• Title/Summary/Keyword: ceiling effect

Search Result 163, Processing Time 0.163 seconds

Vibration isolation effect of floor impact sound by ceiling structure (바닥충격음에서의 천장구조에 따른 진동절연 효과)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

Development of ceiling construction methods reduced floor impact sound (바닥충격음 저감이 가능한 천장 공법 개발)

  • Kim, kyungho;Kim, sunghoon;Ryu, jongkwan;Lee, jongin;Kim, yongmin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

The effect of a slat ceiling on the acoustics of a small performance space (슬랫천장이 소규모실의 음향에 미치는 영향)

  • Oh, Yedam;Lee, Hyojin;Jeong, Daeup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.363-368
    • /
    • 2018
  • Recently a slat type ceiling is widely used in various spaces, such as music performance spaces and concourse of airport and a general reception area of a building. However, it is hard to find a proper design guideline or material useful in designing such spaces, due to the lack of relevant researches on the effect of a slat ceiling on room acoustics. The present work investigated the effect of a slat type ceiling using a physical scale model method. A 1/20 scale model of a small shoe-box type music performance hall was built and a slat ceiling with different configurations was installed. 6 cases of different ceiling configurations were considered with the combination of 2 slat ceiling height cases and 3 distance cases between slats. The effect of a slat ceiling on the acoustics of a room was evaluated by measuring reverberance($T_{30}$), intelligibility and clarity($D_{50}$ and $C_{80}$), and loudness(G and $G_{80}$).

Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change

  • Lee, Tae-Jin;Cheong, Chelim
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.6
    • /
    • pp.393-400
    • /
    • 2017
  • Objectives: To relieve the financial burden faced by households, the Korean National Health Insurance (NHI) system introduced a "copayment ceiling," which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients' income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. Methods: This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP) payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. Results: The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. Conclusions: The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

Shaking table tests on seismic response of backdrop metal ceilings

  • Zhou, Tie G.;Wei, Shuai S.;Zhao, Xiang;Ma, Le W.;Yuan, Yi M.;Luo, Zheng
    • Steel and Composite Structures
    • /
    • v.32 no.6
    • /
    • pp.807-819
    • /
    • 2019
  • In recent earthquakes, the failure of ceiling systems has been one of the most widely reported damage and the major cause of functionality interruption in some buildings. In an effort to mitigate this damage, some scholars have studied a series of ceiling systems including plaster ceilings and mineral wool ceilings. But few studies have involved the backdrop metal ceiling used in some important constructions with higher rigidity and frequency such as the main control area of nuclear power plants. Therefore, in order to evaluate its seismic performance, a full-scale backdrop metal ceiling system, including steel runners and metal panels, was designed, fabricated and installed in a steel frame in this study. And the backdrop metal ceiling system with two perimeter attachments variants was tested: (i) the ends of the runners were connected with the angle steel to form an effective lateral constraint around the backdrop metal ceiling, (ii) the perimeter attachments of the main runner were retained, but the perimeter attachments of the cross runner were removed. In the experiments, different damage of the backdrop metal ceiling system was observed in detail under various earthquakes. Results showed that the backdrop metal ceiling had good integrity and excellent seismic performance. And the perimeter attachments of the cross runner had an adverse effect on the seismic performance of the backdrop metal ceiling under earthquakes. Meanwhile, a series of seismic construction measures and several suggestions that need to be paid attention were proposed in the text so that the backdrop metal ceiling can be better applied in the main control area of nuclear power plants and other important engineering projects.

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

A Case Study on the Effect of Price Ceiling Regulation on the New Apartment Price (분양가상한제 적용여부에 따른 아파트 분양가 비교분석 -부산광역시 민간택지 사례를 중심으로-)

  • Ryu, Je-Moon;Shim, Jae-Heon;Lee, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3747-3756
    • /
    • 2012
  • This paper examines the effect of price ceiling regulation on the new apartment price. The analysis procedure of the study is divided into two parts, which stand for a case study on the effect of price control on the new apartment price and the survey of real estate experts on price ceiling regulation. The empirical results of our case study show that the selling price under price ceiling regulation is generally lower than that in the situation of price deregulation, in terms of the land development expense and construction cost. With regard to the survey results, more than half of respondents have opinions that price ceiling regulation has an impact on the new apartment price and lowers the price. They are equally divided pro and con regarding the problem of keeping or discarding the regulation.

