A Study on the Analysis of Fire Risk and Field Survey for FilottI Structures (필로티 구조물의 화재위험성 분석 및 현장조사에 관한 연구)

  • Han, Ji-Woo;Lee, Byeong-heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.45-46
    • /
    • 2018
  • The fire at the pilotis parking lot shows the fire propagation paths that are propagated to the ceiling materials and insulation materials and propagated through the external walls. In addition, there is a high risk of fire caused by vehicles with high combustion loads spreading throughout the parking lot. In particular, the omission of the ceiling materials at the parking lot in recent fire cases has contributed to the spread of the fire. In this study, the combustion performance of the ceiling materials between the insulation material and the vehicle is considered to prevent fire from spreading. Based on field research, the type of ceiling material used in the piloti structure showed that SMC ceiling materials have the highest percentage. Combustion performance test (KS F ISO 5660-1) was carried out on the SMC ceiling materials and the AL ceiling materials to review the fire safety of the ceiling finish based on the field investigation. The results of the test showed that the SMC ceiling materials has a THR 28.973[MJ/㎡] and peek HRR 273.93 [kW/㎡], while the AL ceiling material has a THR 0.584[MJ/㎡] and peek HRR 15.215[kW/㎡].

  • PDF

A Study of Penetration Depth into Ceiling Materials containing Asbestos according to Dilution Rate of Scattering Prevention Agent (석면 함유 천장재의 안정화제 희석에 따른 침투깊이 연구)

  • Shin, Hyungyoo;Choi, Youngkue;Jeon, Boram;Ha, Jooyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.82-88
    • /
    • 2015
  • Objectives: This study is designed to analyze the penetration performance into ceiling materials containing asbestos of scattering prevention agents and investigate the change in penetration depth and viscosity according to the dilution rate of anti-scattering agents diluted with distilled water. Methods: Five different types of scattering prevention agents were spread on plate-type asbestos ceiling materials. The penetration depth of each coated ceiling material was measured by energy dispersive spectroscopy (EDS) analysis, based on X-ray fluorescence (XRF) results of the non-coated ceiling materials. Test equipment installed the ceiling materials and 60 minutes were collected at a flow rate of $10{\ell}/min$ at a filter of 25 mm. Results: An EDS analysis of the cross-section of ceiling materials constructed with a scattering prevention agent revealed that potassium is detected in the process of penetrating hardener solidification and this element could be an indicator for infiltration. When anti-scattering agents with different viscosities were constructed and the penetration depth was analyzed by potassium detection assessment using EDS, the depth results with viscosities of 5.0, 2.5, and 1.9 cP were 98.5, 103, and $147{\mu}m$, respectively. Penetration performance improved with decrease in viscosity. Conclusions: For asbestos ceiling materials, it is concluded that a higher dilution rate of the scattering prevention agent leads to lower viscosity, and hence a deeper penetration depth from $156{\mu}m$ to 3 mm. The asbestos anti-scattering properties according to the penetration depth will be confirmed through further study.

Design of Working Process for Ceiling Glass Installation Robot (천장유리 설치로봇의 자동화 공정설계)

  • Yoo, Bo-Hyun;Lee, Seung-Yeol;Gil, Myeong-Su;Lee, Sang-Heon;Lee, Kye-Young;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.837-842
    • /
    • 2007
  • Since construction materials have been towards larger and heavier, the rate of accident associated with installation works of heavy construction materials is increasing. Installation works of heavy construction materials lead to frequent accidents, increasing the WMSDs(Work-Related Musculo-Skeletal Disorders) in construction site. In case of installation work of heavy glass ceiling, the rate of accidents such as falling and collision is increasing as well. This paper describes a ergonomic design of working platform(deck) in a glass ceiling installation robot. As well as, a design of working process is considered to accomplish an efficient installation work. As a result of the design, an installation work of heavy glass ceiling by the robot will be expected safety assurance and retrenchment of the construction cost and period.

