• Title/Summary/Keyword: ccd

Search Result 2,859, Processing Time 0.031 seconds

Earthquake risk assessment of concrete gravity dam by cumulative absolute velocity and response surface methodology

  • Cao, Anh-Tuan;Nahar, Tahmina Tasnim;Kim, Dookie;Choi, Byounghan
    • Earthquakes and Structures
    • /
    • v.17 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • The concrete gravity dam is one of the most important parts of the nation's infrastructure. Besides the benefits, the dam also has some potentially catastrophic disasters related to the life of citizens directly. During the lifetime of service, some degradations in a dam may occur as consequences of operating conditions, environmental aspects and deterioration in materials from natural causes, especially from dynamic loads. Cumulative Absolute Velocity (CAV) plays a key role to assess the operational condition of a structure under seismic hazard. In previous researches, CAV is normally used in Nuclear Power Plant (NPP) fields, but there are no particular criteria or studies that have been made on dam structure. This paper presents a method to calculate the limitation of CAV for the Bohyeonsan Dam in Korea, where the critical Peak Ground Acceleration (PGA) is estimated from twelve sets of selected earthquakes based on High Confidence of Low Probability of Failure (HCLPF). HCLPF point denotes 5% damage probability with 95% confidence level in the fragility curve, and the corresponding PGA expresses the crucial acceleration of this dam. For determining the status of the dam, a 2D finite element model is simulated by ABAQUS. At first, the dam's parameters are optimized by the Minitab tool using the method of Central Composite Design (CCD) for increasing model reliability. Then the Response Surface Methodology (RSM) is used for updating the model and the optimization is implemented from the selected model parameters. Finally, the recorded response of the concrete gravity dam is compared against the results obtained from solving the numerical model for identifying the physical condition of the structure.

Optical encryption system using random divided image and joint transform correlator (무작위 분할 영상과 결합변환 광 상관기를 이용한 암호화 시스템)

  • 최상규;서동환;신창목;김수중;배장근
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.636-642
    • /
    • 2003
  • We proposed the optical system using two divided halftone images to hide the original image and a joint transform correlator. The encryption procedure is performed by the Fourier transform of the product of each divided image by visual cryptography and the same random image which is generated by computer processing. As a result, we can obtain two Fourier divided images which are used as the encrypted image and the decrypting key, respectively. In the decryption procedure, both the encrypted image and the decrypting key are located on the joint input plane. Then the original image is reconstructed on a CCD camera which is located in the output plane. An autocorrelation term of joint transform correlator contributes to decrypt the original image. To demonstrate the efficiency of the proposed system, computer simulations and noise analysis are performed. The result show that the proposed system is a very useful optical certification system.

Optical Design of A Compact Imaging Spectrometer for STSAT3

  • Lee, Jun-Ho;Jang, Tae-Seong;Yang, Ho-Soon;Rhee, Seung-Wu
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.262-268
    • /
    • 2008
  • A compact imaging spectrometer (COMIS) for use in the STSAT3 microsatellite is currently under development. It is scheduled to be launched into a low Sun-synchronous Earth orbit (${\sim}700km$) by the end of 2010. COMIS was inspired by the success of CHRIS, which is a small hyperspectral imager developed for the ESA microsatellite PROBA. COMIS is designed to achieve nearly equivalent imaging capabilities of CHRIS in a smaller (65 mm diameter and 4.3 kg mass) and mechanically superior (in terms of alignment and robustness) package. Its main operational goal will be the imaging of Earth's surface and atmosphere with ground sampling distances of ${\sim}30m$ at the $18{\sim}62$ spectral bands ($4.0{\sim}1.05{\mu}m$). This imaging will be used for environmental monitoring, such as the in-land water quality monitoring of Paldang Lake, which is located next to Seoul, South Korea. The optics of COMIS consists of two parts: imaging telescope and dispersing relay optics. The imaging telescope, which operates at an f-ratio of 4.6, forms an image (of Earth's surface or atmosphere) onto an intermediate image plane. The dispersion relay optics disperses the image and relay it onto a CCD plane. All COMIS lenses and mirrors are spherical and are made from used silica exclusively. In addition, the optics is designed such that the optical axis of the dispersed image is parallel to the optical axis of the telescope. Previous efforts focused on manufacturing ease, alignment, assembly, testing, and improved robustness in space environments.