Glass ceiling in arts and culture professionals: Between J and R industries (문화예술분야 전문인력에 대한 유리천장효과 분석: J산업과 R산업 중심으로)

  • Chan, Jong-Sub;Heo, Shik
    • Review of Culture and Economy
    • /
    • v.21 no.2
    • /
    • pp.3-28
    • /
    • 2018
  • This study focuses on analyzing the glass ceiling effect in arts and culture professionals through the quintile decomposition applied to the RIF unconditional quantile regression and Oaxaca-Blinder decomposition technique. From the industrial viewpoint, we divide arts and culture professionals into cultural contents professionals(large category J industry) and arts professionals(large category R industry). For our analysis, we employ the pooling data of 'Wage Structure Survey' from 2009 to 2016. Our results are summarized as follows. First, as OLS wage decomposition showed that the gender wage gap among the arts professionals was lower than cultural contents professionals, but the discrimination portion of total gender wage gap was larger. Second, from quintile regression decompositions, the glass ceiling effects of two types of professionals showed different results. Cultural contents sector was observed with the "steady glass ceiling effect" as the portion of the discrimination was continuously increased, while the arts sector was observed with the "limited glass ceiling effect" as the discrimination had drastically increased in the 80s and 90s.

The Effect of Glass Ceiling Induced Factors and Perception on Job Commitment: Focusing on the Comparison between Local Medical Practitioners and Private Medical Practitioners (승진장벽(Glass Ceiling)의 유발요인과 지각이 직무몰입에 미치는 영향 분석: 방의료원과 민간의료원의 종사자들의 비교를 중심으로)

  • Suh, Kyung-Do
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.225-232
    • /
    • 2016
  • The purpose of this study is to analyze the effect of the glass ceiling induction factors on the improvement of the job Commitment on the glass ceiling perception and to analyze the effect of the organizational Commitment on the influence of the local medical institute and private medical institute employees. Purpose. As a research method, structural equation model analysis was carried out to investigate the influence relationship of each factor. In particular, multiple group analysis was performed to analyze the difference of influence relations between public and private medical personnel. Respectively. Result, First, empirical studies on the effect of the glass ceiling inducing factors on job Commitment showed that job Commitment was influenced by stereotype and organizational culture, and the magnitude of the influence was different. Second, the employees of the room medical center were influenced by perceived promotion, job placement, education and training, reward, and job satisfaction. Third, in the hypothesis that job Commitment will be affected by the perception of glass ceiling, only the workers of the private medical center showed significant results. Based on the results of this study, it will be necessary to plan policies to improve the perception of the glass ceiling phenomenon and improve its status in order to improve the personnel and system that women workers in the medical field can enter more senior management positions.

Performance evaluation of suspended ceiling systems using shake table test

  • Ozcelik, Ozgur;Misir, Ibrahim S.;Saridogan, Serhan
    • Structural Engineering and Mechanics
    • /
    • v.58 no.1
    • /
    • pp.121-142
    • /
    • 2016
  • The national standard being used in Turkey for suspended ceiling systems (SCS) regulates material and dimensional properties but does not contain regulations regarding installation instructions which cause substandard applications of SCSs in practice. The lack of installation instructions would potentially affect the dynamic performance of these systems. Also, the vast majority of these systems are manufactured using substandard low-quality materials, and this will inevitably increase SCS related damages during earthquakes. The experimental work presented here focuses on the issue of dynamic performance of SCSs with different types of carrier systems (lay-on and clip-in systems), different weight conditions, and material-workmanship qualities. Moreover, the effects of auxiliary fastening elements, so called seismic perimeter clips, in improving the dynamic performance of SCSs were experimentally investigated. Results show that clip-in ceiling system performs better than lay-on system regardless of material and workmanship qualities. On the other hand, the quality aspect becomes the most important parameter in affecting the dynamic performance of lay-on type systems as opposed to tile weights and usage of perimeter clips. When high quality system is used, tile weight does not change the performance of lay-on system, however in poor quality system, tile weight becomes an important factor where heavier tiles considerably decrease the performance level. Perimeter clips marginally increase the dynamic performance of lay-on ceiling system, but it has no effect on the clip-in ceiling system under the shaking levels considered.