• Title/Summary/Keyword: cave water

Search Result 80, Processing Time 0.027 seconds

A Case Study on the Environmental Pollution in Caves (개방동굴의 환경오염 사례연구)

  • Shin, Dong-Won;Jung, Kyu-Whan;Cho, Yong-Ho
    • Journal of the Speleological Society of Korea
    • /
    • no.87
    • /
    • pp.18-22
    • /
    • 2008
  • A cave starts to be destructed and damaged as soon as it's open to the public. Due to many convenience facilities for tour visitors, it's gradually polluted. For example, lamplight causes green and black mold while temperature rise caused by many tourists and lamplight brings vatting and exfoliation. In addition, visitors'reckless behavior have caused water pollution and destructed cave creatures' habitat.

A Study on the Performance of Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil of the Machine Tool (공작기계 절삭유 냉각용 낮은 핀관의 열전달 성능에 관한 연구)

  • 조동현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.125-133
    • /
    • 1998
  • Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64mm height respectively are tested. A plain tube having same diameter as the finned tubes is also tested for comparison. In case of condensation CFC-11 condensates at saturation state of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube. The tube having fin density of 1299fpm and 30grooves has the best condensation overall heat transfer coefficient. However, as far as boiling heat transfer coefficient concerns, fin tubes with cave show higher value than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

The Petrographic Investigation of Soda Straws in Baeg-nyong Cave, Pyeongchang-gun, Gangwon-do, South Korea (강원도 평창군 백룡동굴에서 산출되는 종유관의 기재학적 연구)

  • Cho, Jae-nam;Jo, Kyoung-nam
    • Journal of the Korean earth science society
    • /
    • v.38 no.1
    • /
    • pp.64-79
    • /
    • 2017
  • We have reported the petrographic properties on the soda straw primarily based on the field measurements and discussed the causes of their traits. 156 soda straws in district B of the Baeg-nyong Cave nominated with the natural monument No. 260 have been investigated to estimate physical, sedimentological and textural characteristics. The soda straws have an average length of 3.05 cm with a standard deviation of 1.7 cm and a mean diameter of 6.0 mm. This result shows that the average diameter of the soda straws measured in this study is thicker than previous reports by 20%. Although the drip rates of cave water from 85.3% of all the soda straws are exceedingly lower than 1 drop per 10 minutes, almost all soda straws have a dripping water. We firstly report growth lamina in the Korean soda straw from 85.3% of all samples, and this textural dominance indicates that the growth lamina are one of the common features of the soda straws at least in the study area. Secondary precipitations inside the soda straw were identified from 68.6%. Notably, the strong inverse correlation between growth lamina and secondary precipitates was represented from 70.5% of all samples. This finding might be explained by the seasonality of cave drip water supplied into the soda straws or the increased opacity caused by secondary precipitates. Based on petrograhic characteristics, the soda straws in the study area can be classified into normal and erratic types. Hopefully our results on the soda straws in Baeg-nyong Cave would provide a basis for the descriptions of soda straws from other caves and paleoclimatic applications.

New 3D failure analysis of water-filled karst cave beneath deep tunnel

  • Zhang, R.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • In this study, both 2D and 3D failure shapes of rock mass above the water-filled cavity are put forward when the surrounding rock mass cannot bear the pressure caused by the water-filled cavity. Based on the analytical expressions derived by kinematic approach, the profiles of active and passive failure patterns are plotted. The sensitivity analysis is conducted to explore the influences of different rock parameters on the failure profiles. During the excavation of the deep tunnels above the karst cavity, the water table always changes because of progressive failure of cavity roof. Therefore, it is meaningful to discuss the effects of varying water level on the failure patterns of horizontal rock layers. The changing laws of the scope of the failure pattern obtained in this work show good consistency with the fact, which could be used to provide a guide in engineering.

Methodology to Quantify Rock Behavior in Shallow Rock Tunnels by Analytic Hierarchy Process and Rock Engineering Systems (계층 분석적 의사결정과 암반 공학 시스템에 의한 저심도 암반터널에서의 암반거동 유형 정량화 방법론)

  • Yoo, Young-Il;Kim, Man-Kwang;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.465-479
    • /
    • 2008
  • For the quantitative identification of rock behavior in shallow tunnels, we recommend using the rock behavior index (RBI) by the analytic hierarchy process (AHP) and the Rock Engineering Systems (RES). AHP and RES can aid engineers in effectively determining complex and un-structured rock behavior utilizing a structured pair-wise comparison matrix and an interaction matrix, respectively. Rock behavior types are categorized as rock fall, cave-in, and plastic deformation. Seven parameters influencing rock behavior for shallow depth rock tunnel are determined: uniaxial compressive strength, rock quality designation (RQD), joint surface condition, stress, pound water, earthquake, and tunnel span. They are classified into rock mass intrinsic, rock mass extrinsic, and design parameters. An advantage of this procedure is its ability to obtain each parameter's weight. We applied the proposed method to the basic design of Seoul Metro Line O and quantified the rock behavior into RBI on rock fall, cave-in, and plastic deformation. The study results demonstrate that AHP and RES can give engineers quantitative information on rock behavior.

