A Biomechanical Study on the Various Factors of Vertebroplasty Using Image Analysis and Finite Element Analysis

의료영상 분석과 유한요소법을 통한 추체 성형술의 다양한 인자들에 대한 생체 역학적 효과 분석

  • 전봉재 (인제대학교 의생명공학대학 의용공학과) ;
  • 권순영 (인제대학교 의생명공학대학 의용공학) ;
  • 이창섭 (인제대학교 부산 백병원 정형외) ;
  • 탁계래 (건국대학교 의과대학 의용공학) ;
  • 이권용 (세종대학교 기계항공우주공학) ;
  • 이성재 (인제대학교 의생명공학대학 의용공학과)
  • Published : 2004.06.01

Abstract

This study investigates the biomechanical efficacies of vertebroplasty which is used to treat vertebral body fracture with bone cement augmentation for osteoporotic patients using image and finite element analysis. Simulated models were divided into two groups: (a) a vertebral body, (b) a functional spinal unit(FSU). For a vertebral body model, the maximum axial displacement was investigated under axial compression to evaluate the effect of structural integrity. The stiffness of each FE model simulated was normalized by the stiffness of intact model. In the case of FSU model, 3 types of compression fractures were formulated to assess the influence on spinal curvature changes. The FSU models were loaded under compressive pressure to calculate the change of spinal curvature. The results according to the various factors suggest that vertebroplasty has the biomechanical efficacy of the increment of structural reinforcement in a patient who has relatively high level of BMD and a patient with the amount of 15%, PMMA injection of the cancellous bone volume. The spinal curvatures after compression fracture simulation vary from 9$^{\circ}$ to 17$^{\circ}$ of kyphosis compared to that the spinal curvature of normal model was -2.8$^{\circ}$ of lordosis. These spinal curvature changes cause the severe spinal deformity under the same loading. As the degree of compressive fracture increases the spinal deformity also increases. The results indicate that vertebroplasty has the increasing effect of the structural integrity regardless of the amount of PMMA or BMD and the restoration of decreased vertebral body height may be an important factor when the compressive fracture caused the significant height loss of vertebral body.

본 연구에서는 의료 영상과 유한요소 해석을 이용하여 골절된 척추체의 치료를 위해 골 시멘트를 주입하는 추체 성형술(vertebroplasty)에 영향을 미치는 여러 인자들에 대해 생체 역학적으로 분석하여 평가하고자 하였다. 의료 영상을 통해 구현된 모델들은 분석하고자 하는 인자에 대하여 크게 단분절과 다분절 유한요소 모델의 2 가지 형태로 구분하였다. 단분절 유한요소 모델을 통해 골다공증의 정도, 주입된 골 시멘트의 양, 골 시멘트의 주입량 및 환자에게 주입된 골 시멘트 양의 적절성을 평가하였으며, 골 시멘트의 주입이 척추체의 구조적 안정성에 미치는 효과를 분석하기 위하여 척추체 상종판에 수직 압축하중을 가하여 이때의 최대 수진 변위량을 분석하였다. 또한 단분절 척추체의 강성도(stiffness) 값을 산출한 뒤, 정상 상태의 척추체의 강성도 값으로 정규화 하였다. 다분절 유한요소 모델의 경우, 압박 골절 상태를 적용하여 척추 만곡의 변화가 인체에 미치는 영향을 분석하기 위하여 골절의 정도를 3 가지로 구현하였으며, 모델의 최상부에 압축 하중을 가한 후의 척추 만곡의 변화 정도를 분석하였다. 추체 성형술에 대한 다양한 인자들에 대한 분석 결과, 추체 성형술을 통해 환자의 골밀도가 상대적으로 높은 경우(BMD 50mg/$m\ell$이상)와 환자의 척추체 망상골 부피의 약 15%에 해당하는 골 시멘트 주입 시 가장 큰 척추체의 구조적 안정성의 증가 효과를 가져올 것으로 예측되었다. 또한 척추 골절이 미치는 영향에 대한 분석 결과, -2.8$^{\circ}$의 정상적인 후만곡을 가지는 T12∼L2 운동 분절이 골절의 모델링 후 약 9∼17$^{\circ}$의 큰 전만곡을 가지게 되었으며 이러한 척추 만곡의 변화는 동일한 하중 하에서 급격한 척추 만곡의 변화를 야기하는 것으로 나타났다. 또한 골절의 정도가 심할수록 척추 변형은 더욱 크게 증가하는 것으로 나타났다. 이러한 연구 결과들로부터, 전반적으로 추체 성형술은 골 시멘트의 주입량 또는 골밀도에 상관없이 약화된 척추체의 자체의 구조적 안정성의 증가 효과를 가져왔으며 골절로 인해 추체의 높이가 손상되었을 경우 이를 회복하는 것이 중요한 인자의 하나임을 나타내는 결과로 사료되어진다.

