• 제목/요약/키워드: cast-in-concrete

검색결과 499건 처리시간 0.022초

인공어초용 재생골재 콘크리트의 최적 배합설계 모델 (Optimal Mix Design Model of Recycled Aggregate Concrete for Artificial fishing Reefs)

  • 홍종현;김문훈;우광성;고성현
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.53-62
    • /
    • 2004
  • The Purpose of this study is to recycle the waste concrete, which is generated in huge quantities, from construction works. in order to achieve this goal, it is important to determine the compressive strength, workability, slump, and ultrasonic velocity of recycled aggregate concrete. Thus, several experiment parameters are considered, such as water-cement ratios, sand percentage, and fine aggregate composition ratios, in order to apply the recycled aggregate concrete to pre-cast artificial fishing reefs. From the results, it has been shown that the proper mix designs for reef concrete are W/C=45%, S/a=50%, SR50:SN50 in recycled sand and natural sand mix combination case, W/C=45%, S/a=50%, SC50:SN50 in crushed sand and natural sand mix combination case, W/C=45%, S/a=50%, SR50:SC50 in recycled sand and crushd sand mix combination case. Also, this study shows that the shape and surface roughness of fine aggregate particles have an effect on the strength, slump, ultrasonic velocity of tested concrete, and the compressive strength ratios of 7days' and 90days' curing ages of recycled aggregate concrete are about 70% and 110% of 28days' curing age.

Design for shear strength of concrete beams longitudinally reinforced with GFRP bars

  • Thomas, Job;Ramadassa, S.
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.41-55
    • /
    • 2015
  • In this paper, a model for the evaluation of shear strength of fibre reinforced polymer (FRP)-reinforced concrete beams is given. The survey of literature indicates that the FRP reinforced beams tested with shear span to depth ratio less than or equal to 1.0 is limited. In this study, eight concrete beams reinforced with GFRP rebars without stirrups are cast and tested over shear span to depth ratio of 0.5 and 1.75. The concrete compressive strength is varied from 40.6 to 65.3 MPa. The longitudinal reinforcement ratio is varied from 1.16 to 1.75. The experimental shear strength and load-deflection response of the beams are determined and reported in this paper. A model is proposed for the prediction of shear strength of beams reinforced with FRP bars. The proposed model accounts for compressive strength of concrete, modulus of FRP rebar, longitudinal reinforcement ratio, shear span to depth ratio and size effect of beams. The shear strength of FRP reinforced concrete beams predicted using the proposed model is found to be in better agreement with the corresponding test data when compared with the shear strength predicted using the eleven models published in the literature. Design example of FRP reinforced concrete beam is also given in the appendix.

Effect of fly ash and plastic waste on mechanical and durability properties of concrete

  • Paliwal, Gopal;Maru, Savita
    • Advances in concrete construction
    • /
    • 제5권6호
    • /
    • pp.575-586
    • /
    • 2017
  • The disposal of polythene waste and fly ash is causing serious threat to the environment. Aim of this study is to decrease environmental pollution by using polythene waste and fly ash in concrete. In this study, cement was partially replaced with 0%, 5%, 10%, 15% and 20% fly ash (by weight) and plastic waste was added in shredded form at 0.6% by weight of concrete. The specimens were prepared for the concrete mix of M25 grade and water to cementitious material ratio (w/c) was maintained as 0.45. Fresh concrete property like workability was examined during casting the specimens. Hardened properties were found out by carrying out the experimental work on cubes, cylinders and beams which were cast in laboratory and their behavior under test were observed at 7 & 28 days for compressive strength and at 28 days for density, flexural strength, dynamic modulus of elasticity, abrasion resistance, water permeability and impact resistance. Overall results of this study show that addition of 0.6% (by weight of the concrete) plastic waste with 10% (by weight of cement) replacement of cement by fly ash result an improvement in properties of the concrete than conventional mix.

Effect of waste cement bag fibers on the mechanical strength of concrete

  • Marthong, Comingstarful
    • Advances in materials Research
    • /
    • 제8권2호
    • /
    • pp.103-115
    • /
    • 2019
  • Polypropylene (PP) fibers for making fabric which is used for packing cement have a high strength and high tear resistance. Due to these excellent properties the present study investigates the effect of PP fibers on the mechanical strength of concrete. Mechanical strength parameters such as compressive strength, splitting tensile strength and flexural strength are evaluated. Structural integrity of concrete using Ultrasonic Pulse Velocity (UPV) was also studied. Concrete containing PP fibers in percentage of 0%, 0.15%, 0.25%, 0.5% and 0.75% was developed with a characteristic compressive strength of 25 MPa. Concrete cubes, cylinder and prismatic specimens were cast and tested. It was found that the UPV values recorded for all specimens were of the similar order. Test results indicated the used of PP fibers can significantly improve the flexural and splitting tensile strengths of concrete materials whereas it resulted a decreased in compressive strength. The relative increase in split tensile and flexural strength was optimum at a fiber dosage of 0.5% and a mild decreased were observed in 28 days compressive strength. The findings in this paper suggested that PP fibers deriving from these waste cement bags are a feasible fiber option for fiber-reinforced concrete productions.

고인성 시멘트 복합재료를 사용한 현장타설 끼움벽 골조의 고조성능 (Structural Performance of Cast-In-Place Infill Wall Frames using High Performance Fiber Reinforced Cement Composites)

  • 이혜연;김선우;박완신;이갑원;최창식;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.275-278
    • /
    • 2005
  • High performance fiber reinforced cement composites(HPFRCCs) is a class of high ductile fiber reinforced cementitious composites developed for applications in the sensitive construction industry. HPFRCCs has undergone major evolution in both materials development and the range of emerging applications. This paper is to evaluate structural strengthening performance of LRCF(Lightly reinforced concrete frame) using the HPFRCCs. The experimental results, as expected, show that the crack load, yield load, and limited load are superior for specimen with HPFRCCs infill wall due to crosslink effect of fibers in concrete.