A New X-Ray Image Sensor Utilizing a Liquid Crystal Panel (새 구조의 액정 엑스선 감지기)

  • Rho, Bong-Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • We developed a new x-ray image sensor utilizing a reflection-mode liquid crystal panel as its sensitive element, and tested its functionality by using it to obtain an x-ray image of a printed circuit board. In the liquid crystal x-ray image sensors hitherto reported, the liquid crystal layer is in direct contact with the photoconductive film which is deposited on a glass substrate. In the fabrication of the new x-ray image sensor, a liquid crystal panel is fabricated in the first step by using a pair of glass plates of a few centimeters thicknrss. Then one of the glass substrates is ground until its thickness is reduced to about $60\;{\mu}m$. After polishing the glass plate, dielectric films for high reflectance at 630 nm, a film of amorphous selenium for photoconduction, and a transparent conductive film for electrode are deposited in sequence. The new x-ray image sensor has several merits: primarily, fabrication of a large area sensor is more easily compared with the old fashioned x-ray image sensors. Since the reflection type liquid crystal panel has a very steep response curve, the new x-ray sensor has much more sensitivity to x-rays compared with the conventional x-ray area sensor, and the radiation dosage can be reduced down to less then 20%. By combining the new x-ray sensor with CCD camera technology, real-time x-ray images can be easily captured. We report the structure, fabrication process and characteristics of the new x-ray image sensor.

CDSS enabled PHR system for chronic disease patients (만성 질병환자를 위한 CDSS를 적용한 PHR 시스템)

  • Hussain, Maqbool;Khan, Wajahat Ali;Afzal, Muhammad;Ali, Taqdir;Lee, Sungyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1321-1322
    • /
    • 2012
  • With the advance of Information Technology (IT) and dynamic requirements, diverse application services have been provided for end users. With huge volume of these services and information, users are required to acquire customized services that provide personalized information and decision at particular extent of time. The case is more appealing in healthcare, where patients wish to have access to their medical record where they have control and provided with recommendation on the medical information. PHR (Personal Health Record) is most prevailing initiative that gives secure access on patient record at anytime and anywhere. PHR should also incorporate decision support to help patients in self-management of their diseases. Available PHR system incorporates basic recommendations based on patient routine data. We have proposed decision support service called "Smart CDSS" that provides recommendations on PHR data for diabetic patients. Smart CDSS follows HL7 vMR (Virtual Medical Record) to help in integration with diverse application including PHR. PHR shares patient data with Smart CDSS through standard interfaces that pass through Adaptability Engine (AE). AE transforms the PHR CCR/CCD (Continuity of Care Record/Document) into standard HL7 vMR format. Smart CDSS produces recommendation on PHR datasets based on diabetic knowledge base represented in shareable HL7 Arden Syntax format. The Smart CDSS service is deployed on public cloud over MS Azure environment and PHR is maintaining on private cloud. The system has been evaluated for recommendation for 100 diabetic patients from Saint's Mary Hospital. The recommendations were compared with physicians' guidelines which complement the self-management of the patient.

Optimized Production of Poly(γ-Glutamic acid) By Bacillus sp. FBL-2 through Response Surface Methodology Using Central Composite Design

  • Min, Ju-Hee;Reddy, Lebaka Veeranjaneya;Charalampopoulos, Dimitris;Kim, Young-Min;Wee, Young-Jung
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.7
    • /
    • pp.1061-1070
    • /
    • 2019
  • In the present study, the optimization of poly(${\gamma}$-glutamic acid) (${\gamma}$-PGA) production by Bacillus sp. FBL-2 was studied using a statistical approach. One-factor-at-a-time method was used to investigate the effect of carbon sources and nitrogen sources on ${\gamma}$-PGA production and was utilized to select the most significant nutrients affecting the yield of ${\gamma}$-PGA. After identifying effective nutrients, response surface methodology with central composite design (CCD) was used to obtain a mathematical model to identify the optimum concentrations of the key nutrients (sucrose, $\text\tiny{L}$-glutamic acid, yeast extract, and citric acid) for improvement of ${\gamma}$-PGA production. The optimum amount of significant medium components appeared to be sucrose 51.73 g/l, $\text\tiny{L}$-glutamic acid 105.30 g/l, yeast extract 13.25 g/l, and citric acid 10.04 g/l. The optimized medium was validated experimentally, and ${\gamma}$-PGA production increased significantly from 3.59 g/l (0.33 g/l/h) to 44.04 g/l (3.67 g/l/h) when strain FBL-2 was cultivated under the optimal medium developed by the statistical approach, as compared to non-optimized medium.

