• Title/Summary/Keyword: caudal

Search Result 847, Processing Time 0.023 seconds

Quantification of Brain Images Using Korean Standard Templates and Structural and Cytoarchitectonic Probabilistic Maps (한국인 뇌 표준판과 해부학적 및 세포구축학적 확률뇌지도를 이용한 뇌영상 정량화)

  • Lee, Jae-Sung;Lee, Dong-Soo;Kim, Yu-Kyeong;Kim, Jin-Su;Lee, Jong-Min;Koo, Bang-Bon;Kim, Jae-Jin;Kwon, Jun-Soo;Yoo, Tae-Woo;Chang, Ki-Hyun;Kim, Sun-I.;Kang, Hye-Jin;Kang, Eun-Joo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.241-252
    • /
    • 2004
  • Purpose: Population based structural and functional maps of the brain provide effective tools for the analysis and interpretation of complex and individually variable brain data. Brain MRI and PET standard templates and statistical probabilistic maps based on image data of Korean normal volunteers have been developed and probabilistic maps based on cytoarchitectonic data have been introduced. A quantification method using these data was developed for the objective assessment of regional intensity in the brain images. Materials and Methods: Age, gender and ethnic specific anatomical and functional brain templates based on MR and PET images of Korean normal volunteers were developed. Korean structural probabilistic maps for 89 brain regions and cytoarchitectonic probabilistic maps for 13 Brodmann areas were transformed onto the standard templates. Brain FDG PET and SPGR MR images of normal volunteers were spatially normalized onto the template of each modality and gender. Regional uptake of radiotracers in PET and gray matter concentration in MR images were then quantified by averaging (or summing) regional intensities weighted using the probabilistic maps of brain regions. Regionally specific effects of aging on glucose metabolism in cingulate cortex were also examined. Results: Quantification program could generate quantification results for single spatially normalized images per 20 seconds. Glucose metabolism change in cingulate gyrus was regionally specific: ratios of glucose metabolism in the rostral anterior cingulate vs. posterior cingulate and the caudal anterior cingulate vs. posterior cingulate were significantly decreased as the age increased. 'Rostral anterior'/'posterior' was decreased by 3.1% per decade of age ($P<10^{-11}$, r=0.81) and 'caudal anterior'/'posterior' was decreased by 1.7% ($P<10^{-8}$, r=0.72). Conclusion: Ethnic specific standard templates and probabilistic maps and quantification program developed in this study will be useful for the analysis of brain image of Korean people since the difference in shape of the hemispheres and the sulcal pattern of brain relative to age, gender, races, and diseases cannot be fully overcome by the nonlinear spatial normalization techniques.

A Taxonomic Study of the Genera Acanthogobius and Synechogobius (Pisces : Gobiidae) from Korea (한국산(韓國産) 문절망둑 속(屬)과 풀망둑속(屬) 어류(魚類)의 분류학적(分類學的) 연구(硏究))

  • Lee, Yong-Joo
    • Korean Journal of Ichthyology
    • /
    • v.4 no.2
    • /
    • pp.1-25
    • /
    • 1992
  • Taxonomic study of the five species (Acanthogobius elongata, A. flavimanus, A. lactipes, A. luridus and Synechogobius) from Korea was carried out based on morphometric, cephalic sensory canal and ecological characters. Taxonomic revision and classificational keys are provided. Synechogobius hasta is easily distinguished from four species of the genus Acanthogobius in eleven characters, i. e., the number of dorsal and anal fin rays, the transverse scales, the vertebral numbers, the formula of interneural spine of the first dorsal fin, the number of interhemal spine anterior to the first hemal spine, the number of epipleural and pleurals, the ratio of caudal peduncle length, the ratio of caudal peduncle depth and the regular variations in the ratio of body parts with the body length. In the genus Acanthobobius, A. elongata is distinguished from other 3 congeneric species in the ratio of body parts and the oculoscapular sensory canal. Moreover, A. flavimanus differs from other 3 congeneric species in the lateral scales, the transverse scales, the number of predorsal scales, the vertebral number, the number of epipleural and pleurals. Sensory papillae rows of S. hasta is not similar that of the genus Acanthogobius in having a singular sensroy papillae rows. A. elongata has no oculoscapular sensory canal D and A. flavimanus has transverse sensory papillae in cheek, and these are one of the unique characters distinguished form other congeneric species. In the spawning period inferred from gonadosomatic index, A. elongata varied from late March to late June ; A. flavimanus, January to April ; A. lactipes, May to September ; A. luridus, early May to early July and S. hasta, early March to early May.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors (간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계)