  • PDF

Development of ceiling construction methods reduced floor impact sound (바닥충격음 저감이 가능한 천장 공법 개발)

  • Kim, kyungho;Kim, sunghoon;Ryu, jongkwan;Lee, jongin;Kim, yongmin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

A Study of Asbestos Stabilizer Treatment Considering the Actual Environment of Ceiling Materials (실제 환경을 고려한 천장텍스의 석면안정화제 처리 연구)

  • Shin, Hyungyoo;Choi, Youngkue;Jeon, Boram;Ha, Jooyeon;Sun, Yleshik;Park, Whame
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2016
  • Objectives: This study aimed to confirm the optimal processing conditions of the asbestos stabilizer by considering various actual environments at the time of stabilization treatment of the ceiling materials containing asbestos with asbestos stabilizer. Methods: The anti-scattering performances of the asbestos stabilizer were confirmed by considering the method and quantity of the asbestos stabilizer treated, comparing the loss weight by measuring the weight of ceiling materials prior to and after having treated 30, 50, 100, 200, and 400 of stabilizer using the brush and spray. The effects of backside dust and steel frame structure on the performances of the stabilizer was also confirmed by comparing samples with and without the dust on the rear surface removed by wiping the ceiling material specimens and the blinding treatment simulated by using tape. Results: The asbestos stabilization treatment using the brush method in comparison with the use of a spray has reduced stabilizer loss, resulting in better anti-scattering performance. In addition, the stabilizer loss is increased with increasing treatment quantity; as a result, treating a larger quantity of stabilizer does not improve the performance. For the conditions related to ceiling materials, the anti-scattering performance is enhanced by removing the backside dust and spreading the stabilizer evenly on the masking portion by steel frame structures. Conclusions: Based on these results, it is determined that the appropriate choice of the tool used for the treatment of the asbestos stabilizer and the appropriate quantity of asbestos stabilizer were needed at the time of actual stabilization processing of the ceiling materials containing asbestos. Moreover, this study confirmed that preliminary processing and verification of the structure at which the ceiling materials are installed can enhance the effectiveness of prevention of the scattering of asbestos into the air.

The Fundamental study on Development of Ceiling materials using the Zeolite and Stone dust, Sludge (제올라이트와 석분 및 슬러지를 이용한 천장재의 개발에 관한 기초적 연구)

  • 임병호;류희정;최영준;이승조;김태곤;박정민;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.777-784
    • /
    • 1997
  • This paper is fundamental study to develop ceiling materials, using the properties of Zeolite, stone dust and sludge for the purpose of prevention of environmental pollution and reuse of industrial wastes. According to latin square method, We estimated to the significant level ad optimum level for a significant factor, and investigated to the significant degree to extend each factor for required capacity. Thus, we investigated for required capacity in ceiling material such as, compressive and bending strength, absorptivity and thermal conductivity.

  • PDF

A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구)

  • Ki, No-Gab;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

A Study on the Application of Gypsum Board through the Application of Fire Resistance Ceiling Structure (내화천장구조 적용을 통한 석고보드 활용 확대에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.217-218
    • /
    • 2019
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system, in these cases, gypsum boards are mostly used as ceiling materials. The purpose of this study was to explain the possibility of expanding the use of gypsum boards by securing fire resistance performance of these ceilings.

  • PDF

Performance Evaluation of Water Vapour Adsorption/Desorption Property for a Building Material by Mock up Test (실물시험을 통한 흡방습 건축자재의 성능평가)

  • Kim, Hea Jeong;Song, Kyoo Dong;Lee, Yun Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.53-58
    • /
    • 2009
  • There are increasing developments and uses of functional building materials are recently developed and introduced to the test method for the materials. Especially, moisture problem has a major role are also being established in indoor air quality problems. The purpose of this study is to evaluate the water vapour adsorption/desorption property of a ceiling material. The variation of the temperature and moisture were measured with the application materials by mock up test based on JIS 1470-1. The result shows that water vapour adsorption/desorption property of ceiling material is appeared in changes of moisture adsorption and desorption in comparison with that of a general ceiling material. Therefore, in case of decreasing and increasing in humidity, these materials can be used as an finishing material to sustain comfort condition.

A Study on the Reduction Characteristics of Floor Impact Sound Insulation Due to the Ceiling Frame Structures in Apartment Houses (공동주택의 천장틀구조 변화에 따른 바닥충격음 차음특성 연구)

  • 정환욱;기노갑;송민정;김선우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.573-580
    • /
    • 2002
  • Generally the ceiling frame of apartment house is made of wood. But the wood frame has several problems due to the natural properties such as distortion by shrink, low fire resistance and material loss in the construction field. And it has some defections in sound insulation performance. Therefore it is necessary to develop a new method that can be used as a ceiling frame. This study aims to analyze and to compare the sound insulation characteristics against the floor impact sound between wood ceiling frame and M-bar frame which is made of steel. The results of this study are like these. M-bar frame is more effective than wood ceiling frame in sound insulation. And sound absorbing or sound insulation materials which can be Put on gypsum board are helpful to improve floor impact sound insulation performance.