• Title/Summary/Keyword: center point determination.

Search Result 92, Processing Time 0.027 seconds

Determination of EMC and Washoff Characteristics of Stormwater Runoff from Broad-Leaved Forest Areas (산림 활엽수 지역의 강우유출수 유출특성 및 EMC 산정)

  • Kang, Chang Guk;Lee, Soyoung;Gorme, Joan Barniso;Lee, Jea Un;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.393-399
    • /
    • 2009
  • The water of rivers and lakes are affecting by point and nonpoint source pollutions. The point source pollution can be controlled by establishing the treatment plants. However, nonpoint source pollution by various human activities is not easy to be controlled because it is difficult to determine the exits of the water flow and have many exit points. Due to contribution of nonpoint source pollution, the achievement ratio of water quality in rivers and lakes is not high. TMDL is the outstanding water quality control policy because all of the pollutant loadings from the watershed area are counting on the input loads. Our aqua-ecosystem has self-purification process by biological, physical and ecological processes. The self-purification process can remove the pollutant load from background concentrations. Usually forest area is main source of background concentrations. In Korea, about 70% of the national boundary area consists of mountains. This study is conducting as part of long-term monitoring to determine the Event Mean Concentration during a storm. The monitoring was performed on a broad-leaved tree area.

The Optical Characteristics of the Soft X-Ray Telescope Aboard Yohkoh : The On- and Off-Axis Point Spread Function

  • Shin, Junho;Sakurai, Takashi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.64.1-64.1
    • /
    • 2013
  • The point spread function (PSF) of an optical system is in general defined as a two-dimensional intensity distribution which results from a single point source at infinity. It is an important key for the evaluation of the optical performance of an astronomical telescope. The PSFs of the soft X-ray telescope (SXT) aboard Yohkoh were measured in a wide range of the field-of-view under the in-flight configuration at White Sands Missile Range prior to launching the satellite. It has been known that the SXT PSF has a sharp peak at the core and the intensity drops very fast as it goes distant from the center. Due to the combination of this sharp peak at the PSF core and the effect of undersampling by a large pixel size, a carefully designed method is requested in the examination of the PSF data. The pattern of the SXT PSF is determined by the fitting of a mathematical functional form to the pre-launch experimental data. The elliptical Moffat function has been adopted for the evaluation of the SXT PSF. It is revealed from our study that the SXT PSF shows a peculiar characteristics, and thus a careful consideration on the undersampling effect and also a proper choice of statistics are necessary for the determination of the best fit function of the PSF. Details on the on- and off-axis SXT PSF in the field-of-view will be introduced and discussed in our presentation.

  • PDF

Determination of Color Value (L, a, b) in Green Tea Using Near-Infrared Reflectance Spectroscopy (근적외 분광분석법을 이용한 녹차의 색도 분석)

  • Lee, Min-Seuk;Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.108-114
    • /
    • 2008
  • Near infrared spectroscopy (NIRS) is a rapid and accurate analytical method for determining the composition of agricultural products and feeds. The applicability of near infrared reflectance spectroscopic method was tested to determine the color value (L, a, b) of green tea. A total of 162 green tea calibration samples and 82 validation samples were used for NIRS equation development and validation, respectively. In the developed NIRS equation for analysis of the color value (L, a, b), the most accurate equation for L value was obtained at 2, 8, 6, 1 (2nd derivative, 8 nm gap, 6 points smoothing, and 1pointsecond smoothing), and for a, and b value were obtained at 1, 4, 4, 1 (1st derivative, 4 nm gap, 4points smoothing, and 1 point second smoothing) math treatment condition with SNVD (Standard Normal Variate and Detrend) scatter correction method and entire spectrum ($400{\sim}2,500\;nm$) by using MPLS (Modified Partial Least Squares) regression. Validation results of these NIRS equations showed very low bias (L: 0.005%, a: 0.003%, b: -0.013%) and standard error of prediction (SEP, L: 0.361%, a: 0.141%, b: 0.306%) as well as high coefficient of determination ($R^2$, L: 0.905, a: 0.986, b: 0.931). Therefore, these NIRS equations can be applicable and reliable for determination of color value (L, a, b) of green tea, and NIRS method could be used as a mass screening technique for breeding programs and quality control in the green tea industry.

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

Development of an Hazard Analysis Critical Control Point Application Model for a Olive Flounder (Paralichthys olivaceus) Aquaculture Farm (넙치 양식장 위해요소중점관리기준(HACCP) 적용모델 개발)

  • Kim, Tae-Jin;Min, Jin-Gi;Park, Sun-Mee;Choi, Jae-Suk;Lee, Myung Suk;Kim, Young-Mog;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.5
    • /
    • pp.1055-1067
    • /
    • 2013
  • We attempted to apply the HACCP system adopted in the food industry to a olive flounder (Paralichthys olivaceus) aquaculture farm to ensure the hygiene safety of farmed fish. In this study, HACCP system procedures, including HACCP team organization, critical point determination, establishment of standard limits etc., were established using Codex 12 procedures. To determine whether hazards were critical elements, we evaluated the likelihood and seriousness of each hazard element. The likelihood of residual medicine exceeding the acceptable limit in shipped fish products was demonstrated to be a critical hazard element. Management of the shipment stage was determined to be a critical control point (CCP). Checking the records for stock and release and maintaining a history of medicine use before shipping the fish were suggested as monitoring methods. The standards for acceptable residual medicine were set based on relevant laws and regulations, and then the limits were adapted and established for the CCP. An HACCP plan applicable to olive flounder farms was established.