Pro-environmental Maintenance and Management of Tour Cave : The Currents, Problems and Alternatives in Korea (관광동굴의 환경친화적 관리 방안에 관한 연구)

  • 유영준;이경호
    • Journal of the Speleological Society of Korea
    • /
    • v.59
    • /
    • pp.21-36
    • /
    • 1999
  • Most scholars calssify caves into natural resource, but caves possess values of natural and human resource, mix up the features of natural resources and human resources. Now, caves are distributed 260 in Korea. Seongryu Cave is showed in 1967 for the first time, till 1997 12 caves is opened to tourist. But since 1996 the 12 show caves of all is not launched the safety and environment-protection check-up adduced reason for IMF. Then caves must maintain environment of the normal temperature, humidity and dark. But the environment of caves are destroyed by tourism development. Thus to maintain environment of caves, it used to consider the counterplan as follows in restraint of the environmental change. Firstly, in case of development work to open caves, it must keep up with the prototype. Secondly, it must establish a freight depositary to prevent the influence of the caves's stain and damage due to tourist's objects. Thirdly, to maintain the normal temperature and humidity, it must install artificial poultice equipment of the inner parts of caves. Fourthly, in order to prevent the occurrence of $CO_2$, it must assessment of the optimum number of the greatest stayer. Fifthly, the control of closure for a given period of time is useful of the restoration to the cave's original state. Sixthly, by means of make narrow entrance, it should not influence the outer's air on the inner parts on caves. Seventhly, to keep the temperature of the inner part of caves, the lightening should be maintained moderately considering the convenience of a tour. Eightly, when water-proof cables for the lightening bulbs are connected each other, silicon tape is suitable and circuit breakers should be installed at the diverging points of the cables. Ninthly, the direction and angle of the lightening must be changed periodically to prevent green-pollution at the lightening spot. Lastly, when facilities and arrangements are equipped, corrosive materials should be excluded if circumstances allow.

  • PDF

A Geomorphological Study on the Distribution Areas of Freezing during Summer Season in Korea (한국의 하계 동결현상 분포지에 관한 지형학적 연구)

  • Jeon, Young-Gweon
    • Journal of the Korean association of regional geographers
    • /
    • v.7 no.1
    • /
    • pp.97-106
    • /
    • 2001
  • There are a few interesting areas which show freezing during summer season in Korea, three of them are especially important. They are located at Milyang(Gyungnam province), Uisung and Chungsong(Gyungbook province). They are named Eoleumgol(ice-valley) or Binghyul(ice-cave). The purpose of this study is to clarify geomorphological and geological characteristics about the distribution areas of freezing during summer season in Korea in relation to previous works, which have been studied in hydrological or micro-climatological viewpoints. The main results are summarized as follows. 1) The main geomorphological and geological characteristics in the distribution areas of freezing during summer season (1) Thick debris accumulated slope within deep valley (2) North facing slope (3) The component debris of volcanic rock such as andesite or rhyolite 2) The ice-cave as a system that give rise to freezing phenomenon in summer season is closely related to talus slope. The ice-cave has thick accumulated debris and lots of vacant spaces within the rock deposits, some of vacant spaces are very big and connected with underground water system. 3) A partly freezing within underground water system is required freezing phenomenon in summer season. Judging from this point of view, two ideas are suggested; one is the evaporation theory, another is that the frozen condition in winter remains untill late summer.

  • PDF

Regional differences in winter activity of hibernating greater horseshoe bats (Rhinolophus ferrumequinum) from Korea

  • Kim, Sun-Sook;Choi, Yu-Seong;Yoo, Jeong-Chil
    • Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Background: Hibernating bats exhibit ubiquitous winter activity in temperate zones, but there is considerable between- and within-species variety in their intensity and purpose. Bats may fly during winter for sustenance or travel to other hibernacula. This study compared inter-regional variation in the winter activity of the greater horseshoe bat (Rhinolophus ferrumequinum). We predicted that weather and hibernacula-environmental conditions would influence winter activity patterns. Results: Winter activity patterns differed between regions. In the Anseong area, we confirmed movement inside the hibernaculum, but in Hampyeong, we observed movement both inside and between hibernacula. The two regions differ by $4^{\circ}C$ in average winter temperatures. Anseong experiences 22 days during which average daily temperatures exceeded $5^{\circ}C$, whereas Hampyeong experienced 50 such days. During the hibernating period, bat body weight decreased by approximately 17-20% in both regions. Conclusions: Ambient temperatures and winter-roost environments appear to be behind regional differences in hibernating bat activity. As winter temperatures in Korea do not favor insect activity, feeding probability is low for bats. However, bats may need to access water. At Anseong, underground water flows inside the hibernaculum when the reservoir outside is frozen. At Hampyeong, the hibernaculum does not contain a water source, but the reservoir outside does not freeze during winter. In conclusion, water-source location is the most likely explanation for regional variation in the winter activity of hibernating bats.

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • 이종선
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.68-78
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • Jo, Dong Hyeon;Lee, Jong Seon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.65-65
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32℃ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.