• Title/Summary/Keyword: causes of fire

Search Result 516, Processing Time 0.028 seconds

Analysis on the Structure Variation of IV Transformed by the Overload (과부하에 의해 변형된 비닐절연전선의 구조변화 분석)

  • 최충석;김형래;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.398-401
    • /
    • 2002
  • When the current flows over the allowable current due to the overload, it causes electric disaster such as an electrical fire and an electric shock by short current or leakage of electricity because the covering is deteriorated according to the heating action. In this paper, for the wire(IV 1.6mm) used as interior wiring, we analyzed a variation of the surroundings temperature, the form and the structure of a covering, and the crystal structure of a conductor. In the result of this experiment, the surroundings temperature at the allowable current of 300% rose to about 47$^{\circ}C$, and it rose up to the maximum allowable temperature of the wire at 400%. Consequently, it was broken within one minute at 500%. In the analysis of a metallograph, the conductor broken by the over current showed the dendrite. These analyses result will be applied to judging the electrical fire.

  • PDF

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.

Physical Response of Human Body Wearing Self Contained Breathing Apparatus (소방용 공기호흡기 착용에 따른 신체반응)

  • Bang, Chang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.8-12
    • /
    • 2012
  • The aim of study intends to investigate physical response of human body wearing Self Contained Breathing Apparatus and to provide the base data for the safety of firefighter. The results of the study are as follows. when wearing SCBA, the mean skin temperature (7 %), heart rate (28 %), rate of perceived exertion (65.4 %), metabolic equivalents (70.7 %) were significantly higher (p<.05), respiratory rate was not statistically significant. It is concluded that wearing SCBA causes significant stress to the physical systems.

Arc Fault Circuit Interrupter Design for Electrical Fire Protection (전기화재 방지를 위한 아크고장전류 차단기 설계)

  • Ban, Gi-Jong;Kim, Lark-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.220-225
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc fault circuit interrupter does not have the arc current interrupt function. Hence, Arc current controller is designed for the interruption of arc fault current which has the modified arc characteristics.

Occurrence quantity comparison of the toxic gases of the railway car's gangway materials using a Smoke Density-Chamber (철도차량용 통로연결막 재료별 독성성분의 발생량 비교)

  • Lee, Eun-Kyoung;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1533-1539
    • /
    • 2007
  • It is mainly due to the toxic gases, produced from the material combustion, threatens human body in case of urban railway car like subway which passes through underground tunnel. In the field of railway industry, fire accidents was not frequent but occurs in each country and, the causes was investigated. The advanced country established the test standard (e.g., BS, EN) to measure the toxic gases quantitatively and, have applied to enhance the fire safety of railway car. We must also follow the procedures to use gangway material for railway car as stated the Safety regulation for the urban railway car. In this study, various gangway materials(silicon, synthtic rubber, soaltapulin) are used to investigate element of toxic gases when the fire occurs. The amount of toxic gases measured from the ISO 5659 chamber using cone heater was measured and compared the results for each materials.

  • PDF

An Electrical fire Diagnosis System Using the Mixed Approach of the Case-Based Reasoning with the Knowledge-Based Reasoning (지식기반 추론과 사례기반 추론의 혼합 적용 기법을 이용한 전기화재 원인진단 시스템)

  • 권동명;김두현;김상철;김상렬
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.223-228
    • /
    • 1999
  • This paper presents an electrical fire diagnosis system using intellectual reasoning which is the mixed approach of the case-based reasoning with the knowledge-based reasoning A prototype system is implemented using Delphi, one of the program development tools under windows environment, for making an application program for database. And database is builded using Paradox. The results of applying the system to some imaginary fire cases to verify its capability and validity show that the causes of fires is successfully diagnosed, so the proposed system proves to be reasonable.

  • PDF

Analysis on the effect of the forest fire and rainfall on landslide in Gangwon area (강원지역 산사태발생지의 산불발생이력과 강우특성에 관한 분석)

  • Jun, Kyoung-Jea;Lee, Seung-Woo;Yune, Chan-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1020-1025
    • /
    • 2009
  • Recently, unusual change of weather occurred in world wide region causes localized heavy rainfall and consequently disasters like landslide and debris flow in steep slope area. And the main factors of these disasters are rainfall and forest fire. To verify the existing landslide prediction and warning system, information about landslide and rainfall were collected for a data base system and analysed.

  • PDF

A Study on the Improvement of Safety Management by Analyzing the Current Status and Response System of Forest Fire Accidents (산불사고 현황과 대응체계 분석을 통한 안전관리 개선방안 연구)

  • Jeong, Kyung-ok;Kim, Dae-jin
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.457-469
    • /
    • 2022
  • Purpose: The purpose of this study is to present the direction of improvement of safety management by reviewing the current status of forest fire accidents that are becoming larger throughout the year and the problems of the response system. Method: Domestic and foreign literature survey and statistics of recent forest fire accidents by Statistics Korea investigated and analyzed the cause, number of damage, and suggested ways to improve forest fire safety management through domestic and foreign forest fire response systems. Result: Through the analysis of the causes of recent wildfires and overseas response cases, measures to improve the safety management of wildfires in terms of hardware, software, and humanware were derived. Conclusion: The plan to improve forest fire safety management was classified into three main categories and presented, and it should be embodied through further related research.

Performance Analysis and Improvement of National Fire Safety Code elements of Sprinkler System (스프링클러설비의 화재안전기준 요소의 성능분석 및 개선방안)

  • Oh, Taekhum;Lee, Jungil
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.413-422
    • /
    • 2013
  • This study evaluated the fire safety code elements through analyze the loss of life when the fire occurred in the facility sprinklers installed evaluated. And through comparison with national fire safety code elements and standards of NFPA 13 in the United States, Was looking for ways to improve for Life and property damage. In the United States, in some cases, if you do not install the sprinkler are installed as per the fire death rate compared to 83 % lower. By contrast, If the domestic rate of 280 % fatalities were 3.37 times than the United States. This lack of fire performance were analyzed uniform occupancy classification, the amount of source of water supply, live not consider the density according to the standard number and the horizontal distance that causes the installation of sprinkler facilities were analyzed.

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.