• Title/Summary/Keyword: cement

Search Result 10,443, Processing Time 0.043 seconds

Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study (내측연결형 임플란트에 체결한 지대주의 수직침하에 대하여 반복하중이 미치는 영향)

  • Seol, Hyon-Woo;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • Purpose: To evaluate the axial displacement of implant-abutment assembly after cyclic loading in internal tapered connection system. Materials and methods: External butt-joint connection implant and internal tapered connection implant were connected with three types of abutment for cement-retained prostheses, i.e. external type abutment (Ext group), internal tapered 1-piece abutment (Int-1 group), and internal tapered 2-piece abutment (Int-2 group). For each group, 7 implants and abutments were used. The implantabutments assemblies were clamped into the implant holder for vertical loads. A dynamic cyclic loading was applied for $150{\pm}10N$ at a frequency of 4 Hz. The amount of axial displacement of the abutment into the implant was calculated at each cycle of 0, 5, 10, 50, 100, 1,000, 5,000, and 10,000. A repeated measures analysis of variance (ANOVA) for the overall effect of cyclic loading and the pattern analysis by linear mixed model were used for statistical analysis. Differences at P<.05 were considered statistically significant. Results: The mean axial displacement after 10,000 cycles were $0.714{\pm}0.488{\mu}m$ in Ext group, $5.286{\pm}1.604{\mu}m$ in Int-1 group, and $11.429{\pm}1.902{\mu}m$ in Int-2 group. In the pattern analysis, Int-1 and Int-2 group showed continuous axial displacement at 10,000 cycles. There was no declining pattern of axial displacement in the Ext group. Conclusion: The pattern of linear mixed model in Ext group showed no axial displacement. There were continuous axial displacements in abutment-implant assemblies in the Int-1 and Int-2 group at 10,000 cycles. More axial displacement was found in Int-2 group than in Int-1 group.

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

Study on the determination methods of the natural radionuclides (238U, 232Th) in building materials and processed living products (실내 건축자재 및 생활 가공제품 중 천연방사성핵종(238U, 232Th)의 농도 평가를 위한 분석법 연구)

  • Lee, Hyeon-Woo;Lim, Jong-Myoung;Lee, Hoon;Park, Ji-Young;Jang, Mee;Lee, Jin-Hong
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.149-160
    • /
    • 2018
  • A large number of functional living products are being produced for eco-friendly or health-promoting purposes. In the manufacturing process, such products could be adulterated with raw materials with high radioactivity, such as monazite and tourmaline. Thus, it is essential to manage raw materials and products closely related to the public living. For proper management, an accurate radioactivity data of the processed products are needed. Therefore, it is essential to develop a rapid and validated analytical method. In this study, the concentration of the radioactive $^{238}U$ and $^{232}Th$ in building materials (e.g., tile, cement, paint, wall paper, and gypsum board) and living products (e.g., health products, textiles, and minerals) were determined and compared by ED-XRF and ICP-MS. By comparing the results of both methods, we confirmed the applicability of the rapid screening and precise analysis of ED-XRF and ICP-MS. In addition, $^{238}U$ and $^{232}Th$ levels were relatively lower in building materials than in living products. Particularly, $^{232}Th$ content in 6 of 47 living products exceeded (maximum $8.2Bq{\cdot}g^{-1}$) the standard limit of $^{232}Th$ content in raw material ($1.0Bq{\cdot}g^{-1}$).

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

A Biomechanical Study on the Various Factors of Vertebroplasty Using Image Analysis and Finite Element Analysis (의료영상 분석과 유한요소법을 통한 추체 성형술의 다양한 인자들에 대한 생체 역학적 효과 분석)

