• 제목/요약/키워드: cast iron pipe

검색결과 43건 처리시간 0.027초

파이프 구조물의 소음 및 진동특성 연구 (A Study on Noise and Vibration Characteristics of Pipe Structures)

  • 류봉조;임경빈;이규섭;송영봉;공용식;오부진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.334-337
    • /
    • 2002
  • The paper presents noise and vibration characteristics of three kinds of pipe materials (PVC pipe, cast-iron pipe and newly developed pp pipe). In order to measure structure bone noise, impact force using small balls was applied to earth pipe. It was confirmed that structure bone noise can be reduced by more large damping materials. Also, transmission loss of pipes depending on the frequency ranges was investigated by using sound source through speakers.

  • PDF

지반 공동 및 매립관의 지반 투과 레이더 탐사 및 이미지 처리 프로그램 개발 (A Ground Penetrating Radar Detection of Buried Cavities and Pipes and Development of an Image Processing Program)

  • 이현호
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.177-184
    • /
    • 2017
  • 최근 한국에서는 많은 지반 침하 사고가 발생하고 있는데, 이는 상하수의 누수 및 손상된 하수관에 기인한 것이다. 본 연구는 지반 침하에 대한 GPR 탐지 데이터의 실증적 자료를 구축하는 것을 목표로 한다. 이러한 목적으로 테스트 베드가 제작되었으며, 제작 변수는 주철관 및 EPS의 매입 깊이 및 수평 거리이다. 탐사결과, 1.5m의 깊이로 매립된 EPS는 검출하기 어려웠으며, 0.5m 거리 내에서 주철관에 밀접하게 매설 된 EPS는 매우 강한 주철관 신호로 탐지가 불가능했다. 또한 본 연구에서는 GPR 탐사 이미지 결과를 처리하기 위해 GPR 이미지 처리 프로그램 (GPRiPP)을 개발했다. 그 주요 기능은 위글파 신호를 증폭시키는 게인 기능이며, 기존 프로그램과 GPRiPP의 이미지 처리 기능은 매우 유사함을 확인하였다.

화장실 배수관에 따른 배수소음 평가 (Rating of Noise Emission by Plumbing system in Bathroom)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.923-927
    • /
    • 2003
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by pipe material, wrapped pipe with glass wool and installed pipe height The characteristics of noise emission from drain-pipes is as follows. The noise reduction pipe in PVC can reduce noise levels in 7-10㏈ and the cast-iron pipe can reduce in 14㏈compared with the normal PVC pipe. In these days, the glass wool was used for preventing the burst and the noise reduction. But the glass wool for wrapping pipe is not effective to the noise reduction. The characteristics of noise emission from various installed pipe height were measured As the ceiling space of the remodeled building was raised, the noise level was troubled by increasing of the vertical pipe length.

  • PDF

배관 결함부 원거리장 와전류 신호 정량화 연구 (Quantitative Evaluation of Remote Field Eddy Current Defect Signals)

  • 정진오;이재경;김형진
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.555-561
    • /
    • 2000
  • 다양한 기계가공 결함을 유기한 공칭 외경 100mm의 덕타일 주철관을 대상으로 원거리장 와전류 검사를 수행하였다. 상수도 배수관으로 사용되는 주철관은 제조 단계의 큰 허용 오차 때문에 두께가 일정하지 않고 단면이 비대칭적인 특징을 지니므로, 원거리장 와전류 탐상 신호에는 배관 축방향에 걸친 장범위 잡음이 존재하게 된다. 본 논문에서는 장범위에 걸친 배경잡음을 효과적으로 제거하기 위하여 이동구간 평균법을 응용하였고, 결함의 깊이와 원주방향 정도를 정량적으로 평가하기 위하여 voltage plane 극좌표 (VPPP) 방법을 활용하였다. 이동구간 평균처리로서 신호비를 일차적으로 향상시킨 다음 VPPP 기법을 이용하여 결함신호를 얻은 결과, 결함신호가 VPPP상의 기준점에서 x 축과 이루는 각이 결함 깊이와 직선적인 상관 관계가 있음을 확인하였다. 따라서 배관과 동축으로 놓인 탐촉코일을 이용한 원거리장 와전류 검사로서 매설 상수도 배관 내 외부에 존재하는 부식결함을 비파괴 정량평가할 수 있는 기반을 구축하였다.