  • Jeon, Mi-Jin;Lee, Chang-Geol;Lee, Ik-Jae;Choi, Won-Hoon;Choi, Yun-Sun;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Suk;Cho, Yoon-Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.75-83
    • /
    • 2010
  • Purpose: It aims to evaluate the location change and tendency of hepatic and intrahepatic tumors according to gastric volume and change of location. Materials and Methods: It studied 9 patients with hepatic tumors who visited Gangnam Severance Hospital from March 2009 to April 2010 and who underwent CT or PET (Positron Emission Tomography) within 2 weeks before CT-simulation. The patients fasted for 6 hours before CT-simulation and drank 240~250 cc of water just before CT or PET for image fusion. Those two types of images were fused to RTP (Radiation Treatment Planning, Pinnacle 8.0h) focusing on bone structure of individual patients. Results: They drank 240~260 cc of water but their stomach volume after drinking water varied from 259.3 cc to 495.4 cc. Even though individual differences existed in the change of stomach volume before and after drinking water, the volume was increased by 130 cc (174%) on average. The change in absolute distance between the centers of tumors ranged from 0.52 cm to 3.04 cm (1.52 cm on average); from 0.1 cm to 1.35 cm (0.44 cm on average) in cranial-caudal direction; from 0.05 cm to 2.75 cm (1.22 cm on average) in left-right direction; and from 0.05 cm to 1.85 cm (0.33 cm on average) in ventral-dorsal direction. Conclusion: It is hard to predict the movement of tumors by observing stomach movement, due to great individual differences; however, it was observed that the location of hepatic tumors was right-sided as the stomach was filled with water. Thus, it is recommended to maintain the fastened state to secure the accuracy of hepatic tumor treatment. If it cannot maintain the fastened state, it is recommended to measure stomach volumes and movement in the patient to consider the movement of hepatic tumors before radiation treatment.

  • PDF

Age Determination by Tooth Wear and Histological Analysis of Seasonal Variation of Breeding in the Lesser White-Toothed Shrew, Crocidura suaveolens (작은땃쥐 Crocidura suaveolens의 치아 마모에 의한 연령결정과 번식의 계절적 변이의 조직학적 분석)

  • Jeong, Soon-Jeong;Yoon, Myung-Hee;Kim, Sook-Hyang;Ham, Joo-Hyun;Lim, Do-Seon;Choi, Baik-Dong;Park, Jin-Ju;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.40 no.3
    • /
    • pp.125-132
    • /
    • 2010
  • Captured specimens of the lesser white-toothed shrew, Crocidura suaveolens were classified into three age classes by tooth wear and seasonal variations of reproductive organs were investigated. Molars of juveniles had not tooth wear and the height of the third molars were lower than the first and second molars, young adults had smooth tooth wear and the third molars reached to the first and second molars, and old adults had heavy tooth wear and the third molars also reached to the first and second molars. On the basis of histological examination, seasonal variation of breeding was confirmed that breeding season of adult males was from early February to early October, having a peak of the breeding in April and July, and non-breeding season was from in the middle of October to late January. Young and old adult males of the breeding season had large testes with enlarged seminiferous tubules filling with numerous germ cells and expanded caudal epididymides with a vast number of spermatozoa, Young and old adult males of the non-breeding season had the small testes with the extremely slender seminiferous tubules filling with only spermatogonia and the reduced caudal epididymides without spermatozoa. Males weighing more than 3.9 g in the body weight and 0.013 g in the testis and epididymis weight reached sexual maturation in breeding season, and the females weighing more than 3.8 g in body weight of the breeding season were pregnant condition having 5~6 litters or had the Graafian follicles and the corpus lutea in the ovary.