Keywords

References

  1. Neurochirurgie v.233 Note preliminaire sur le traitement des angiomes vertebraux par vertebroplastie acrylique percutanee P. Galibert;H. Deramond;P. Rosat(et al.)
  2. Am J Neuroradiol. v.18 Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects ME. Jensen;AJ Evans;JM Mathis(et al.)
  3. J Rheumatol. v.39 Longterm observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty F. Grados;C. Depriester;G. Cayrolle(et al.) https://doi.org/10.1093/rheumatology/39.12.1410
  4. Spine v.22 Future directions. Augmentation of osteoporotic vertebral bodies M. P. Bostrom;J. M. Lane
  5. Spine v.24 Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures AG. Tohmeh;JM. Mathis;DC. Fenton(et al.) https://doi.org/10.1097/00007632-199909010-00004
  6. Clin Orthop. v.295 Thermal aspects of the use of polymethylmethacrylate in large metaphyseal defects in bone. A clinical review and laboratory study M. C. Leeson;S. B. Lippitt
  7. Bone v.25 An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty S. M. Belkoff;M. Maroney;D. C. Fenton(et al.) https://doi.org/10.1016/S8756-3282(99)00128-3
  8. Radiother Oncol. v.1 The relationship between heating time and temperature: its relevance to clinical hyperthermia S. B. Field;C. C. Morris https://doi.org/10.1016/S0167-8140(83)80020-6
  9. Bone v.25 no.S Temperature elevation caused by bone cement polymerization during vertebroplasty H. Deramond;N. Wright;S. Belkoff
  10. Spine v.26 Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty M. Liebschner;W. Rosenberg;T. Keaveny https://doi.org/10.1097/00007632-200107150-00009
  11. Procs ISSLS U. Berlemann(et al.)
  12. Am J Neuroradiol. v.22 An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty S. M. Belkoff;J. M. Mathis;H. Deramond(et al.)
  13. Spine v.26 Initial outcome and efficacy of "Kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures I. Lieberman;S. Dudeney;M. Reinhardt(et al.) https://doi.org/10.1097/00007632-200107150-00026
  14. Spinal Adaptations in Response to Interbody Fusion Systems: A Theoretical Investigation N. Grosland
  15. J. Comput Assist Tomogr. v.14 Mechanical properties of trabecular bone from the proximal femur: A quantitative CT study J. Lotz;T. Gerhart;W. Hayes https://doi.org/10.1097/00004728-199001000-00020
  16. Spine v.22 no.24S Biomechanics of osteoporosis and vertebral fracture E. Myers;S. Wilson https://doi.org/10.1097/00007632-199712151-00005
  17. Acta Orthop Scand. v.55 Bone cement, thermal injury and the radiolucent zone B. Mjoberg;H. Pettersson;R. Rosenqvist(et al.) https://doi.org/10.3109/17453678408992403
  18. Spine v.9 no.2 Stress analysis of the lumbar disc-body unit in compression S. Shirazi-ADL;S. Shrivastava;A. Ahmed https://doi.org/10.1097/00007632-198403000-00003
  19. J Korean Orthop.. Assoc v.33 no.7 Spinal dimensions and shape variation in Korean - radiographic quantitative morphometry N. Kim;S. Moon;H. Lee(et al.)
  20. Spine v.11 no.2 A study of vertebra and disc geometric relations of the human cervical and lumbar spine I. Gilad;M. Nissan. https://doi.org/10.1097/00007632-198603000-00010
  21. Spine v.14 Segmental analysis of the sagittal plane alignment of the normal thoracic and lumbar spines and thoracolumbar Junction M. Bernhardt;K. H. Bridwell https://doi.org/10.1097/00007632-198907000-00012
  22. Spine v.5 Relation between the structure of the annulus fibrosus and the function and failure of the intervertebral disc D. Hickey;D. Hukins https://doi.org/10.1097/00007632-198003000-00004
  23. Spine v.7 Biological changes in the annulus flbrosus in patients with low-back pain R. Stevens;R. Ryvar;W. Robertson(et al.) https://doi.org/10.1097/00007632-198205000-00006
  24. Spine v.7 Collagenolytic enzyme systems in human intervertebral disc K. Sedowofia;I. Tomlinson;J. Weiss(et al.) https://doi.org/10.1097/00007632-198205000-00005
  25. J Biomech. v.9 Mechanical behavior of the human annulus fibrosus H. Wu;R. Yao https://doi.org/10.1016/0021-9290(76)90132-9
  26. Strength of Biological Materials H. Yamada
  27. Spine v.8 Deformation of the vertebral end-plate under axial loading of the spine P. Brinckmann;W. Frobin;E. Hierholzer(et al.) https://doi.org/10.1097/00007632-198311000-00007
  28. Am J Epidemiol. v.129 Eidemiology of vertebral fractures in women L. Melton;S. Kan;K. Frye(et al.) https://doi.org/10.1093/oxfordjournals.aje.a115204