  • PDF

대형 상수관로 노후상태 조사 및 평가에 관한 연구 (Investigation and Assessment of the Deterioration on Aging Large Water Mains)

  • 김주환;배철호;김정현;홍성호;이경재
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.545-558
    • /
    • 2006
  • The current conditions of large water mains are evaluated by deteriorations and the causes of deterioration are investigated through visual assessments in the field, mechanical tests and analysis of chemical compositions in laboratory for each pipe material, unlined cast iron pipes (CIPs), ductile iron pipes (DCIPs) and steel pipes (SPs) Tubercles and scales from internal and external corrosion of unlined cast iron pipes were identified as the causes of functional performance limitations in large water mains. It is investigated that main causes of internal and external corrosion of water pipes are from lots of depositions of organic and inorganic substances on pipe surface, concentrated pitting, and uniform corrosion by local or global exfoliation or detachment of lining and coatings of DCIPs and SPs. Internal and external corrosion depths of CIPs were higher than those of DCIPs and SPs. Consequently, total corrosion rate summed internal and external corrosion rates of CIPs also were shown to be higher than those of DCIPs and SPs. The failure time from hole generation of CIPs by total corrosion rate was predicted to be taken sixteen years, and DCIPs and SPs were twenty-six years and one hundred and fifty three years. And longitudinal deflection of investigated water mains were not happened and mechanical strengths such as tensile strength, elongation, and hardness also were mostly suited to Korea Standards. It was thought that the weakness of tensile strength of one sample(S-11) was, however, due to higher carbon contents(%) in CIPs. Pipe deterioration score of S-46 was 55.2 and was preferentially assessed to be rehabilitated.

부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구 (Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis)

  • 황상용;송호봉
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).

고강도 수도용 PVC관의 성능평가 연구 (Evaluation Method of Plastic Pipe for High-Strength Water Supply)

  • 박종일;이창석
    • 설비공학논문집
    • /
    • 제30권1호
    • /
    • pp.44-49
    • /
    • 2018
  • High-strength plastic water supply pipe evaluation method was evaluated in this study. Up to date, high strength water supply pipes that we install are mostly ductile cast iron pipes. Sometimes, a few PVC pipes are installed. Metal pipes have rust problem on the surface, causing serious damage to metal pipes and reducing the expected life span of water piping system. Nowadays, depending on technology development, some companies have improved properties of general PVC pipe performance with remarkable properties that exceed KS and ASTM standard. Here, we suggest a new method of performance evaluation for high-strength water plastic pipes.

상수도관의 사용연수에 따른 관파괴확률 산정 (Calculations of probability of pipe breakage according to service year)

  • 권혁재;김형기
    • 한국수자원학회논문집
    • /
    • 제52권8호
    • /
    • pp.555-563
    • /
    • 2019
  • 상수도관은 시간이 흐름에 따라 부식이 발생할 수 있으며 이로 인해 관두께가 작아져 기존의 성능을 발휘하기 힘들어진다. 이에 본 연구에서는 관두께 변화에 따른 파괴확률을 정량적으로 산정할 수 있는 수치모형을 개발하였으며 이를 실제 상수도관망에 적용하여 사용연수가 증가함에 따라 파괴확률이 어떻게 변화하는지 분석하였다. 파괴확률은 FORM(First Order Reliability Method)를 사용하여 산정되었고 압력의 통계적 특성을 분석하기 위해 여러 가지 다른 시나리오를 이용하여 부정류해석을 수행하였으며 신뢰함수로는 주장력공식을 개선한 KCIP(Korea Cast Iron Pipe)식을 사용하였다. 또한 부식으로 인한 두께변화를 산정하기 위하여 Nahal and Khelif식과 Romanoff의 식을 사용하였으며 이를 통하여 10년, 20년, 30년 후의 부식으로 인한 관두께를 추정하였고 이에 따른 파괴확률을 산정하여 비교분석하였다. 본 연구에서 적용된 상수도관망A의 경우 Nahal and Khelif의 식을 사용하였을 때 100 mm 직경의 강관이 사용연수가 10년, 20년, 30년으로 증가할 경우 파괴확률은 상수도압 $12kg/cm^2$ 일 때 각각 6.8%, 7.8%, 8.5%로 점진적으로 증가하는 것을 알 수 있었고, Romanoff의 식을 사용하였을 경우 6.4%, 7.5%, 8.9%로 증가하는 것을 확인하였다.

Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과 (The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver)

  • 장미정;성일화
    • 대한환경공학회지
    • /
    • 제33권4호
    • /
    • pp.258-266
    • /
    • 2011
  • 수중 경도물질에 의해 유발된 스케일은 수질 저해는 물론 배관의 기능에 막대한 손실을 초래할 수 있어 관리가 필요하다. 특히 온수시스템의 경우, 온도에 의해 스케일화작용이 가속화되므로 관리가 필요한 시설 중 하나이다. 현재까지는 화학약품이나 에너지가 소모되는 화학적, 물리적, 전자기적 방법과는 다른 무전원방식의 Frequency Driver (FD)를 이용하여 스케일 생성 방지 효과를 확인하고자 하였다. 500 mg/L의 경수에 33일간 3종류의 관 시편을 침지시켜 관 재질별 스케일 형성도를 비교하기 위해 XRD와 SEM을 이용하여 표면을 분석하였다. 주철관에서는 경도에서 유발된 스케일인 calcite ($CaCO_3$)가 형성되었고, 구리나 스테인리스관에 비해 부식율이 높았다. 온수순환장치를 제작하여 경도 300 mg/L로 $50^{\circ}C$의 조건에서 FD 설치 유무에 따른 주철관의 스케일 형성도와 수질 변화를 비교하였다. XRD 결과에서 FD를 설치하였을 경우 calcite의 생성은 비교적 적은 반면, 좋은 부식생성물인 magnetite ($Fe_3O_4$)의 생성을 확인할 수 있었으며, SEM 사진에서도 FD의 스케일 저감 효과를 확인할 수 있었다. 관 내부의 스케일 양의 경우, FD를 설치하지 않은 경우에 비해 FD를 설치하였을 경우 관 연결부분에서는 16%, 관 전체길이에서는 14%, 열교환기에서는 42%의 적은 스케일이 형성되어 FD의 스케일 저감효과를 확인할 수 있었다. 또한 FD 설치 유무에 따른 수질분석 결과를 토대로 FD가 수질의 화학적 변화 없이 경도물질의 결정화를 방지하는 것으로 나타나 환경적으로도 안전함을 확인하였다.

Effect of Dissolved Oxygen (DO) on Internal Corrosion of Water Pipes

  • Jung, Hae-Ryong;Kim, Un-Ji;Seo, Gyu-Tae;Lee, Hyun-Dong;Lee, Chun-Sik
    • Environmental Engineering Research
    • /
    • 제14권3호
    • /
    • pp.195-199
    • /
    • 2009
  • A series of laboratory-scale corrosion experiments was carried out to observe the effect of dissolved oxygen (DO) in the presence of other water quality parameters, such as hardness, Cl-, and pH using various pipe materials. In addition, a simulated loop system was installed at a water treatment plant for pilot-scale experiment. Laboratory-scale experiment showed that corrosion rates for galvanized steel pipe (GSP), carbon steel pipe (CSP), and ductile cast iron pipe (DCIP) were decreased to 72%, 75%, and 91% by reducing DO concentration from 9${\pm}$0.5 mg/L to 2${\pm}$0.5 mg/L. From the pilot scale experiment, it was further identified that the average ionization rate of zinc in GSP decreased from 0.00533 to 0.00078 mg/$cm^2$/d by controlling the concentration of DO. The reduction of average ionization rate for copper pipe (CP) and stainless steel pipe (SSP) were 71.4% for Cu and 63.5% for Fe, respectively. From this study, it was concluded that DO could be used as a major parameter in controlling the corrosion of water pipes.