Anti-wrinkle efficacy of isoquercitrin isolated from Nymphoides indica (어리연꽃에서 분리된 Isoquercitrin의 주름개선 효능 연구)

  • Yu, Jae-Myo;Kang, Yun-Hwan;Kim, Dong-Hee;Kim, You-Ah;Kim, A-Hyun;Park, Byoung-Jun;Park, Tae-Soon
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.4
    • /
    • pp.321-325
    • /
    • 2018
  • In this study, we evaluated the possibility of wrinkle-reducing functional cosmetic material of isoquercitrin (IQC) isolated from Nymphoides indica (NP) by measuring the efficacy of ROS inhibition, procollagen synthesis induction, and matrix metalloproteinase (MMP)-1 inhibition. As a result, ROS tended to be inhibited in a concentration dependent manner, and the procollagen protein synthesis rate was increased by 70% ($5{\mu}g/mL$) and the MMP-1 protein was decreased by 41% ($5{\mu}g/mL$) compared with the control. This was suggested the ability of IQC to induce the procollagen synthesis and to reduce the ROS and MMP-1 production. Therefore, it is considered that IQC isolated from NP has enough value to be a functional cosmetic material.

Qualitative and quantitative determination of oleanolic acid in a scalp tonic products by HPLC using response surface methodology for extraction optimization

  • Cai, Lin Xi;Cho, Chong Woon;Zhao, Yan;Kang, Jong Seong;Kim, Kyung Tae;Jung, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.48-55
    • /
    • 2019
  • The simple and effective analytical method for the quality control of a novel scalp tonic formulation has been developed and optimized in terms of HPLC conditions and sample preparation method, meanwhile, the optimization of preparation condition was using response surface methodology (RSM) based on central composite design (CCD). Oleanolic acid was selected as marker compound because of its bioactivities for alopecia therapy. The developed analytical method and extraction condition were successfully qualified. Coefficient of determination ($r^2$) for the calibration was 0.9997 with a line passing through the origin point in the range of 0.1-100 mg/mL. The limit of detection (LOD) and the limit of quantitation (LOQ) were 17.5 ng/mL and 55.0 ng/mL, respectively. The intra-day and inter-day precision of the method were 0.5-1.4 % and 0.7-1.8 % in relative standard deviation, respectively, while those accuracy were 99.5-100.9 % and 100.0-102.2 %, respectively. The repeatability of oleanolic acid in samples ranged of 0.3-1.9 % based on peak area and 0.3-0.7 % for retention time. Recoveries from samples were 95.0-99.4 % with lower than 1.8 % in relative standard deviation. Overall, the developed analytical method will be used for quality control of this commercial scalp tonic products successfully.

Analysis of Performance of Multi-functioned frictional force measuring instrument using adaptive smoothing (적응화 평활화법을 이용한 다기능 마찰력 측정기의 성능 분석)

  • Kim, Tae-Soo;Kim, Gwang-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.113-119
    • /
    • 2019
  • We have developed the multi-functioned friction measuring instrument for the previous research. In here, we improved the performance of friction measuring instrument by applying the adaptive smoothing method and analyzed the friction of plate and monitoring function of friction surface through scratch tests. We substituted lubricant steel plate to lubricant oil used for reducing the friction when fabricating steel plate because lubricant oil was regarded as one of the major causes for the environmental pollution. In particular, the functions of various plate such as galvannealed steel sheets were analyzed because friction coefficient could be changed depending on the type of organic/inorganic plate or state of coating layer. Therefore, we demonstrated that adaptive smoothing method could enhance the accuracy of measuring instrument which eliminate the noise. As a result of using the method, it showed the reduction rate 0.0417% for the friction coefficient 0.16.

Development of weight prediction 2D image technology using the surface shape characteristics of strawberry cultivars

  • Yoo, Hyeonchae;Lim, Jongguk;Kim, Giyoung;Kim, Moon Sung;Kang, Jungsook;Seo, Youngwook;Lee, Ah-yeong;Cho, Byoung-Kwan;Hong, Soon-Jung;Mo, Changyeun
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.753-767
    • /
    • 2020
  • The commercial value of strawberries is affected by various factors such as their shape, size and color. Among them, size determined by weight is one of the main factors determining the quality grade of strawberries. In this study, image technology was developed to predict the weight of strawberries using the shape characteristics of strawberry cultivars. For realtime weight measurements of strawberries in transport, an image measurement system was developed for weight prediction with a charge coupled device (CCD) color camera and a conveyor belt. A strawberry weight prediction algorithm was developed for three cultivars, Maehyang, Sulhyang, and Ssanta, using the number of pixels in the pulp portion that measured the strawberry weight. The discrimination accuracy (R2) of the weight prediction models of the Maeyang, Sulhyang and Santa cultivars was 0.9531, 0.951 and 0.9432, respectively. The discriminative accuracy (R2) and measurement error (RMSE) of the integrated weight prediction model of the three cultivars were 0.958 and 1.454 g, respectively. These results show that the 2D imaging technology considering the shape characteristics of strawberries has the potential to predict the weight of strawberries.