  • 전봉재;권순영;이창섭;탁계래;이권용;이성재
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.171-182
    • /
    • 2004
  • This study investigates the biomechanical efficacies of vertebroplasty which is used to treat vertebral body fracture with bone cement augmentation for osteoporotic patients using image and finite element analysis. Simulated models were divided into two groups: (a) a vertebral body, (b) a functional spinal unit(FSU). For a vertebral body model, the maximum axial displacement was investigated under axial compression to evaluate the effect of structural integrity. The stiffness of each FE model simulated was normalized by the stiffness of intact model. In the case of FSU model, 3 types of compression fractures were formulated to assess the influence on spinal curvature changes. The FSU models were loaded under compressive pressure to calculate the change of spinal curvature. The results according to the various factors suggest that vertebroplasty has the biomechanical efficacy of the increment of structural reinforcement in a patient who has relatively high level of BMD and a patient with the amount of 15%, PMMA injection of the cancellous bone volume. The spinal curvatures after compression fracture simulation vary from 9$^{\circ}$ to 17$^{\circ}$ of kyphosis compared to that the spinal curvature of normal model was -2.8$^{\circ}$ of lordosis. These spinal curvature changes cause the severe spinal deformity under the same loading. As the degree of compressive fracture increases the spinal deformity also increases. The results indicate that vertebroplasty has the increasing effect of the structural integrity regardless of the amount of PMMA or BMD and the restoration of decreased vertebral body height may be an important factor when the compressive fracture caused the significant height loss of vertebral body.

Limb Salvage Surgery with Intramedullary Nailing and Cementization for the Bone Tumors of the Proximal Humerus (근위 상완골 골종양에서 골수강내 금속정과 골시멘트를 이용한 사지 구제술)

  • Kim, Han-Soo;Oh, Joo-Han;Nam, Woo-Dong;Rhie, Tae-Yon;Jeong, Jin-Young;Lee, Han-Koo;Lee, Sang-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.2
    • /
    • pp.53-60
    • /
    • 2000
  • Purpose : The purpose of the current study is to evaluate the functional and oncologic results of the limb salvage surgery with intramedullary nailing and cementization in malignant bone tumors of the proximal humerus. Materials and Methods : We reviewed 18 cases of limb salvage surgery of resection and reconstruction with an intramedullary nail and cement-molded humeral head for the malignant bone tumors of the proximal humerus, which performed between August, 1992 through the April, 1998. The diagnoses included the osteosarcoma in 7 patients, chondrosarcoma in 3, the recurrent giant cell tumor in 3, metastatic tumor in 3, multiple myeloma in one patient and the one patient with malignant fibrous histiocytoma. The mean age at the time of surgery was 38 years(range, 15-73 years). The mean follow-up period was 26 months(range, 6-67 months). Results : Average functional score by ISOLS evaluation system was 21.1(70.3%). There were 3 local recurrences and 5 distant metastases. There were one case of shoulder instability and one case of deep infection. The seven patients are continuously disease free state and seven patients are alive with disease. Four patients died from the disease. Conclusion : The limb salvage surgery with intramedullary nailing and cementization in the bone tumors of the proximal humerus may be considered an option for the malignant bone tumors of the proximal humerus in selected patients.

  • PDF

Recurrence Analysis of Giant Cell Tumor after Curettage and Cementation (거대 세포종에서 골 소파술 및 시멘트 충전술 후의 재발 분석)

  • Hahn, Soo-Bong;Lee, Won-Jun;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2004
  • Purpose: The purpose of this study is to investigate the characteristic of recurred giant cell tumor after bony curettage and cementation, and to review a way to prevent the recurrence. Materials and Methods : Thirty seven cases were analyzed, which were pathologically diagnosed giant cell tumor after diagnostic biopsy or surgical excision, followed by curative curettage, burring and cementation. Location, character, and time interval to recurrence were reviewed. Results: Thirteen out of thirty seven analyzed cases(35%) showed recurrence after primary curettage and cementation. The mean interval to recurrence was sixteen months(5 months to 43 months). Most of recurrence happened within the first two years except two cases. Among the recurred cases, eleven showed recurrence in the vicinity of window area. Two cases recurred in the depth of bone marrow, where cementation was made. The advantage of curettage and cementation is the immediate stability of the operation site, early rehabilitation, and early detection of recurrence. Furthermore, cementation is beneficial in that the cement-producing heat can eradicate the residual tumor burden. In this study, 85% of cases with insufficient curettage (for example, in cases where too small surgical window was made, or where there were anatomical difficulty in approaching the target tumor burden) showed recurrence. Conclusion: Bony curettage, burring and cementation is widely used as the primary curative modality for giant cell tumor. A few other modalities such as chemical cautery using phenol and $H_2O_2$; cryotherapy; and anhydroalcohol have also been introduced, but the benefit of these are still questionable. For some cases that relatively small surgical window was made due to anatomically complicated structures (such as ligament insertion or origin site) over the target tumor burden, unsatisfactory curettage and burring was made. This study showed high chance of recurrence after unsatisfactory curettage, and 85% of recurrence developed in the vicinity of the small window area. Most of the recurrence occurred within the first two years. It is concluded that sufficient window opening, extensive curettage and eradicative burring are key factors to prevent recurrence. Also, it should be reminded that careful and close observation should be made for at least the first two years after initial treatment for early detection of recurrence.

