• Title/Summary/Keyword: causes of fire

Search Result 516, Processing Time 0.026 seconds

A Study on the Possibility of Ignition by Disposable Lighter (사례를 통한 화재사(火災死)의 이해)

  • Jae, J.J.;Lee, C.W.;Keon, H.S.;Son, J.B.;Lee, J.I.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.59-75
    • /
    • 2007
  • The causes of the fire casualties were the heat burns, contacted by flame, before the period of industrialization. According to the economic has been developed drastically since 1990, residing space has been become bigger and sophistication and interior finishing materials have been diversified. Therefore, the suffocation casualties, caused by inspiration of toxic combustion gases, have been more increased than the flame casualties in recently. Also, the arson casualties have been increasing with the increasing of insurance crime to take the Insurance money. According to National Emergency Management Agency announcement, 31,778 fires was occurred nationwide in 2006 and the total casualties were 2,180 occurred. 446 persons were died among them. Because the exact investigation of fire, occurred the death, is very especially important that civil and criminal cases will be happened. Therefore, we studied about the cause of fire, the place of origin, and the group of casualties age on the axies of fires, which were occurred recently. And the identification method of fire casualties, the human behavior characteristic, the flame casualties and the suffocation casualties at fire scene.

  • PDF

Fire-countermeasures of Majority-used Buildings -Centering around Busan Metropolitan City- (다중이용업소의 소방안전관리방안 -부산광역시(사상구, 사하구, 북구)를 중심으로-)

  • Lee, Soon-Goo;Kong, Ha-Sung;Han, Sang-Yong
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.54-60
    • /
    • 2008
  • The occurrence of fires in heavily populated multiplex buildings is a serious concern. It causes a great threat to many people and a serious social problem. Whenever this kind of fire happens, the authorities are busy preparing partial countermeasures to control the crisis situations. Luckily, the government has enforced a special law regarding safety supervision of majority-used buildings to prepare the basic countermeasures for the buildings' safety. Recently, the multiplex buildings which have multi type compounds have increased in size by getting bigger and bigger. As there are many people who would need to escape and the complicated structures like mazes in buildings of this type, it is not only difficult to prevent a fire but also easy to cause a large loss of lives. For a better fire safety supervision of the buildings, there needs to be passers and owners' good sense of safety, fire proof of the buildings and education of the fire authorities.

Effects of Task Stress on the Job Satisfaction of Fire Protection Management Workers (소방시설관리업 종사자의 직무스트레스가 직무만족에 미치는 영향)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.130-139
    • /
    • 2019
  • This study identified the level of task stress experienced by fire protection system management workers and analyzed the effects of task stress on job satisfaction and proposed future response. First, task stress according to background cause showed differences in relation to age, position, monthly salary, total career, license, and task, but there was no difference in relation to academic background. Second, of the sub-parameters of stress, physical environment, task demand, organizational system, lack of reward, and workplace culture have negative effects on job satisfaction as stress increases, while interpersonal relation conflict and job insecurity do not have any effect. In the future, it will be necessary to investigate the empirical causes of work overload and to study organization-level stress relief measures.

A Study on the Fire Case Analysis of Air Conditioner and Preventive Measures (에어컨 화재사례 분석 및 예방대책에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Bang, Sun-Bae;Chung, Young-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.40-45
    • /
    • 2013
  • In recent years, many electrical fires have occurred due to complex causes. Therefore, products are required to make with scientific design considering electrical, thermal, mechanical and environmental influences. Disasters can cause losses of life and property with fall in confidence of countries and companies. And demands for safe product have been increased by reason of recent deregulation followed by limitless competition. It is necessary to design safe product in order to improve corporate image and strengthen international competitive power. This paper addresses electrical fire case of air conditioner. The use of air conditioner have recently increased as a result of global warming. The aim of this study is to provide safety design and fire prevention measures of air conditioner through cause analysis and reappearance experiments.

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

Construction of Case-based System for the Cause Diagnosis of an Electrical Fires (전기화재 원인진단을 위한 사례기반 시스템 구축)

  • Lee, Jong-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.42-47
    • /
    • 2007
  • This paper presents the development of a case-based system for an electrical fire cause diagnosis system using the entity relation database. The relation database which provides a very simple but powerful way of representing data is widely used. The system focused on database construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. In order to store and access to the information concerned with electrical fires, the key index items which identify electrical fires uniquely are derived out. The case-based system consists of a case which contains information from the past fires. The case-based system could present the cause of a newly occurred fire to be diagnosed by searching the case-based database for reasonable matching. The case-based system has not only searching functions with multiple attributes by using the collected various information(such as fire evidence, structure, and weather of a fire scene) but also more improved diagnosis functions which can be easily used for the electrical fire cause diagnosis system.

Analysis of Vertical Combustion and Carbonization Patterns of Floor Materials When Using a Needle Flame (니들 플레임에 의한 바닥재의 수직 연소 및 탄화 패턴의 해석에 관한 연구)

  • Park, Min-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.101-106
    • /
    • 2020
  • This study analyzed flame growth characteristics and carbonization patterns when floor materials were burned vertically using a needle flame produced for this study. It was found that PVC flooring was fire retardant and the area under direct flame contracted inward. Vertical combustion causes solidification in the form of a lump at the bottom and also generates soot in a pattern that progresses upwards. This study found that laminated flooring exhibited no fire retarding characteristics and that the laminated layer of its upper surface was destroyed by fire, causing irregular delamination. The carbonization ranges at the left and right sides were determined to be symmetrical. A vertical combustion test of a sample carpet showed that it exhibited no fire-retarding characteristics. It was observed that if heat accumulated in the carpet, the flame formed an ascending air current, and that when flammable materials were present around the flame, they further accelerated the diffusion of the flame. The carbonization pattern at the carpet surface exposed to direct flame revealed that the carpet surface had melted and had flown downwards and that many tiny holes formed on it.

Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution (전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.