transported canals less and had good centering ability.

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

TEM 도파관을 이용한 전자파 장해 측정 연구 및 표준화 동향

  • 권종화
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.51-62
    • /
    • 2002
  • EMI/EMS 측정을 위해서는 주변 전자파 잡음(background noise)이 낮은 야외시험장(Open Area Test Site)이 가장 바람직하나, 근래 전자(전기 기기 사용의 증가와 방송.무선통신 시스템의 다양화로 인한 인공잡음(artificial noise)의 증대로 조건에 부합된 부지 선정이 어렵고, 설치 비용이 매우 크며 날씨 변화에 따라 시험 계획이 변경 될 수도 있는 단점이 있다. 전자파 분-무반사실(Semi Anechoic Chamber)은 대부분의 환경 잡음을 감쇠시키므로 야외시험장처럼 장소의 구애를 받지 않아 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하다. 그러나 큰 설치 공간과 많은 시설 유지 비용을 필요로 하며, 저주파 대역에서는 반사에 의한 공진을 완전히 제거할 수 없어 성능이 떨어진다. 또한, 최근 컴퓨터 CPU의 동작주파수가 급속하게 높아지고 PCS, IMT-2000 등과 같은 이동전화의 사용주파수도 계속해서 높아짐에 다라 미연방통신위원회(Federal Communication Commission)에서는 5㎓까지의 복사 방출 시험을 요구하고 있다. IEC 61000-4-3 복사 내성 시험규격도 휴대폰 주파수인 2㎓까지 확장되었으며 IMT-2000, Bluetooth 등 새로운 이동통신서비스가 속속 개발됨에 따라 18㎓ 까지 시험 주파수가 확장되는 추세이다. 그러나, 현재 국내 각 연구실에서 보유하고 있는 야외시험장이나 전자파 반-무반사실의 경우 1㎓이상에서의 시험이 곤란하여 수 ㎓주파수대역에서 시험이 가능한 복사 및 내성시험 시설이 필요하게 되었다. 이러한 문제점들을 해결하기 위해 고안된 대용 측정 시설 중 대표적인 것이 TEM 셀이나 GTEM셀과 같은 TEM 도파관(waveguide) 형태의 장비들이다. 이들은 본래 EMS 측정을 위한 장비이지만 협소한 공간이나 외부와의 전자파 간섭의 우려가 없고, 설치가 비교적 자유로워 여러 연구기관에서 도파관 원리를 이용한 측정 방식을 연구(개발하여 범용적인 전자파 적합성 측정 장비로서 활용하고 있다. 야외시험장과 무반사실 등이 안테나에 의한 피시험기기 주변 공간에서의 1점 측정으로 인해 시험 시간이 많아 소요되는 공통적인 단점이 있는 반면, TEM 도파관에 의한 측정은 일단 피시험기기의 모델링 정보만 얻어지면 계산에 의해 EMI 측정을 바로 할 수 있다. <표 1>에서 현재 상용화되어 사용되고 있는 TEM/GTEM 셀, 야외 시험장 및 전자파 무반사실에 대해 EMI 측정과 관련된 몇 가지 사안에 대해 비교하였다. 본 문서에서는 야외시험장이나 전자파 반-무반사실 등과 같은 기존 EMI/EMS 측정 시설의 단점을 보완하고, 광대역 특성을 갖는 대용 측정 시설로서의 TEM 도파관에 대해 소개하고 야외시험장 결과와의 상관관계 알고리즘 및 표준화 동향에 대해 기술하였다. 2절에서는 대표적인 TEM 도파관 구조의 측정 시설인 TEM 셀과 GTEM 셀의 전기적.구조적 특징에 대해 간단히 기술하고, 3절에서는 TEM 셀과 GTEM 셀에서이 측정결과를 이용하여 야외 시험장 결과를 얻어내는 상관관계 알고리즘에 대해 기술하였다. 4절에서는 IEC/CISPR와 TC77에서의 표준화 활동을 중심으로 현재 진행중인 TEM 도파관 관련 표준화 동향과 내용에 대해 기술하고자 한다.

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

Effect of graphene oxide on mechanical characteristics of polyurethane foam (산화그래핀이 폴리우레탄 폼 기계적 강도에 미치는 영향)

  • Kim, Jong-Min;Kim, Jeong-Hyeon;Choe, Young-Rak;Park, Sung Kyun;Park, Kang Hyun;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.493-498
    • /
    • 2016
  • In the present study, graphene oxide based polyurethane foams were manufactured as a part of the development process of mechanically strengthened polyurethane foam insulation material. This material is used in a liquefied natural gas carrier cargo containment system. The temperature of the containment system is $-163^{\circ}C$. First, graphene oxide was synthesized using the Hummers' method, and it was supplemented into polyol-isocyanate reagent by considering a different amount of graphene oxide weight percent. Then, a bulk form of graphene-oxide-polyurethane foam was manufactured. In order to investigate the cell stability of the graphene-oxide-polyurethane foam, its microstructural morphology was observed, and the effect of graphene oxide on microstructure of the polyurethane foam was investigated. In addition, the compressive strength of graphene-oxide-polyurethane foam was measured at ambient and cryogenic temperatures. The cryogenic tests were conducted in a cryogenic chamber equipped with universal testing machine to investigate mechanical and failure characteristics of the graphene-oxide-polyurethane foam. The results revealed that the additions of graphene oxide enhanced the mechanical characteristics of polyurethane foam. However, cell stability and mechanical strength of graphene-oxide-polyurethane foam decreased as the weight percent of graphene oxide was increased.

The Frequency of Detecting Prevotella intermedia and Prevotella nigrescens in Korean Adult Periodontitis Patients (한국인 치주 감염 환자에서의 Prevotella intermedia와 Prevotella nigrescens의 발현빈도)

  • Peck, Seung-Yup;Ku, Young;Rhyu, In-Cheol;Hahm, Byung-Do;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.419-429
    • /
    • 2000
  • Prevotella intermedia has been implicated as a potent pathogen in many kinds of periodontal, pulpal and periapical diseases. However, it has been isolated from periodontally healthy adults and from edentulous children as well. The intraspecies heterogeneity of Prevotella intermedia has been demonstrated in early studies and finally Shah & Gharbia confirmed the existence of 2 DNA homology groups and proposed dividing Prevotella intermedia into 2 species, Prevotella intermedia and Prevotella nigrescens. This study was designed to examine the frequency of Prevotella intermedia and Prevotella nigrescens in diseased periodontal pockets and healthy gingival sulcus of Korean people by PCR based on 16s ribosomal DNA sequence. One hundred adults who had adult periodontitis but not taken any periodontal treatment or antibiotics during previous 6 months and 50 adults who had healthy periodontal tissue were selected for this study. The sulcular fluid was collected into VMGA by sterilized paper point and diluted to 1,000 times in anaerobic chamber. $100{\mu}{\ell}$ of sample was cultured in $37^{\circ}C$ for 10 days. Among the bacterial colonies, BPB were selected and cultured in BHI broth and then Prevotella intermedia was identified through Gram staining and biochemical test. Identified Prevotella intermedia was cultured again and centrifuged. DNA was extracted from the pellet using several reagents. PCR was performed by previously designed primer. The results were followed. 1. BPB were isolated from 39 of 100 samples of diseased periodontal pockets(39%). 2. Prevotella intermedia was identified from 24 of 39 BPB samples. 3. Among 24 Prevotella intermedia, 21 were confirmed as Prevotella inter - media(87.5) and 2 were confirmed as Prevotella nigrescens(8.33%). 4. BPB were isolated from 9 of 50 samples of periodontally healthy patients. Among them only two were identified as Prevotella intermedia, that is, one was confirmed as Prevotella intermedia and the other was Prevotella nigrescens.

  • PDF

Development of On-line Quality Sorting System for Dried Oak Mushroom - 3rd Prototype-