Effects of Bosaengtang Administration in Pregnant Rats and Fetuses (보생탕이 랫드의 모체와 태자에 미치는 영향에 대한 연구)

  • Kim, Chang-Seok;Lee, Sun-Dong;Kim, Pan-Gyi;Lee, Jang-Woo;Park, Hae-Mo
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.9 no.2
    • /
    • pp.59-75
    • /
    • 2005
  • The experiments were undertaken to evaluate the effects of Bosaengtang in pregnant rats and fetuses. Female Sprague-Dawley rats were orally administered with Bosaengtang at the dose of 5mg/kg/day for 20 days. Pregnant rats were sacrificed at the 20th day of gestation, and observed internal and reproductive organs. Fetuses were randomly selected and fixed in 95% ethanol. Fetuses were stained with alcian blue and alizarin red S, and observed skeletal malformations. The results obtained were as follows : Bosaengtang administered group showed higher maternal body weight than the control group, but both groups showed increase in weight. Bosaengtang administered group showed lower than the control group, and higher liver and kidney weight than the control group, but the differences were minimal. There were no significant changes between the control and treated group in blood chemistry values and hematological values but all the groups were within in normal ranges. There were no significant changes in the number of corpus luteum, implantation, live fetus and implantation rate, delivery rate, late resorption rate, sex ratio, but Bosaengtang administered group showed higher early resorption rate than control group. comparing the control and Bosaengtang group, neonatal body weight and the number of fetuses were increased in Bosaengtang group. The fetuses of dams treated with Oriental medicine didn't showed external malformation. Vertebral and sternal variations were observed in Bosaengtang group, but the differences were not apparent compared to the control group. The number of ribs, cervical, thoracic and lumbar vertebrae were normal. The number of sacral was similar and the number of caudal was increased. Fetuses showed significant difference in the number of caudal vertebrae. (P<0.01) From these results, we can carefully conclude that Bosaengtang showed beneficial effects on maternal body weight, early resorption rate, number of live fetus. There were no significant changes in organ weight, hematoscopy, reproduction organs. External malformation wasn't visible. Skeletal variations were showed in vertebrae and sternum but compared to the control group, these variations weren't much different.

  • PDF

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Generic Characters of Vertebrae and Pterygiophore of the Fishes of the Family Tetraodontidae (Teleostei: Tetraodontiformes) (참복과(복어목) 어류의 속별 척추골과 담기골 특징)

  • HAN Kyeong-Ho;KIM Yong Uk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.645-653
    • /
    • 1998
  • Twenty seven species of pufferfishes (family Tetraoaontidae) have been examined to find their generic characters based on vertebrae and pterygiophore characters of specimens collected in 20 localities along the coast of Korea from March, 1991 to March, 1994. It was divided by 3 groups based on vertebrae number as follow : the genera Lagocephalus, Pleurancanthus, Spheoides, Arothron, Chelonoeon and Canthigaster have 17$\~$19 vertebrae, genera Ephippion, Boesemanichthys and Feroxodon have 20 vertebrae, and genus Takifugu have 19$\~$25 vertebrae, The number of vertebrae ranged from 17 to 25 with the maximum of 25 in Takifugu obscurus. The modal number of vertebrae in Lagocephalus is 17 (L. lunaris), 18 (L. inermis), and 19 (L. gloveri, L. wheeleri, L. larigatus), with the lower number more specialized. Paired neural spines appear at number of the 1st$\~$5th vertebrae in Takifugu pardalis, Takifugu obscurus and at number of the 1 st$\~$4 th vertebrae in the other species and genera. All of the species of Lagocephalus and Pleurancanthus have dorsal and ventral pterygiophores processes, and flat-shaped epural, while none of the abdominal vertebrae processes complete haemal arches. The neural and haemal spines of the last few caudal vertebrae aye shorter in Pleurancanthus than in the other genera, associated with the depressed caudal peduncle. The genus Canthigaster is distinguished the first pterygiophores of the dorsal and ventral fins is always much larger than the others genera. Based on the haemal arches and spines of the abdominal vertebrae, genus Canthigaster has different characters from the other genera of the family Tetraodontidae.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF