• 제목/요약/키워드: carbon monoxide gas

검색결과 377건 처리시간 0.027초

Pt 및 Pt-$SnO_2$를 전극으로 하는 SiC 쇼트키 다이오드의 CO 가스 감응 특성 (A study on CO gas sensing Characteristics of Pt-SiC $SnO_2$-pt-SiC Schottky Diodes)

  • 김창교;노일호;양성준;이재홍;이주헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.805-808
    • /
    • 2002
  • A carbon monoxide gas sensor utilizing Pt-SiC, Pt-SnO2-SiC diode structure was fabricated. Since the operating temperature for silicon devices in limited to 200oC, sensor which employ the silicon substrate can not at high temperature. In this study, CO gas sensor operating at high temperature which utilize SiC semiconductor as a substrate was developed. Since the SiC is the semiconductor with wide band gap. the sensor at above $700^{\circ}C$. Carbon monoxide-sensing behavior of Pt-SiC, Pt-SnO2-SiC diode is systematically compared and analyzed as a function of carbon monoxide concentration and temperature by I-V and ${\Delta}$I-t method under steady-state and transient conditions.

  • PDF

Characterization of ZnO Nanorods and SnO2-CuO Thin Film for CO Gas Sensing

  • Lim, Jae-Hwan;Ryu, Jee-Youl;Moon, Hyung-Sin;Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.305-309
    • /
    • 2012
  • In this study, ZnO nanorods and $SnO_2$-CuO heterogeneous oxide were grown on membrane-type gas sensor platforms and the sensing characteristics for carbon monoxide (CO) were studied. Diaphragm-type gas sensor platforms with built-in Pt micro-heaters were made using a conventional bulk micromachining method. ZnO nanorods were grown from ZnO seed layers using the hydrothermal method, and the average diameter and length of the nanorods were adjusted by changing the concentration of the precursor. Thereafter, $SnO_2$-CuO heterogeneous oxide thin films were grown from evaporated Sn and Cu thin films. The average diameters of the ZnO nanorods obtained by changing the concentration of the precursor were between 30 and 200 nm and the ZnO nanorods showed a sensitivity value of 21% at a working temperature of $350^{\circ}C$ and a carbon monoxide concentration of 100 ppm. The $SnO_2$-CuO heterogeneous oxide thin films showed a sensitivity value of 18% at a working temperature of $200^{\circ}C$ and a carbon monoxide concentration of 100 ppm.

$SnO_2$계 일산화탄소 가스 감지 소자의 주위온도, 습도 의존성에 관한 연구 (Dependency of SnO2 System Carbon Monoxide Gas Sensor on the Atmospheric Temperature & Humidity)

  • 정형진;김종만;이전국
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1004-1010
    • /
    • 1990
  • SnO2-ThO2-PdCl2-In2O3 gas sensing ceramic systems were studied in order to lowr the operating temperatures and reduce the dependence of ambient temperatures and humidities. Sensing materials were coated by brush on the alumina tube followed by the impregnation of solidfier(ethylsilicate). Coated species were dried and sintered at 75$0^{\circ}C$ for 30min. carbon monoxide gas detecting sensitiviteis were measured in various ambinet temperatures and humidities. In the composition of 94SnO2-5ThO2-PdCl2 system carbon monoxide gas detecting sensors showed the highest detecting sensitivities and the lowest operating temperature(15$0^{\circ}C$). As the ambient temperatures and humidities were increased, sensitivities were decreased. Because the oscillation effects were observed at high humidities, it was suggested that the sensitivities of sensors depend greatly on the humidities.

  • PDF

수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향 (Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell)

  • 권준택;김준범
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

귀금속촉매 (Pt, Pd)를 이용한 일산화탄소 산화반응에 관한 연구 (A Study of Carbon Monoxide Oxidation on Pt & Pt-Pd Catalysts)

  • ;이원묵;유홍진
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.43-51
    • /
    • 1985
  • This study is concerned with the oxidation of carbon monoxide on platinum and platinum-palladium catalysts. Catalysts were made by the impregnation method and flow reactor was used in the catalytic reaction. As for the mixed gases, carbon monoxide concentration varied from 1 to 4% and that of oxygen from 1 to 4%. $N_2$ was used as carrier gas and GHSV varied from 24, 000 $h^{-1} to 60, h^{-1}$. The temperature range was from 200 to $600^\circ$C. It was also taken into consideration that the heat and mass transfer resistance of our catalysts was negligible in the study. Experimental results showed that platinum-palladium catalyst was about 1.5-3.9% superior to platinum catalyst in conversion yield. When we used platinum-palladium catalyst, we observed that carbon monoxide oxidation was found to be 1 st order with respect to carbon monoxide concentration. Activation energy of the catalyst was 23.5 kcal/mol.

  • PDF

저귀금속 $LaSrNiCoO_3$ 촉매에 의한 자동차 배기중의 일산화탄소의 산화반응에 관한 연구 (A Study on the Oxidation of Carbon Monoxide for Exhaust of Car Engine by the $LaSrNiCoO_3$ Low Noble Metal Catalyst)

  • 이근배;이석희
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.57-72
    • /
    • 1990
  • The oxidation of carbon monoxide on a catalyst, $LaSrNiCoO_3$ was investigatigated with a plug flow system. Kinetic quantities such as reaction-rate, reaction order and Arhenius-parameters at various reactor temperature from 200$^\circ$C to 300$^\circ$C were determined. Also, the optimum condition for the oxidation of carbon monoxide with this catalyst was determined and are as follows. Partial pressure of oxigen ; 428mmHg Partial pressure of carbon monoxide ; 332mmHg Mixed moral ratio of oxigen and Carbon monoxide ; 1.3 : 1 Total gas flow ; 224ml/min Reaction temperature ; 340$^\circ$C The reaction kinetic equation at the optimum condition, temperature range from 200$^\circ$C to 340$^\circ$C, are as follow. $$ $v = Ae^{6.5Kcal/RT} [CO]^{0.93 \sim 0.98} [O_2]^{0.42 \sim 0.50}$ $$ In addition to this, numerical calculation were performed to evaluate the mass and heat transfer effect on this system.

  • PDF

가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발 (The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology)

  • 박찬일;류기윤
    • 한국가스학회지
    • /
    • 제25권3호
    • /
    • pp.27-38
    • /
    • 2021
  • 본 연구에서는 가스보일러 가동 중 배기통이 이탈하는 상황이 발생했을 때, 시스템적으로 인지하고 자동으로 보일러 가동을 중지하여 일산화탄소를 포함한 유해 배기가스가 실내로 유입되는 상황을 근원적으로 차단하는 방안을 제시하였다: (1) 연소에 필요한 공기량을 제어하기 위해 설치된 풍압센서(APS : Air Pressure Sensor)의 출력전압을 측정하여 배기통의 정상상태와 이탈상태를 감시하는 기능을 추가한다. (2) 배기통이 이탈하면 APS의 출력전압이 상시 운전범위에서 일시적으로 상승하게 된다. 보일러 제어부인 PCB가 이 상태를 배기통 이탈로 간주하여 보일러 가동을 멈추면서 배기통 이탈 상태를 실내온도 조절기에 표시하도록 한다. 또한 국토교통부령으로 정한 「건축물의 설비기준 등에 관한 규칙」에서 명시한 공동주택 및 다중이용시설의 환기시설 기준에 따라, 실내공기 교환횟수에 맞는 풍량을 적용하여 실내공기를 환기하는 실험을 실시하였다. 이 실험 결과 실제 일산화탄소가 실내에 누출된 최악의 상태에서, 중독사고 예방이 가능하다는 것을 확인하였다. 다만, 동 규칙에서 정의한 시간당 실내공기 교환횟수를 기존 0.7회에서 0.5회로 2013년부터 완화하여 운영하고 있는데, 실험결과 8시간 가중평균 노출기준인 TWA 30 ppm을 초과하는 농도가 측정되어 기준을 강화할 필요성이 있다. 본 연구 결과에 기초하여 가스보일러 배기압력의 기계적 인지를 통해 배기통 이탈을 감지하는 기술과 일산화탄소 경보기와 연동된 실내공기 환기시스템 기술을 도입한다면 일산화탄소 중독사고가 크게 감소될 것으로 판단된다. 제조 및 검사단계의 문제점을 보완하고, 올바른 설치 및 수리, 사용자의 배기통 이탈에 대한 관심이 더해졌을 때, 일산화탄소 중독으로 인한 인명사고를 예방하는데 효과적인 대책이 될 것으로 사료된다.

RISK EVALUATION OF CARBON MONOXIDE IN COMPARTMENT FIRE

  • Kim, Kwang Il
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.66-76
    • /
    • 1997
  • In order to investigate the generation of carbon monoxide and heat loss of incomplete combustion in compartment fires, an experiment was conducted in a small scale compartment by using methanol as a fuel. The concentration of carbon monoxide and the toxicity parameter showed high values when the mass air - to - fuel stoichiometric ratio is under 1.0. The constitution of the combustion gas was showed to estimate it from the . The heat loss due to incompleteness of combustion is about one third of heat of combustion in case of under 1.0.

  • PDF

당류 중에서 일산화탄소의 발생에 관한 연구 (Generation of Carbon Monoxide from Saccharides)

  • 김남이;서중석;박성우
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.522-529
    • /
    • 2001
  • 알데히드 기를 가지는 당류가 알칼리 용액 하에서 발생되는 일산화탄소를 알칼리의 농도, 반응 온도 및 시간에 따라 분석하였다. 락토스를 포함하고 있는 우유에서 $25^{\circ}C$$40^{\circ}C$의 조건으로 1.0 M NaOH와 0.01 M NaOH 용액 하에서 생성되는 일산화탄소를 정량 분석하였다. 또한 0.1 M lactose와 0.1 M xylose 각각 20 mL와 1.0 M NaOH용액 2 mL를 $50^{\circ}C$에서 48시간 동안 반응시키면서 발생되는 일산화탄소를 신선한 혈액에 bubbling 시킨 다음 그 혈액에서 일산화탄소-헤모글로빈의 농도를 측정한 결과 일산화탄소-헤모글로빈의 농도가 31%였으며, 일산화탄소-헤모글로빈 특유의 UV spectrum을 얻을 수 있었다. 같은 방법으로 우유 30 mL에 20 mL의 1.0 M NaOH를 가하여 $50^{\circ}C$에서 48시간 72시간동안 반응시키면서 발생되는 일산화탄소를 신선한 혈액에 bubbling 시킨 다음 혈중 일산화탄소-헤모글로빈의 농도를 측정한 결과 일산화탄소-헤모글로빈의 농도는 각각 32%와 42%를 나타내었다.

  • PDF

임내 낙엽층의 연소 방출가스 분석 및 건강 위험성 평가 (Combustion Emission Gas Analysis & Hazard Assessment to the Litter Layer in Forest)

  • 김동현;이명보
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.358-364
    • /
    • 2009
  • 본 연구에서는 우리나라 주요 침엽수종인 소나무(Pinus densiflora)와 활엽수종인 굴참나무(Quercus variabilis)의 낙엽에 대해 FTIR(Fourier Transform Infrared) 분광계를 이용하여 배출 연소가스 종류 및 농도를 측정하였다. 실험결과 소나무와 굴참나무 낙엽에서 Carbon monoxide, Carbon dioxide, Acetic acid, Butyl acetate, Ethylene, Methane, Methanol, Nitrogen dioxide, Ammonia, Hydrogen Fluoride, Sulfur dioxide, Hydrogen bromide 등 13개 연소가스가 검출되었고 굴참나무 낙엽에서는 Nitrogen monoxide가 추가로 검출되었다. 방출된 연소가스의 전체 농도는 소나무 낙엽이 굴참나무 낙엽에 비해 4.5배 많이 검출되었다. 특히, 시간가중평균가스농도(TWA : Time-weighted average, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide, Butyl acetate가 검출되었고 단시간노출기준(STEL : Short Term Exposure Limit, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide로 소나무 및 굴참나무 모두에서 나타났다. 이에 산불에서의 낙엽층 지표화 연소시 전체 가스 방출량의 99% 이상을 차지하고 있는 Carbon monoxide, Carbon dioxide의 건강 위험성이 높은 것으로 나타났다. 하지만, 검출된 다른 건강 위험성 가스의 경우에도 연소물질의 양이 증가할수록 연소가스의 농도가 높아져 건강안정성에 해가 있을 것으로 판단되며 또한 검출된 연소가스 중 나무의 주요구성 원소가 아닌 Bromide, Fluoride 화합물에 대해서는 토양으로부터의 오염 또는 분석과정에서의 노이즈로 인한 검출 등에 대한 보다 면밀한 검토가 필요할 것으로 판단된다.

  • PDF