• Title/Summary/Keyword: cascade control

Search Result 271, Processing Time 0.042 seconds

Velocity Control of Permanent Magnet Synchronous Motors using Model Predictive and Sliding Mode Cascade Controller (슬라이딩 모드 및 모델 예측 직렬형 제어기를 이용한 영구자석형 동기전동기의 속도제어)

  • Lee, Ilro;Lee, Youngwoo;Shin, Donghoon;Chung, Chung Choo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.9
    • /
    • pp.801-806
    • /
    • 2015
  • In this paper, we propose cascade-form velocity controller for a permanent magnet synchronous motor (PMSM). The proposed controller consists of a sliding-mode controller (SMC) for the inner current control loop and a model-predictive controller (MPC) for the outer velocity control loop. With SMC, we can ensure that the current tracking error always converges to zero in finite time. The SMC is designed to track the desired currents. Additionally, with MPC, we can obtain the optimal velocity control input which minimizes the cost function. Constraint conditions for input and input variation are included in the MPC design. The simulation results are included to validate the performance of the proposed controller.

Multivariable Optimal Control of a Direct AC/AC Converter under Rotating dq Frames

  • Wan, Yun;Liu, Steven;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.419-428
    • /
    • 2013
  • The modular multilevel cascade converter (MMCC) is a new family of multilevel power converters with modular realization and a cascaded pattern for submodules. The MMCC family can be classified by basic configurations and submodule types. One member of this family, the Hexverter, is configured as Double-Delta Full-Bridge (DDFB). It is a novel multilevel AC/AC converter with direct power conversion and comparatively fewer required components. It is appropriate for connecting two three-phase systems with different frequencies and driving an AC motor directly from a utility grid. This paper presents the dq model of a Hexverter with both of its AC systems by state-space representation, which then simplifies the continuous time-varying model into a periodic discrete time-invariant one. Then a generalized multivariable optimal control strategy for regulating the Hexverter's independent currents is developed. The resulting control structure can be adapted to other MMCCs and is flexible enough to include other control criterion while guaranteeing the original controller performance. The modeling method and control design are verified by simulation results.

The Cascade PID Type Fuzzy Control Method

  • Lee, Jung-Hoon;Ki whan Eom;Lee, Yong-Gu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.93.3-93
    • /
    • 2001
  • We propose the cascade PID type fuzzy control method for a good performance such as robustness. The one of proposed method, the first stage have two input variables of an error and a derivative error, and one output variable, and the next stage have two input variables of the output of first stage and an integral error, and one output variable, have two stages. The other, the first stage has one input of an error, and one output variable, and the second stage have two input of the output of first stage and a derivative error, and one output variable, and the third stage have two input of the output of the second stage and an integer error, and one output variable ...

  • PDF

Improvement of Conventional Sliding Mode Observer for Full Range Sensorless Control of a PMSM

  • Wibowo, Wahyu Kunto;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.89-96
    • /
    • 2015
  • This paper investigates some strategies to overcome the chattering problem of the conventional sliding mode observer (SMO) and to improve the rotor position estimation performance for full range sensorless control of a PMSM. An adaptive observer gain based on the Lyapunov's stability criterion and a cascade low pass filter with advanced phase delay compensation were proposed to reduce the chattering problem and to strengthen the filtering capability of the SMO. Several cases studies through experiments were carried out to confirm conventional SMO's problems and effectiveness of the proposed strategies. The experimental results show that the proposed method gives precise estimation on speed and rotor position when the motor rotates on 2% of its rated speed.

Nonlinear Control of Cascade Hybrid Mass Dampers considering Stroke Saturation (스트로크 포화를 고려한 직렬 복합형 감쇠기의 비선형 제어)

  • 민경원;황성호;김성춘;호경찬;김인수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.377-386
    • /
    • 2000
  • Hybrid mass dampers consist of passive tuned mass dampers and active mass dampers. They have the advantage that passive tuned mass dampers are still operated even when active mass dampers are stopped by excessive disturbances or power failure. This paper begins first with the comparative analysis of tuned mass dampers, hybrid mass dampers, and active mass dampers. Next more detailed study is carried out on the hybrid mass dampers: cascade hybrid mass dampers (CHMD) and active tuned mass dampers (ATMD). CHMD is regarded as more reasonable device because of its lighter active mass than ATMD's. However CHMD can not neglect stroke saturation problem caused by the length limitation of active damper mass. We compensate the saturation problem with nonlinear restoring force. The restoring force is calculated based on the states and phases of active mass dampers and added to the control force. It is shown that the presented compensation method prevents CHMD from saturation behavior without apparent changes of control force and responses compared to those in case of not considering the saturation problem.

  • PDF

On-line Frequency Estimation Based on Cascade Adaptive Notch Filter and Application to Active Noise Control

  • Kim, Sunmin;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.81-84
    • /
    • 1998
  • For ANC systems applied to aircrafts or passenger ships, engines from which reference signals are usually measured are located so far from seats where main part of controllers are placed. It can make feedforward ANC scheme difficult to implement or very costly. Feedback ANC algorithms which do not require reference signals and use error signals alone to update the filter, are usually sensitive to measurement noise ' and impulse noise. In this paper, reference signal needed for the feedforward control is not measured directly but generated with the estimated frequencies. Cascade adaptive notch filter (ANF), which has the low computational burden, is used to implement ANC system in real time. Several ANFs of order 2 are connected in series to estimate multiple sinusoids. Computer simulations and experiments in the laboratory for verifying efficacy of the proposed algorithm are carried out.

  • PDF

LMI-Based Robust Controllers for DC-DC Cascade Boost Converters

  • Torres-Pinzon, Carlos Andres;Giral, Roberto;Leyva, Ramon
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.538-547
    • /
    • 2012
  • This paper presents two different robust controllers for boost converters with two stages in a cascade. The first robust controller is monovariable; that is, the duty-cycle is the same for the two switches. The monovariable controller ensures that some prescribed constraints on pole placement and control effort are met, and optimizes the load disturbance rejection, while takes into account the uncertainty in certain parameters. The first controller is then compared with a multivariable robust controller; that is, with independent duty cycles in each switch. The multivariable controller takes into account the same uncertainty, constraints and optimization function. The comparison shows that the multivariable controller performs better at the expense of a slightly more complex implementation; that is, the multivariable controller provides a better rejection of the load disturbance. The paper also describes simulations and experimental results that are in perfect agreement with theoretical derivations.

Control of Power Quality Using a High Voltage STATCOM for the Integration of Large Scale Wind Power Plant (고전압 무효전력 보상기를 사용한 대규모 풍력발전 설비의 전력 품질 보상)

  • Kim, Jihong;Song, Seungho;Jeong, Seunggi
    • New & Renewable Energy
    • /
    • v.8 no.4
    • /
    • pp.13-20
    • /
    • 2012
  • This paper describes a transformerless static synchronous campensator (STATCOM) system based on cascade H-bridge multilevel inverter with star configuration. It is designed not only for the dynamic and continuous compensation of the reactive power but also for the improvement of power quality of existing wind power plant. Especially, when the induction generator of wind turbine is directly connected to the grid, reactive power are occurred by exiting current. so a reactive power compensation system based on the cascade H-bridge multilevel STATCOM is proposed because the output power quality and controllability of reactive power are required by grid code in many different countries. Using various The proposed reactive power control strategy using a STATCOM is compared with the conventional scheme using fixed-size of capacitor bank through various simulation results.

Molecular Mechanism of Plant Adaption to High Salinity (식물의 고염 스트레스에 대한 반응 및 적응기작)

  • Yun Dae-Jin
    • Journal of Plant Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • Plant responses to salinity stress is critical in determining the growth and development. Therefore, adaptability of plant to salinity stress is directly related with agriculture productivity. Salt adaptation is a result of the integrated functioning of numerous determinants that are regulated coordinately through an appropriate responsive signal transduction cascade. The cascade perceives the saline environment and exerts control over the essential mechanisms that are responsible for ion homeostasis and osmotic adjustment. Although little is known about the component elements of salt stress perception and the signaling cascade(s) in plant, the use of Arabidopsis plant as a molecular genetic tool has been provided important molecular nature of salt tolerance effectors and regulatory pathways. In this review, I summarize recent advances in understanding the molecular mechanisms of salt adaptation.