• Title/Summary/Keyword: catalytic combustion sensor

Search Result 12, Processing Time 0.02 seconds

Catalytic combustion type hydrogen micro gas sensor using thin film heater and nano crystalline SnO2 (나노 결정 SnO2와 백금 박막히터를 이용한 접촉연소식 마이크로 가스센서의 감응특성 연구)

  • Han, Sang-Do;Hong, Dae-Ung;Han, Chi-Hwan;Chun, Il-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.178-182
    • /
    • 2008
  • Planar type micro catalytic combustible gas sensor was developed by using nano crystalline $SnO_2$ Pt thin film as micro heater was deposited by thermal evaporation method on the alumina substrate. The thickness of the Pt heater was around 160 nm. The sensor showed high reliability with prominent selectivity against various gases(Co, $C_3H_8,\;CH_4$) at low operating temperature($156^{\circ}C$). The sensor with nano crystalline $SnO_2$ showed higher sensitivity than that without nano crystalline $SnO_2$. This can be explained by more active adsorption and oxidation of hydrogen by nano crystalline $SnO_2$ particles. The present planar-type catalytic combustible hydrogen sensor with nano crystalline $SnO_2$ is a good candidate for detection of hydrogen leaks.

Gas Detecting Characteristics Using Catalytic Combustion Type Gas Sensor (접촉연소식 가스 센서를 이용한 감도특성)

  • Yoon, Hun-Ju;Ko, Keel-Young;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.773-777
    • /
    • 2002
  • In this study, we analyzed the LPG and LNG sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 0~85 percent at a temperature of $20[{\mu}m]$ and humidity of 45 percent at a temperature of $-10{\sim}40[^{\circ}C]$ the gas detecter sensors are to be subjected to operation for 210 days in an area that has been detemined to be equivalent to a typical residential atmosphere with an air velocity of 50 [cm/sec]. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a separate source of supply direct applied voltage 2.1[V], 2.2[V], 2.3[V]. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the LPG characteristic graph and methane characteristics graph by a relative humidity of 0 ~ 85 [%] at a temperature range of $-10{\sim}40[^{\circ}C]$ show a similar linear pattern on the whore.

  • PDF

Catalytic combustion type hydrogen gas sensor using TiO2 and UV LED (TiO2 광촉매와 UV LED를 이용한 접촉연소식 수소센서)

  • Hong, Dae-Ung;Han, Chi-Hwan;Han, Sang-Do;Gwak, Ji-Hye;Lee, Sang-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.7-10
    • /
    • 2007
  • A thick film catalytic gas sensors which can be operated at $142^{\circ}C$ in presence of ultra violet-light emitting diode has been developed to measure hydrogen concentration in 0-5 % range. The sensing material as a combustion catalyst consists of $TiO_{2}$ (5 wt%) and Pd/Pt (20 wt%) supported on $Al_{2}O_{3}$ powder and the reference material to compensate the heat capacity of it in a bridge circuit was an catalyst free $Al_{2}O_{3}$ powder. Platinum heater and sensor materials were formed on the alumina plate by screen printing method and heat treatment. The effect of UV radiation in the presence of photo catalyst $TiO_{2}$ on the sensor sensitivity, response and recovery time has been investigated. The reduction of operating temperature from $192^{\circ}C$ to $142^{\circ}C$ for hydrogen gas sensing property in presence of UV radiation is attributed to the hydroxy radical and superoxide which was formed at the surface of $TiO_{2}$ under UV radiation.

The $CH_4$and $C_4$$H_{10}$ Sensitivity Measurement and Voltage Variation Using Catalytic Combustion Type Gas Sensor (접촉연소식 센서를 이용한 $CH_4$$C_4$$H_{10}$ 감도 측정 및 전압변화)

  • 윤헌주;신종열;홍진웅
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.44-48
    • /
    • 2001
  • In this study, we analyzed the $CH_4$and $C_4$$H_{10}$ sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. Gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 65 percent at a temperature of $20^{\circ}c$ and humidity of 85 percent at a temperature of $40^{\circ}c$. The gas detecter sensors are to be subjected to operation for 210 days in an area that has been determined to be equivalent to a typical residential atmosphere with an air velocity of 50 cm/sec. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a seperate source of supply direct applied voltage 2.1V, 2.2V, 2.3V. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the isobutane characteristic graph and methane characteristic graph by a relative humidity of 65% and 85% at a temperature($20^{\circ}c$, $40^{\circ}c$) show a similar linear pattern on the whore.

  • PDF

An Experimental Study on the Transient Response of Hydrogen Sensors Dependent on Gas Temperature and Humidity (가스의 온도 및 습도 변화에 따른 수소 센서 응답 특성에 대한 실험적 연구)

  • Kim, Young-Doo;Chung, Tae-Yong;Shin, Dong-Hoon;Nam, Jin-Hyun;Kim, Young-Gyu;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.5
    • /
    • pp.15-19
    • /
    • 2009
  • In this study, the transient responses of hydrogen sensor against abrupt hydrogen release was experimentally studied for three most common types of hydrogen sensors, i.e. the semiconductor type, electrochemical type, and catalytic combustion type. The experimental study was conducted using a 1% hydrogen - 99% nitrogen mixture gas as the standard gas, while the temperature and relative humidity (RH) of the mixture gas was varied from $25^{\circ}C$ to $50^{\circ}C$ and from 50% to 100%, respectively. The temperature of the mixture gas was found to influence the output signal levels of hydrogen sensors, especially the catalytic combustion type. However, the effect of RH on the sensor response was not noticeable in the present experimental study. Thus, the signal levels of hydrogen sensors, in case of catalytic gas sensor need to be calibrated dependent on gas temperature, when the accurate determination of hydrogen concentration is important.