  • 김철수;김기동;조기현;이정택;김진현
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • In Korea, quality evaluation of dried oak mushrooms are done first by classifying them into more than 10 different categories based on the state of opening of the cap, surface pattern, and colors. And mushrooms of each category are further classified into 3 or 4 groups based on its shape and size, resulting into total 30 to 40 different grades. Quality evaluation and sorting based on the external visual features are usually done manually. Since visual features of mushroom affecting quality grades are distributed over the entire surface of the mushroom, both front (cap) and back (stem and gill) surfaces should be inspected thoroughly. In fact, it is almost impossible for human to inspect every mushroom, especially when they are fed continuously via conveyor. In this paper, considering real time on-line system implementation, image processing algorithms utilizing artificial neural network have been developed for the quality grading of a mushroom. The neural network based image processing utilized the raw gray value image of fed mushrooms captured by the camera without any complex image processing such as feature enhancement and extraction to identify the feeding state and to grade the quality of a mushroom. Developed algorithms were implemented to the prototype on-line grading and sorting system. The prototype was developed to simplify the system requirement and the overall mechanism. The system was composed of automatic devices for mushroom feeding and handling, a set of computer vision system with lighting chamber, one chip microprocessor based controller, and pneumatic actuators. The proposed grading scheme was tested using the prototype. Network training for the feeding state recognition and grading was done using static images. 200 samples (20 grade levels and 10 per each grade) were used for training. 300 samples (20 grade levels and 15 per each grade) were used to validate the trained network. By changing orientation of each sample, 600 data sets were made for the test and the trained network showed around 91 % of the grading accuracy. Though image processing itself required approximately less than 0.3 second depending on a mushroom, because of the actuating device and control response, average 0.6 to 0.7 second was required for grading and sorting of a mushroom resulting into the processing capability of 5,000/hr to 6,000/hr.

  • PDF

Screening for Resistance to Downy Mildew among Major Commercial Cucumber Varieties (주요 오이 품종의 노균병에 대한 저항성 검정)

  • Lee, Jung-Sup;Han, Kyung-Sook;Lee, Seong-Chan;Soh, Jae-Woo
    • Research in Plant Disease
    • /
    • v.19 no.3
    • /
    • pp.188-195
    • /
    • 2013
  • This study was carried out for the downy mildew resistant test between 2010 and 2012. A set of 22 accessions belonging to 2 wild species and 20 varieties of the genus Cucumis, originating mainly from the Asian Vegetable Research and Development Center (AVRDC) Gene Centre, was evaluated for resistance to Pseudoperonospora cubensis, causal agent of cucumber downy mildew. The youngest fully expanded true leaves were found suitable for in vitro screening. Both leaf discs and full leaves could be kept fresh longer when applying 0.2 ${\mu}g/ml$ of gibberellin acid (GA). The incubation temperature of $20^{\circ}C$ was found to be the most suitable temperature for symptom development comparing with 15 and $25^{\circ}C$. Symptom development was faster when contact diseased leaf discs (2 weeks after inoculation) on to fresh leaf samples comparing with using conidia suspension ($10^5$ spores/ml). The numbers of spots in 'C-19' were lower than other varieties. 'C-19' variety was also showed the highest level of downy mildew resistant at $20^{\circ}C$ chamber in 6 days after inoculating with pathogen and displayed 0.90 (under 10%) of the infected rate. However, other varieties displayed susceptible in the pathogen sprayed plots. 'C-19' was the most resistant variety and no lesion was observed. Based on all data, 'C-19' can be a useful variety for the prevention of downy mildew.

Occurrence of Target Spot on Rosemary Caused by Corynespora cassiicola in Korea (Corynespora cassiicola에 의한 로즈마리 점무늬병)

  • Lee, Wang-Hyu;Han, Sang-Jun;Choi, In-Young
    • Research in Plant Disease
    • /
    • v.19 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • The purpose of this experiment was to investigate the development of new spot disease on the leaf and stem of rosemary (Rosmarinus officinalis) in commercial greenhouses at Jeonju and Namwon in Korea. Incidence of target spot on rosemary was higher at the end of the rainy season with high humidity. Those symptoms were black ring spots (3-5 mm in diameter) and withering on green leaves and stems. Conidiophores and conidia were formed on the infected tissue in moist chamber and conidia were shown as the cylindrical and oval types in chain, ranged from 55 to $275{\mu}m$ in length, and 7 to $14{\mu}m$ in width. Conidia with eight to ten pseudosepta were formed on the conidiapore. The optimum growth temperature of isolates was $30^{\circ}C$ on the PDA medium under the dark condition. In the pathogenesis test, the target spot and withering symptoms were appeared on the leaves and stems 3 days after inoculation showing similar symptoms compared to those of in nature. The same fungus was re-isolated from infected lesion, indicating that Corynespora cassiicola caused leaf target spot and twig blight on rosemary. The rDNA ITS nucleotide sequences of the pure cultured isolate from the diseased area on rosemary showed 100% similarity to the sequences of C. cassiicola available in the GenBank database (JQ595296, JQ595297, FJ852715 and AY238606). Therefore, we report that the target spot of leaves and stems in rosemary was caused by C. cassiicola.