• Title/Summary/Keyword: chain stiffness

Search Result 47, Processing Time 0.022 seconds

Propylene/Propane Separation Through Polyimides Containing Bulky Ethyl Substituents (부피가 큰 치환기를 포함하는 폴리이미드의 합성 및 프로필렌/프로판 분리특성)

  • Yoo, Seung Yeon;Park, Ho Bum
    • Membrane Journal
    • /
    • v.30 no.6
    • /
    • pp.450-459
    • /
    • 2020
  • Membrane-based separations have the potential to reduce energy consumption and environmental impact associated with conventional processes. However, many researches have been done to develop new membrane materials with greater selectivity and permeability. Here, we report highly selective membranes by introducing bulky ethyl substituents into the polyimide. The ethyl group in the ortho position to the imide nitrogen interferes the chain packing and increases chain stiffness and the distance between the polymer chains. The polyimide membranes were synthesized from various aromatic dianhydrides and 4,4'-methylenebis(2,6-diethylaniline) (MDEA). The synthesized membranes with increased gas diffusion length due to bulky substituents showed improved propylene/propane (C3H6/C3H8) selectivity. Single gas permeation showed high C3H6/C3H8 selectivity of 14.5, and C3H6 permeability of 7.0 barrer was found in MDEA-polyimide. Mixed-gas permeation results also demonstrate that MDEA-polyimide can achieve high selectivity in mixed-gas environment. Furthermore, this approach could significantly increase the feasibility of economic propylene separation compared to conventional polymer materials.

Dilute Solution Properties of Biopolymer Produced by Alkali-Tolerant Bacillus sp. (알칼리 내성 Bacillus Sp.에 의한 생물 고분자의 희석용액 특성)

  • Lee, Shin-Young;Kim, Jin-Young
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.39-44
    • /
    • 2000
  • Highly viscous biopolymer from alkali-tolerant Bacillus sp. was purified and its solution properties were investigated. The intrinsic viscosities for crude biopolymer and biopolymers purified by dialysis or CPC(cetylpyridinium chloride) treatment were 58.24, 73.60 and 42.18 dL/g, respectively. The intrinsic viscosity of biopolymer showed the maximum value at the neutral pH but it was decreased remarkably at the alkaline or acidic pH. Biopolymer exhibited the property of polyelectrolyte, showing the sharp decrease of intrinsic viscosity by the addition of NaCl. Intrinsic viscosity of dilute solution at the low NaCl concentration was exponentially dependent on temperature and its temperature dependency was increased with NaCl concentrations. The chain stiffness, coil overlap parameter, and critical concentration were 0.09, 5.25 and 0.07g/dL, respectively. Temperature dependency on intrinsic viscosity of biopolymer solution was different each other at $45^{\circ}C$. Flow activation energies at temperatures above $45^{\circ}C$ were constant, while those at temperatures below $45^{\circ}C$ increased with increase of added NaCl concentration.

  • PDF

Accuracy Improvement of a 5-axis Hybrid Machine Tool (5축 혼합형 공작기계의 정밀도 향상 연구)

  • Kim, Han Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.84-92
    • /
    • 2014
  • In this paper, a novel 5-axis hybrid-kinematic machine tool is introduced and the research results on accuracy improvement of the prototype machine tool are presented. The 5-axis hybrid machine tool is made up of a 3-DOF parallel manipulator and a 2-DOF serial one connected in series. The machine tool maintains high ratio of stiffness to mass due to the parallel structure and high orientation capability due to the serial-type wrist. In order to acquire high accuracy, the methodology of measuring the output shafts by additional sensors instead of using encoder outputs at the motor shafts is proposed. In the kinematic view point, the hybrid manipulator reduces to a serial one, if the passive joints in the U-P serial chain at the center of the parallel manipulator are directly measured by additional sensors. Using the method of successive screw displacements, the kinematic error model is derived. Since a ball-bar is less expensive than a full position measurement device and sufficiently accurate for calibration, the kinematic calibration method of using a ball-bar is presented. The effectiveness of the calibration method has been verified through the simulations. Finally, the calibration experiment shows that the position accuracy of the prototype machine tool has been improved from 153 to $86{\mu}m$.