Estimation of Sejong VLBI IVP Point Using Coordinates of Reflective Targets with Their Measurement Errors (반사타겟 좌표 및 오차정보를 이용한 세종 VLBI IVP 위치계산)

  • Hong, Chang-Ki;Bae, Tae-Suk;Yi, Sangoh
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.717-723
    • /
    • 2020
  • Determination of local tie vectors between the space geodetic techniques such as VLBI (Very Long Baseline Interferometer), SLR (Satellite Laser Ranging), DORIS (Doppler Orbit determination and Radiopositioning Integrated on Satellite), GNSS (Global Navigation Satellite System) is essential for combination of ITRF (International Terrestrial Reference Frame). Therefore, it is required to compute IVP (Invariant Point) position of each space geodetic technique with high accuracy. In this study, we have computed Sejong VLBI IVP position by using updated mathematical model for adjustment computation so that the improvement on efficiency and reliability in computation are obtained. The measurements used for this study are the coordinates of reflective targets on the VLBI antenna and their accuracies are set to 1.5 mm for each component. The results show that the position of VLBI IVP together with its standard deviation is successfully estimated when they are compared with those of the results from previous study. However, it is notable that additional terrestrial surveying should be performed so that realistic measurement errors are incorporated in the adjustment computation process.

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Factors Indicating Culture Status During Cultivation of Spirulina (Arthrospira) platensis

  • Kim, Choong-Jae;Jung, Yun-Ho;Oh, Hee-Mock
    • Journal of Microbiology
    • /
    • v.45 no.2
    • /
    • pp.122-127
    • /
    • 2007
  • Factors indicating culture status of two Spirulina platensis strains were monitored in a batch mode cultivation for 36 days. Changing mode in all factors showed a common turning point, indicating shift of cell or culture status. Mean biomass productivity was highly sustained until day 22, chlorophyll a concentration peaked on day 22, pH value was > 12 on day 22, coil number was abruptly shortened on day 22, and floating activity was sustained at greater than 79% after day 22, indicating that day 22 is a criterion reflecting phase-transfer in cell physiology in a batch culture system. Many of these changes may have been caused by increased pH, suggesting that pH control is essential for mass production of S. platensis. Fluctuations in floating activity were likely induced by the number of cellular gas vacuoles. Consequently, coil number per trichome and floating activity of S. platensis could readily act as simple indicators for determination of culture status or harvesting time of cells.

Extraction of Common GCPs from JERS-1 SAR Imagery

  • Sakurai Amamo, Takako;Mitsui, Hiroe;Takagi, Mikio;Kobayashi, Shigeki;Fujii, Naoyuki;Okubo, Shuhei
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.186-191
    • /
    • 1998
  • The first step in change detection in any SAR monitoring, including SAR interferometry, is the co-registration of the images. CCPs (Ground Control Points) for co-registration are usually detected manually, but for qualitative analyses of enormous volumes of data, some automation of the process will become necessary. An automated determination of common CCPs for the same path/row data is especially desirable. We selected the intersections of linear features as the candidates of common GCPs Very bright point targets, which are commonly used as GCPs, have the drawback of appearing and disappearing depending on the conditions of the observation. But in the case of linear features, some detailed elements may appear differently in some case, but the overall line-likeness will remain. In this study, we selected 18 common GCPs for a single-look JERS-1 SAR image of Omaezaki area in central Japan. Although the GCPs in the first image had to be selected either interactively or semi-automatically, the same GCPs in all other images were successively detected automatically using a tiny sub-image around each GCP and a dilated mask of each linear feature in the first image as the reference data.

  • PDF

Determination of Trace Uranium in Human Hair by Nuclear Track Detection Technique

  • Chung, Yong-Sam;Moon, Jong-Hwa;Zinaida En;Cho, Seung-Yeon;Kang, Sang-Hoon;Lee, Jae-Ki
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.225-230
    • /
    • 2001
  • The aim of this study is to describe a usefulness of nuclear analytical technique in assessing and comparing the concentration levels through the analysis of uranium using human hair sample in the field of environment. A fission track detection technique was applied to determine the uranium concentration in human hair. Hair samples were collected from two groups of people - a) workers not dealing with uranium directly, and b) workers possibly contaminated with uranium. The concentration of $^{235}$ U for the first group varied from <1 to 39 ng/g and the second group can be estimated up to the level of $\mu$g/g. Radiographs of heavy-duty work samples contained high dense “hot spots” along a single hair. After washing in acetone and distilled water, external contamination was not totally removed. Insoluble uranium compounds were not completely washed out. The (n, f)- radiography technique, having high sensitivity, and capable of getting information on uranium content at each point of a single hair, is an excellent tool for environmental monitoring.

  • PDF