  • PDF

Surgical Treatment of Metastatic Tumor in Pelvis (골반부 전이성 종양의 수술적 치료)

  • Kim, Jae-Do;Park, Woong;Jo, Myung-Rae;Son, Jung-Whan;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2004
  • Purpose: We studied to decide the operative indication of the metastatic tumor in pelvis according to the oncologic results, the Eastern Cooperative Oncologic Group (ECOG) performance status and complication. Materials and methods: From May 1994 to May 2003, 9 patients who were performed on palliative treatment and 10 paitents on operative treatment due to metastatic tumor of pelvic bone were investigated. On palliative/operative group, the mean age of patients was 57.6/48.0 years old and the ratio of male to female was 5:4/7:3. Primary origins were 3 cases from kidney, 3 from cervix and 2 of lung, 2 of myeloma, 2 of Non-Hodgkin's Lymphoma, and 1 from breast, bladder, testis, prostate, stomach, liver and retroperitoneal leimyosarcoma respectively. The palliative treatment was performed in 5 cases with radiotherapy, 1 with chemotherapy, 2 with combined chemo-radiotherapy and 1 with percutaneous cementation. The operative methods were 1 case of bone cement insertion after curettage, 2 of Girdlestone with internal hemipelvectomy and 7 of reconstruction after wide excision. Reconstructions were done.: 1 case of bone cementation, 5 of autograft prosthesis composite with irradiation or pastuerization and 1 of saddle prosthesis. We have observed the oncologic results, the ECOG performance status and complication. Results: The oncologic results of palliative/operative groups are NED 0/1, AWD 2/6, DOC 1/2 and DOD 6/1. The ECOG performance status was changed from 1.5 into 4.3 in palliative group and from 2.6 into 2.2 in operative group. The complications were 3 cases of the prosthesis failure and 2 of infection. Conclusion: The indication of operation of metastatic pelvic tumor is decided in consideration of the patient's condition, the grade of malignancy in primary tumor and the life expectancy.

  • PDF

Characteristics of Polyester Polymer Concretes Using Spherical Aggregates from Industrial By-Products (III) (Using an Atomizing Steel Slag as a Filler and Fine Aggregate) (산업부산물 구형골재를 사용한 폴리에스테르 폴리머 콘크리트의 특성(III) (아토마이징 제강슬래그를 충전재와 잔골재로 사용))

  • Hwang, Eui-Hwan;Kim, Jin-Man
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.104-110
    • /
    • 2015
  • It is known that polymer concretes are 8~10 times more expensive than ordinary Portland cement concretes; therefore, in the production of polymer concrete products, it is very important to reduce the amount of polymer binders used because this occupies the most of the production cost of polymer concretes. In order to develop a technology for the reduction of polymer binders, smooth and spherical aggregates were prepared by the atomizing technology using the oxidation process steel slag (electric arc furnace slag, EAFS) and the reduction process steel slag (ladle furnace slag, LFS) generated by steel industries. A reduction in the amount of polymer binders used was expected because of an improvement in the workability of polymer concretes as a result of the ball-bearing effect and maximum filling effect in case the polymer concrete was prepared using the smooth and spherical atomized steel slag instead of the calcium carbonate (filler) and river sand (fine aggregate) that were generally used in polymer concretes. To investigate physical properties of the polymer concrete, specimens of the polymer concrete were prepared with various proportions of polymer binder and replacement ratios of the atomized reduction process steel slag. The results showed that the compressive strengths of the specimens increased gradually along with the higher replacement ratios of the atomized steel slag, but the flexural strength showed a different maximum strength depending on the addition ratio of polymer binders. In the hot water resistance test, the compressive strength, flexural strength, bulk density, and average pore diameter decreased; but the total pore volume and porosity increased. It was found that the polymer concrete developed in this study was able to have a 19% reduction in the amount of polymer binders compared with that of the conventional product because of the remarkable improvement in the workability of polymer concretes using the spherical atomized oxidation steel slag and atomized reduction steel slag instead of the calcium carbonate and river sand.