Force-mediated proinvasive matrix remodeling driven by tumor-associated mesenchymal stem-like cells in glioblastoma

  • Lim, Eun-Jung;Suh, Yongjoon;Kim, Seungmo;Kang, Seok-Gu;Lee, Su-Jae
    • BMB Reports
    • /
    • v.51 no.4
    • /
    • pp.182-187
    • /
    • 2018
  • In carcinoma, cancer-associated fibroblasts participate in force-mediated extracellular matrix (ECM) remodeling, consequently leading to invasion of cancer cells. Likewise, the ECM remodeling actively occurs in glioblastoma (GBM) and the consequent microenvironmental stiffness is strongly linked to migration behavior of GBM cells. However, in GBM the stromal cells responsible for force-mediated ECM remodeling remain unidentified. We show that tumor-associated mesenchymal stem-like cells (tMSLCs) provide a proinvasive matrix condition in GBM by force-mediated ECM remodeling. Importantly, CCL2-mediated Janus kinase 1 (JAK1) activation increased phosphorylation of myosin light chain 2 in tMSLCs and led to collagen assembly and actomyosin contractility. Collectively, our findings implicate tMSLCs as stromal cells providing force-mediated proinvasive ECM remodeling in the GBM microenvironment, and reminiscent of fibroblasts in carcinoma.

Aseptic Meningitis after a Lumbar Epidural Steroid Injection -A case report- (요부 경막외 스테로이드 주입 후 발생한 무균성 수막염 -증례 보고-)

  • Hwang, Byeong Mun;Leem, Jung Gil
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.52-55
    • /
    • 2005
  • Complications following a well conducted epidural steroid injection are rare. A 50-year-old man developed a headache and neck stiffness 2 days after a lumbar epidural steroid injection. Under the impression of aseptic meningitis, fluid and nonsteroidal anti-inflammatory drug therapy was started immediately after cerebrospinal fluid (CSF) sampling. The CSF was turbid, and revealed a white blood cell count, protein, glucose and pressure of $550/{\mu}l$ (98% lymphocyte), 107.9 mg/dl, 48 mg/dl (serum 113 mg/dl) and $17cmH_2O$, respectively. The CSF stain and culture, and antibody test and polymerase chain reaction for pathogens were negative. A computed tomography (CT) scan of the brain revealed no abnormality, and a chest roentgenogram and the results of the neurological examination were normal. Under the impression of aseptic meningitis, the condition was managed conservatively, without antibiotics. Seven days later, the clinical symptoms had improved, and the patient discharged.

Studies on CFST column to steel beam joints using endplates and long bolts under central column removal

  • Gao, Shan;Yang, Bo;Guo, Lanhui;Xu, Man;Fu, Feng
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.161-172
    • /
    • 2022
  • In this paper, four specimens of CFST column joints with endplates and long bolts are tested in the scenario of progressive collapse. Flush endplate and extended endplate are both adopted in this study. The experimental results show that increasing the thickness of the endplate could improve the behavior of the joint, but delay the mobilization of catenary action. The thickness of the endplate should not be relatively thick in comparison to the diameter of the bolts, otherwise catenary action would not be mobilized or work effectively. Effective bending deformation of the endplate could help the formation and development of catenary action in the joints. The performance of flexural action in the joint would affect the formation of catenary action in the joint. Extra middle-row bolts set at the endplates and structural components set below the bottom beam flange should be used to enhance the robustness of joints. A special weld access hole between beam and endplate should be adopted to mitigate the chain damage potential of welds. It is suggested that the structural components of joints should be independent of each other to enhance the robustness of joints. Based on the component method, a formula calculating the stiffness coefficient of preloaded long bolts was proposed whose results matched well with the experimental results.

Bulge Characteristics of 1,000 mL Carton Pak according to the Different Storage Conditions (저장유통 조건에 따른 1,000 mL 카톤팩의 벌지현상)

  • 박종대;정관섭
    • Food Science and Preservation
    • /
    • v.10 no.3
    • /
    • pp.293-296
    • /
    • 2003
  • This study was carried out to obtain physical characteristics of paper board and to measure bulge of 1,000 mL carton pak by different storage conditions. Water holding capacity of paper boards were mean of 5.6~7.0%, stiffness of machine direction(MD) was 243.3~266.7 g/cm and cross direction(CD) was 99.2~109.2 g/cm, respectively. The weight of 1,000 mL carton pak were in the range of 29.17~31.26 g. The bulge of carton paks were 6.33~6.93 mm after 7 days at 6$^{\circ}C$ storage, 7.26~8.56 mm after 7 days at 10$^{\circ}C$ and was 8.66 mm after 7 days at 10$^{\circ}C$ treated with 1 hour heat shock per day, respectively. According to this result, the bulge length of 1,000 mL carton pak was showed increased pattern upon increasing the storage temperature and the order was 6$^{\circ}C$ < l0$^{\circ}C$ < 10$^{\circ}C$+ heat shock. To prevent bulge occurence, it was thought to control storage temperature and humidity of paper board or carton pak and to minimize their shock on cold chain system after filling process.