  • PDF

Improved hydrogen sensing characteristics of flat type catalytic combustible hydrogen gas sensor of micro-structure (평판형 접촉연소식 마이크로 수소센서의 감지특성 향상)

  • Kim, Chan-Woo;Gwak, Ji-Hye;Chun, Il-Su;Han, Sang-Do;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.202-206
    • /
    • 2009
  • Flat type catalytic combustible hydrogen sensors were fabricated using platinum micro-heaters and sensing material pastes. The platinum micro-heater was formed on an alumina substrate by sputtering method. The paste for the sensing materials was prepared using ${\gamma}-Al_2O_3$ 30 wt%, $SnO_2$ 35 wt%, and Pd/Pt 30 wt% and coated on the platinum micro-heater. The sensing performances were tested for the prepared sensors with different substrate sizes. The micro catalytic combustible hydrogen sensors showed quick response time, high reliability, and good selectivity against various gases(CO, $C_3H_8,\;CH_4$) at low operating temperature of $156^{\circ}\C$.

Electrical modelling for thermal behavior and gas response of combustible catalytic sensor (접촉연소식 센서의 열 특성 및 가스반응의 모델링)

  • Lee, Sang-Mun;Song, Kap-Duk;Joo, Byung-Su;Lee, Yun-Su;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.34-39
    • /
    • 2006
  • This study provides the electrical model of combustible catalytic gas sensor. Physical characteristics such as thermal behavior, resistance change were included in this model. The finite element method analysis for sensor device structure showed that the thermal behavior of sensor is expressed in a simple electrical equivalent circuit that consists of a resistor, a capacitor and a current source. This thermal equivalent circuit interfaces with real electrical circuit using two parts. One is 'power to heat' converter. The other is temperature dependent variable resistor. These parts realized with the analog behavior devices of the SPICE library. The gas response tendency was represented from the mass transferring limitation theory and the combustion theory. In this model, Gas concentration that is expressed in voltage at the model, is converted to heat and is flowed to the thermal equivalent circuit. This model is tested in several circuit simulations. The resistance change of device, the delay time due to thermal capacity, the gas responses output voltage that are calculated from SPICE simulations correspond well to real results from measuring in electrical circuits. Also good simulation result can be produced in the more complicated circuit that includes amplifier, bios circiut, buffer part.

Hydrocarbon Gas-sensing Properties of Catalytic Combustion Type Gas Sensor (접촉연소식 가스센서의 탄화수소계 가스 감응 특성)

  • Lee, Dae-Sik;Lee, Sang-Mun;Nam, Ki-Hong;Han, Sang-Do;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.327-332
    • /
    • 1999
  • Catalytic combustion type gas sensors were fabricated by using noble metal(Pt and Pd) added ${\gamma}-Al_2O_3$ powder with specific surface area of $200\;m^2/g$. The fabricated sensor showed power consumption of 500 mW at the operating voltage of 1.75 V and high sensitivity of about 120 mV for butane, methane, or propane 100%LEL, respectively. The sensor properties also showed good linearity to hydrocarbon gas concentration variation, reproductivity and stability for relative humidity variation. And it showed high stability in butane ambient for 100 days.

  • PDF

Alcohol Detecting Characteristics of Catalytic Sensor (접촉연소식 센서의 알코올 검지 특성)

  • Kim, Jong-Won;Son, Young-Mok;Sim, Kyu-Sung;Park, Kee-Bae;Lee, Sang-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.32-39
    • /
    • 1994
  • Catalytic combustion type sensor was fabricated for alcohol detection, and its characteristics were tested. When the resistance of Pt coil for pellistor is 2.0 ohm, suggestible input power to bridge circuit was about 300 mW for methanol detection, and in the range from 350 mW to 400 mW for ethanol. Pellistors were prepared by means of impregnating Pt or Pd on the ${\gamma}$-alumina bead for sensing element, and transition metals such as $Co_{3}O_{4}$, $Fe_{2}O_{3}$ for compensating element.

  • PDF

Review on Sensor Technology to Detect Toxic Gases (독성가스 감지용 센서 기술 동향 리뷰)

  • Lee, Janghyeon;Lim, Si-Hyung
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.311-318
    • /
    • 2015
  • The excess use and generation of various toxic gases from many industrial complexes and plant facilities have increased the possibility of leakage or explosion accidents, which can cause fatal damage to human beings in the wide range of neighboring area. To prevent the exposure to the fatal toxic gases, it is very important to monitor the leakage of toxic gases using gas sensors in real time. Various types of gas sensors, which can be classified as semiconductor, electrochemical, optical, and catalytic combustion types according to the operating principles, have been developed. In this review, the operation principles of gas sensors are explained and the performance of those sensors is compared. The state-of-the-art gas sensor technologies developed by research institutes or companies are reviewed also.