  • PDF

플라이애시 수중불분리성 콘크리트의 수밀성에 관한 실험적 연구 (An Experimental Study on the Water Tightness of Fly Ash Antiwashout Underwater Concrete)

  • 권중현;김봉익
    • 한국해양공학회지
    • /
    • 제22권4호
    • /
    • pp.40-45
    • /
    • 2008
  • This paper describes the effects of fly ash replacement on the water tightness of antiwashout underwater concrete, which replaced the cement with fly ash from 0% to 30%. The experimental work was performed to find out the depth of permeation of concrete specimens cast in air and cured in 23 $^{\circ}C$ tap water using an open center pressure type of water permeation tester. The results showed that the permeation depth values of antiwashout underwater concrete were deeper than normal concrete, but that an admixture using fly ash during antiwashout underwater concrete casting in air made it more watertight than normal concrete according to the water permeation testing. SEM observations of the specimens of fly ash antiwashout underwater concrete showed that it wasmore packed with structures because of the pozzolan reaction of the fly ash and cement.

Traffic-induced vibrations at the wet joint during the widening of concrete bridges and non-interruption traffic control strategies

  • Junyong Zhou;Zunian Zhou;Liwen Zhang;Junping Zhang;Xuefei Shi
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.411-423
    • /
    • 2023
  • The rapid development of road transport has increased the number of bridges that require widening. A critical issue in the construction of bridge widening is the influence of vibrations of the old bridge on the casting of wet joint concrete between the old and new bridges owing to the running traffic. Typically, the bridge is closed to traffic during the pouring of wet joint concrete, which negatively affects the existing transportation network. In this study, a newly developed microscopic traffic load modeling approach and the vehicle-bridge interaction theory are incorporated to develop a refined numerical framework for the analysis of random traffic-bridge coupled dynamics. This framework was used to investigate traffic-induced vibrations at the wet joint of a widened bridge. Based on an experimental study on the vibration resistance of wet joint concrete, traffic control strategies were proposed to ensure the construction performance of cast-in-site wet joint concrete under random traffic without interruption. The results show that the vibration displacement and frequency of the old bridge, estimated by the proposed framework, were comparable with those obtained from field measurements. Based on the target peak particle velocity and vibration amplitude of the wet joint concrete, it was found that traffic control measures, such as limiting vehicle gross weight and limiting traffic volume by closing an additional traffic lane, could ensure the construction performance of the wet joint concrete.

양방향말뚝재하시험의 수치해석 (Numerical Analyses of O-Cell Load Test on Pile)

  • 주용선;김낙경;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.748-753
    • /
    • 2008
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurisation causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. Bi-directional load tests using O-cell are now becoming common practice around the world, particularly where the loads to be applied are high or where it is not convenient to perform top-down loading tests. In the study, calculate ultimate capacity of bi-directional load test using FEM and beam on elasto-plastic foundation theory.

  • PDF

깊은 기초의 건전도시험과 근입깊이 조사 (Integrity test and depth estimation of deep foundations)

  • 조철현;정현기;이태섭;김학수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.202-216
    • /
    • 1999
  • 대형구조물일수록 깊은 기초를 사용하게 된다. 깊은 심도, 대구경의 기초일수록 제자리 기초공법을 채택하는 경우가 많은데 이 때는 적합한 콘크리트의 품질검사와 품질확인 작업이 요구된다. 이를 위해 콘크리트 건전도 시험이 수행된다. 또한 구조물의 개보수 공사 혹은 안전진단시 기초의 건전도와 근입깊이에 대한 정보가 필요하다. 그러나 여러 사정에 의해 기초의 근입깊이를 알 수 없는 경우가 많으므로 이를 알아내기 위한 기법도 요구된다. 음파검층, 탄성파탐사 기법이 이러한 기초구조물의 건전도 시험에 응용되고 있다. 송수신 분리형의 수평검측법은 시공시 매설된 복수의 검측공에서 적용되어 매우 정확한 건전도시험을 수행할 수 있으며, 단일채널 반사법 탄성파탐사는 제자리 기초는 물론 기성말뚝에 대한 건전도시험도 가능하다. 정확도는 검층법이 더 우수하다. 깊은 기초의 근입깊이 조사를 위해서는 평행탄성파법, 시추공레이다법, 시추공자력탐사가 적용될 수 있다.

  • PDF

고성능 중공슬래브의 휨 실험 (Flexural Tests of High Performance Hollow Core Slabs)

  • 박현석;김인규;조영모;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.167-172
    • /
    • 2001
  • Hollow core slabs generally have not been used for a bridge slab or a parking in Korea. In this study, high performance hollow core slabs, which has been the most thick one in domestic are re-designed and examined for practical use. Flexural tests were performed on four 315mm deep hollow core slabs to investigate adaptability for high vehicle live loadings and composite action with topping concrete. The precast slabs were reinforced with 10-l/2 inch dia-strands at the lower of slab and 4-l/2 inch dia-strands at tile upper of slab, and cast with 80mm deep topping concrete. Those tested hollow core slabs showed ductile failure behaviors which were conform to the current Ultimate Strength Design Method for a span of l0m up to the live load of 1, 000 kg/$m^2$.

  • PDF