Characterization and Solution Behavior of Polyethylene-based Ionomer Particles in Water (물에서의 폴리에틸렌계 아이오노머 입자 특성과 용액 거동)

  • Yeo, Sang Ihn;Woo, Kyu Whan
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.5
    • /
    • pp.512-518
    • /
    • 1998
  • In this study, various thermodynamic and hydrodynamic parameters characterizing the solution properties of polyethylene ionomer particles in water were determined at $30^{\circ}C$ by means of light scattering and viscosity measurements. Based on the experimental data, we investigated the solution behavior of three kinds of polyethylene ionomers, which are different in composition of the pendant ionic groups of COOK, COOH and $CONH_{2}$, and characterized their particle properties. Ionomers containing 7.6 mol% potassium salt only behave as flexible coils in a relatively good solvent state. On the other hand, two ionomers containing 3.8 mol% amide group together with potassium salt form the compact particles. In addition, the concentration dependence of the effective diffusion coefficient $(D_{eff})$ and the reduced viscosity of the latter ionomers showed the opposite trend from the former, indicating that the composition of the pendant ionic groups have a great influence on the interparticle interaction of ionomers formed in water.

  • PDF

표면 사이즈용 전분이 백상지 품질에 미치는 영향

  • 윤지영;정경태;김대현;이중근;이용규
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.45-45
    • /
    • 2001
  • 종이 표변에 전분 사이징을 하는 목적은 종이가 액체에 대하여 침투저항성을 부여하 여 종이의 인쇄적성을 향상시키며 아울랴 종이의 표면적성과 종이강도 등의 물리적 특 성을 향상시키기 위해서 사용된다. 표면 사이징은 기본적으로 종이 표면에 전분을 이용 한 필름을 형성하여 종이 표면의 공극크기를 줄여 인쇄잉크 등과 같은 액체의 침투속 도를 늦여준다. 현재 국내에서 널리 사용되는 표면 사이징용 전분으로는 산화전분과 자 가변성용 일반전분이 있다. 자가변성용 전분은 효소나 APS로 전분의 chain 길이를 적 당한 점도로 잘라주는 것으로 전분 호액의 노화가 쉽게 일어나는 경향이 있다. 산화전 분은 전분회사에서 산화제를 이용하여 전분의 점도를 사용자의 요구에 따라 조절한 것 으로 water holdout이 개선되고 자가변성용 전분보다는 노화 안정성이 개선되지만 종 이 내부로의 칩투가 많이 일어나 전분 필름 강도가 약해지며 표면 강도 향상 효과가 적고 종이의 광학적 특성을 저하시키는 단점을 지니고 있다. 또한 약 10 ~ 20% 정도 사 용되는 파지의 재활용시 펄프 섬유에 흡착되지 않는 전분으로 인해 백수 내의 COD 및 B BOD를 증가시키는 원인이 된다.따라서 본 연구에서는 펄프 섬유와 친화력이 높아 지료 내첨용 지력증강제로 널리 사용되고 있는 양성 전분의 양이온 치환도 및 점도를 사이즈 프레스에 적합하게 조절 하여 백상지 제조업체의 라언에 적용하였다. 결과분석 항목으로는 파지 재활용에 따른 백수내 COD, 칼숨 이온함량 등의 백수 시스템의 변화와 종이의 물리적, 광학적 특성 및 ink jet 용지의 인쇄적성 등을 측정하여 산화전분과 비교하였다. 그 결과 약 20%의 C COD 감소 효과와 10%정도의 OPR 향상 효과를 얻을 수 있었다. 종이 물성의 경우 인 장강도와 뺏뺏이(stiffness) 및 지분 등을 측정한 결과 산화전분 보다 향상되었다. 특히 지분의 경우, 참여한 회사의 지분관련 complain이 약 80% 정도 감소하는 결과를 나타 내었다. 또한 백상지의 경우 ink jet 프린터에 많이 사용됨으로 ink jet 프린터의 인쇄 적성을 image analyzer로 측정한 결과 산화전분 보다 향상된 결과를 나타내었다.

  • PDF

Analysis on Tension Response of Mooring Line by Lateral Excitation (수평가진에 의한 계류라인의 장력응답 해석)

  • Jung Dong Ho;Kim Hyeon Ju;Moon Deok Su;Park Han Il;Choi Hak Sun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.4
    • /
    • pp.185-191
    • /
    • 2004
  • A mooring system can be applied to keep the position of a floating structures. In this study, the structural analysis is carried out to analyze the dynamic characteristics of a mooring line for a floating breakwater. A three-dimensional equations of motion for a submerged chain are derived. Bending stiffness is considered for the necessary restoring force in the regions of zero tension. A fortran program is to be developed by employing finite difference method. In the algorithm, an implicit time integration and Newton-Raphson iteration are adopted. The results of simulation show good agreement in tension response pattern with the experimental results of a reference. The results of this study can contribute for the design of mooring system for a floating breakwater.

  • PDF