• 제목/요약/키워드: ceiling effect

검색결과 164건 처리시간 0.027초

파이프 비닐온실용 권취식 창개폐기의 개발 (Development of roll - up ventilation system for pipe- constructed plastic film greenhouse)

  • 이기명;박규식;김유일;김태홍
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF

선박용 판넬의 음향투과손실(STL)의 실험실법 측정과 Mock-up 측정값의 비교 (Comparison of Panel STLs for Ships Measured in Laboratory and Mock-up)

  • 김현실;김봉기;차선일;김영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.69-72
    • /
    • 2005
  • In this paper, FSTL(field sound transmission loss) measured in the mock-up is studied and compared to the STL measured in laboratory. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t or 50t panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where the effects of U/T, sealing, panel thickness, ceilings are studied. It is shown that the effect of ceiling thickness is negligible and FSTL is lower than STL by 5-7 dB due to several flanking paths.

  • PDF

기능성 모듈이 적용된 천장 매립식 냉난방 유닛의 유동특성 평가에 관한 연구 (A Study on the Evaluation of Flow Characteristics of Heating and Cooling Unit Installed within Ceiling with Functional Modules)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1131-1136
    • /
    • 2006
  • In this study, an experimental and numerical analysis on the flow characteristics of heating and cooling unit installed within ceiling with functional modules was carried out. And the flow characteristics of the heating and cooling unit was investigated with the main parameters such as each filter and inside structure. The experimental results show the possibility of medium filter application. And the numerical results show that the effect of improved inside structure of heating-cooling and air-conditioning unit on flow distribution.

  • PDF

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

건축공간에서의 원근기법 이용에 관한 연구(1) - 고구려 무덤과 그 벽화를 중심으로 - (A Study on the Utilization of Perspective Representation in a Construction Space - centering on the tombs and mural paintings of Koguryo -)

  • 홍재동;임충신
    • 건축역사연구
    • /
    • 제6권3호
    • /
    • pp.129-143
    • /
    • 1997
  • The perspective representation and its effect that appeared in the tombs and mural paintings of koguryo are summarized as follows: First, The inside structure of the tombs is likely to show the deepness effect, placing each function in the front and both sides centering around the mane pillars and creating the boundaries and the spaces that have various visibility between the inside and outside spaces of the structure just like a traditional Korean house shows. In addition, The deepness effect is emphasized by suggesting that the spaces are countinued with a storage attached behind the main house or by forming the level and deployment in a narrow space like the scene that a large array is looked out from the main house. Second, The deepness effect is expressed by making the form of ceiling turn to a vertical space of an ascending image, constructing it just as the lotus lamp ceiling of a wooden architecture or drawing it just like the imaginary heavenly world with the sun the moon and mythical fairies and animals spread in it. Thried, The perspective effect is disclosed by drawing the mural pictures in an equally set bird's-eye view without regard to the disfance proportion according to the conceptual visualization which is not a visual penetration, adopting the multiple view points and moving view points that are moving around as an important manner of seeing. Fourth, The deepness effect is emphasized through the scene of changing spaces when they are looked out far or looked into depending on a viewpoint of the daily life by forming the fromes of paintings that we made up with actual pillars, Du Gong, crossbeams or that are painted in most tombs. Fifth, The rich spatial senses are reflected by originating the characters of the three directions, level, deployment and ascending. An example which can support the conclusion of this study can be given here. that is, the construction ground plan of a dwelling house of a nobleman at the end of Koguryo as a remain which was excavated at Dongdae Ja in Jip An.

  • PDF

석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구 (Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials)

  • 하주연;신현규
    • 한국산업보건학회지
    • /
    • 제30권1호
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

쉴드 TBM터널 상부 지반 연약대 전기탐사 (Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling)

  • 정현기;박철환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

Comparison of Sound Transmission Loss of Panels Used in Ship Cabins for Field and Laboratory Measurements

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권1E호
    • /
    • pp.9-15
    • /
    • 2009
  • In this paper, FSTL (Field Sound Transmission Loss) measured in a mock-up simulating ship cabins is studied. A mock-up is built by using 6 mm steel plate, and two identical cabins are made where 25 mm or 50 mm sandwich panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where effects of wall and ceiling panel thickness, and presence of a unit toilet on FSTL are investigated. It is found that the effect of unit toilet on FSTL is at most 1 dB. From the comparison of FSTL for panels of the same thickness of 50 mm, it is observed that panel having inside air cavity of 10 mm shows higher STL than that of the panel without air cavity. Comparison of FSTL for panels of 50 mm and 25 mm thickness shows that dependency on surface density predicted by mass law is not observed. The sandwich panels act as a mass-spring system, which shows a resonant mode that cannot be explained by the mass law. It is also found that STL from laboratory test is higher than FSTL by 5- 10 dB, which can be explained by flanking structure-borne noise transmission path such as ceiling, floor and corridor-facing wall.

기업 관리직의 젠더 격차와 "유리천장" 분석 (An Analysis of the Managerial Level's Gender Gap and "Glass Ceiling" of the Corporation)

  • 조혜원;함인희
    • 한국사회정책
    • /
    • 제23권2호
    • /
    • pp.49-81
    • /
    • 2016
  • 본 논문은 현재 기업의 관리직 내 젠더 격차 및 유리천장 현황을 점검해보고, 향후 여성고용의 질적 수준을 제고하기 위한 개선 방안을 모색하는데 목적이 있다. 이를 위해 조직 내 여성 구성원의 양적 증대가 갖는 의미를 중점적으로 다룬 선행 논의들을 정리해보고, 여성가족부에서 수행한 '여성인력패널조사' 3차년도(2010년 시행) 데이터를 활용하여 기업 내 관리직급의 젠더 격차 현황과 더불어 여성이 직면하고 있는 "유리천장"의 실재를 다각도로 검증해보았다. 그 결과 관리직 내 젠더격차가 공고하게 유지되고 있는 동시에, 특별히 유리천장은 '보다 상위직급으로 승진할 때 강화되는 현상'이 아니라 경력초기단계에 이미 존재하고 있음이 확인되었다. 이로부터 추출해낸 정책적 시사점은 다음과 같다. 첫째, 여성관리자의 경우 과장직급 이후부터 파이프라인의 단절현상이 발견된 바, 향후 상위직 승진을 위한 인력풀의 안정적 확보가 필수적이다. 둘째 유리천장이 경력단계 매우 초기부터 시작되는 것으로 나타난 바 이를 극복하기 위한 현실적 방안으로서, 출산 및 육아휴직 후 복귀 프로그램 지원, 경력개발 및 리더십 개발 프로그램의 제도화, 여성 관리자 간 네트워킹 및 멘토링, 외국계 기업의 성공 사례 도입 등 보다 구체적 노력이 시급히 요망된다. 셋째, 정부차원에서 여성고용율과 여성관리자비율을 모니터링 하는 적극적고용개선조치 기준은 여전히 소극적으로 설정된 바, 선진국 수준으로 가기 위한 궁극적 목표지점(stretching goal)을 세운 후 단계적으로 관리할 필요성이 제기된다. 넷째 여성고용과 관련해서 양적 지표관리에만 치중하기보다는, 제도와 프로세스 및 조직문화에 대한 점검, 여성 개인의 경험 및 체감 지표의 개발 등 질적 요소와 더불어 여성고용정책 내실화 및 질적 제고, 장기적 관점에서의 정책 체계화 등이 그 어느 때 보다 필요하리라 생각된다.

공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF