• 제목/요약/키워드: carbon steel and stainless steel

검색결과 346건 처리시간 0.027초

수평관내 초임계 영역의 Co2 냉각 열전달 특성 (Heat Transfer Characteristics During Gas Cooling Process of Carbon Dioxide in a Horizontal Tube)

  • 손창효;이동건;오후규;정시영;김영률
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.289-295
    • /
    • 2004
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flowmeter, an evaporator, and a gas cooler(test section). The main components of the water loop consist of a variable-speed pump, an isothermal tank, and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal stainless steel tube of the outer diameter of 9.53mm and of the inner diameter of 7.75mm. The length of the test section is 6m. The refrigerant mass fluxes were 200∼300kg/(m2$.$s) and the inlet pressure of the gas cooler varied from 7.5㎫ to 8.5㎫. The main results were summarized as follows : Pressure drop of CO2 increases with increasing gas cooler pressure. The friction factors of CO2 in a horizontal tube show a relatively good agreement with the correlation by Blasius. The heat transfer coefficient of CO2 in transcritical region increases with decreasing gas cooler pressure and decreasing mass flux of CO2. Most of correlations proposed in a transcritical region showed significant deviations with experimental data except for those predicted by Gnielinski.

심층수 이용 열교환기 개발을 위한 기초연구: 열교환기 부식이 열교환기 성능에 미치는 영향 (A Fundamentals study on Heat Exchanger using Deep Ocean Water: Effects of Corrosion on Heat Transfer Performance)

  • 권영철;이석현;허철;조맹익;이창경;권정태
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5377-5384
    • /
    • 2013
  • 본 논문은 심층수용 열교환기 재질로 티타늄, 알루미늄, 스테인리스, 구리와 알루미늄을 코팅하여 재질의 특성 및 부식이 미치는 영향을 조사하기 위하여 이중관 열교환 실험장치를 활용하였다. 열교환기 재질은 티타늄, 스테인레스, 구리, 알루미늄, 카본 코팅된 알루미늄 등 6종이 비부식관과 부식관에 대하여 해석과 실험이 수행되었다. 해석은 EES 프로그램을 사용하였다. 부식의 영향을 살펴보기 위하여 부식 제조장치를 제작하고, 3.5%의 염수를 $70^{\circ}C$의 온도로 약 6주간 담가서 가속부식을 실시하였다. 부식된 관으로 이중관 열교환기의 성능실험을 실시하여 비부식관과 비교하였다. 실험결과로부터 티타늄을 대체용으로 알루미늄 코팅관(카본 블랙 $150{\mu}m$)의 가능성을 확인하였다.

연마재 워터젯을 위한 노즐상태 모니터링 시스템 설계 (Nozzle Condition Monitoring System for Abrasive Waterjet Process)

  • 김정욱;김노원;김철민;김성렬;김현희;이경창
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.817-823
    • /
    • 2020
  • In recent, the machining of difficult-to-cut materials such as titanium alloys, stainless steel, Inconel, ceramic, glass, and carbon fiber reinforced plastics (CFRP) used in aerospace, automobile, medical industry is actively researched. Abrasive waterjet is a non-traditional processing method in which ultra-high pressure water and abrasive particles are mixed in a mixing chamber and shoot out jet through a nozzle, and removed by erosion due to collision with a material. In particular, the nozzle of the abrasive waterjet is one of the most important parts that affect the machining quality as with a cutting tool in general machining. It is very important to monitor the condition of the nozzle because the workpiece is uncut or the surface quality deteriorates due to wear, expanding of the bore, damage of the nozzle and clogging of the abrasive, etc. Therefore, in this paper, we propose a monitoring system based on Acoustic Emission(AE) sensor that can detect nozzle condition in real time during AWJ processing.

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

바이오매스 가스화장치를 이용한 합성가스 생산에 있어서 연료조건의 영향 (Effects of Biomass Fuel Conditions on Biomass Ossification)

  • 홍성구
    • 한국농공학회논문집
    • /
    • 제48권3호
    • /
    • pp.63-71
    • /
    • 2006
  • A downdraft gasifier was made of stainless steel for biomass gasification. Internal reactor had a 300 mm diameter and 8 air intakes. Three thermocouples were installed to measure the temperature inside the reactor. Three different biomass fuels were provided in the experiments to find out the effects of fuel conditions on gasification processes; charcoals, woodchips, and mixture of woodchip and charcoals. Two different experiments were conducted fer charcoal experiments, small and larger sizes of charcoal fuels. It took about 10 minutes after ignition to generate combustible producer gas when charcoal was f9d, but 20 or more minutes for woodchips. When the gasification was stabilized, the highest temperature was observed just below the combustion zone. The air flow rate for woodchip experiment was provided at 25% of a stoichiometric requirement of combustion, which was within the range of typical air flow rate fer woody biomass gasification. Carbon monoxide concentrations were also within the values reported in the previous studies, ranging 20 to 30% depending on fuel types. It could be seen that fuel size and heating value were very important parameters in biomass gasification. These parameters should be taken into account in operating and designing biomass gasifiers.

수평관과 헬리컬 코일관내 이산화탄소의 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of Carbon Dioxide in a Horizontal and Helically Coiled Tube)

  • 손창효
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.121-126
    • /
    • 2008
  • The cooling heat transfer coefficient of $CO_2$ (R-744) in a horizontal and helically coiled tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, evaporator and gas cooler (test section). The test section consists of a horizontal stainless steel tube and hellically coiled copper tube of 4.57 and 7.75 mm. The experiments were conducted at saturation temperature of 100 to $20^{\circ}C$, and mass flux of 200 to $500kg/m^2s$. The test results showed the variation of the heat transfer coefficient tended to decrease as cooling pressure of $CO_2$ increased. The heat transfer coefficient with respect to mass flux increased as mass flux increased. The experimental results were also compared with the existing correlations for the supercritical heat transfer coefficient, which generally underpredicted the measured data. However, the experimental data showed a relatively good agreement with the correlations of Pitla et al. except for the pseudo critical temperature.

수평관내의 $CO_2$의 증발 열전달에 관한 연구 (Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube)

  • 장승일;최선묵;김대희;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Synthesis of Silver Nanoparticles using Pulse Electrolysis in 1-n-butyl-3-methylimidazolium Chloride Ionic Liquid

  • Jeonggeun Jang;Jihee Kim;Churl Kyoung Lee;Kyungjung Kwon
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.15-20
    • /
    • 2023
  • Ionic liquids are considered as a promising, alternative solvent for the electrochemical synthesis of metals because of their high thermal and chemical stability, relatively high ionic conductivity, and wide electrochemical window. In particular, their wide electrochemical window enables the electrodeposition of metals without any side reaction of electrolytes such as hydrogen evolution. The electrodeposition of silver is conducted in 1-n-butyl-3-methylimidazolium chloride ([C4mim]Cl) ionic liquid system with a silver source of AgCl. This study is the first attempt to electrodeposit silver nanoparticles without using co-solvents other than [C4mim]Cl. Pulse electrolysis is employed for the synthesis of silver nanoparticles by varying applied potentials from -3.0 V to -4.5 V (vs. Pt-quasi reference electrode) and pulse duration from 0.1 s to 0.7 s. Accordingly, the silver nanoparticles whose size ranges from 15 nm to ~100 nm are obtained. The successful preparation of silver nanoparticles is demonstrated regardless of the kinds of substrate including aluminum, stainless steel, and carbon paper in the pulse electrolysis. Finally, the antimicrobial property of electrodeposited silver nanoparticles is confirmed by an antimicrobial test using Staphylococcus aureus.

이온 플레이팅의 TiN코팅층에 미치는 작업인자의 영향 (The Effects of Process parameters on TiN Films deposited by Ion Plating Technique)

  • 백응승;권식철;이상로;이건환
    • 한국표면공학회지
    • /
    • 제23권2호
    • /
    • pp.24-29
    • /
    • 1990
  • The TiN filmms were deposited on the stainless steel substrates by BARE techinique in order to investigate the effects of process parameters such as source-to-substate distance (15-35cm), N2 pressure(4$\times$10-10 -1$\times$10-3mb)and bias voltage(O-2000V), on the deposition rate, the concentration ratio [N/Ti] and the surface color of the films. The deposition rate was deduced from the weight measurement, the [N/ti] ratio by ESCA. The deposition rate decreased with a relationship of=40.2/D2 where D was source-to-substrate distance. The effect of the bias voltage and the N2pressure on the deposition rate, however, appeared negligble. The [N/Ti] ratio was in the narrow range of 0.7 tp 0.8 It increased slightly with the N2 partial pressure and deceased with the source-to-substrate distance. It was confired by ESCA that a significant amount of oxygen and carbon was contaminated after deposition in the top surface of TiN films. The surface color of TiN film was changed from light gold yellow to reddish gold yellow with increasing [N/Ti] ratio.

  • PDF

A Study of the Couplant Effects on Contact Ultrasonic Testing

  • Kim, Young-H.;Song, Sung-Jin;Lee, Sung-Sik;Lee, Jeong-Ki;Hong, Soon-Shin;Eom, Heung-Seop
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.621-626
    • /
    • 2002
  • The amplitude of a back-wall echo depends on the reflection coefficient of the interface between a transducer and a test material when using contact pulse-echo ultrasonic testing. A couplant is used to transmit ultrasonic energy across the interface, but has an influence on the amplitude of the pulse-echo signal. To investigate the couplant effect on pulse-echo ultrasonic testing, back-wall echoes are measured by using various couplants made of water and glycerine in a carbon and austenitic stainless steel specimens. The amplitude of the first back-wall echo and the apparent attenuation coefficient increases with the acoustic impedance of the couplant. The couplant having a higher value of the transmission coefficient is more effective for flaw detection. The reflection coefficient should be known in order to measure the attenuation coefficient of the test material.