• 제목/요약/키워드: capillary electrophoresis (CE)

검색결과 55건 처리시간 0.137초

모세관 전기영동 분석법의 복합약물제제의 품질관리 분석에 응용을 위한 연구 (Application of Capillary Electrophoresis for Quality Control Analysis of Complex Medicine)

  • 허유정;이공주
    • 약학회지
    • /
    • 제41권5호
    • /
    • pp.539-546
    • /
    • 1997
  • Capillary electrophoresis (CE) is perceived as an attractive tool for the analysis of pharmaceuticals and biological materials because of their high separation efficiency, easy separation and low running cost. New concept of micellar electrokinetic capillary chromatography (MECC) expanded the application of CE to the separation of neutral molecules. Validation of CE as an analytical technique for quality control of pharmaceuticals should be confirmed by quantitative analysis and the peak confirmation. In this study, the quantitative analyses of various types of neutral, acidic and basic components (acetaminophen, caffeine, ascorbic acid, riboflavin, thiamine, chlorpheniramine, phenylpropanolamine, dl-methylephedrine and dextromethorphan) in complex cold medicines have been accomplished using CE. Combined methods of MECC using SDS and capillary zone electrophoresis lowering the pH of running buffer were adopted to determine the ingredients in capsule type or liquid formula complex medicines without particular sample pretreatment. The results indicate that CE is a promising technique for quality control analysis of pharmaceuticals as a validation method.

  • PDF

Applications of Capillary Electrophoresis and Microchip Capillary Electrophoresis for Detection of Genetically Modified Organisms

  • Guo, Longhua;Qiu, Bin;Xiao, Xueyang;Chen, Guonan
    • Food Science and Biotechnology
    • /
    • 제18권4호
    • /
    • pp.823-832
    • /
    • 2009
  • In recent years, special concerns have been raised about the safety assessment of foods and food ingredients derived from genetically modified organisms (GMOs). A growing number of countries establish regulations and laws for GMOs in order to allow consumers an informed choice. In this case, a lot of methods have been developed for the detection of GMOs. However, the reproducibility among methods and laboratories is still a problem. Consequently, it is still in great demand for more effective methods. In comparison with the gel electrophoresis, the capillary electrophoresis (CE) technology has some unique advantages, such as high resolution efficiency and less time consumption. Therefore, some CE-based methods have been developed for the detection of GMOs in recent years. All kinds of CE detection methods, such as ultraviolet (UV), laser induced fluorescence (LIF), and chemiluminescence (CL) detection, have been used for GMOs detection. Microchip capillary electrophoresis (MCE) methods have also been used for GMOs detection and they have shown some unique advantages.

핫 엠보싱 공정을 이용한 플라스틱 CE(capillary electrophoresis) 마이크로 칩의 제작 (Fabrication of plastic CE (capillary electrophoresis) microchip by hot embossing process)

  • 차남구;박창화;임현우;박진구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1140-1144
    • /
    • 2005
  • A plastic-based CE (capillary electrophoresis) microchip was fabricated by hot embossing process. A Si mold was made by wet etching process and a PMMA wafer was cut off from 1mm thick PMMA sheet. A micro-channel structure on PMMA substrate was produced by hot embossing process using the Si mold and the PMMA wafer. A vacuum assisted thermal bonding procedure was employed to seal an imprinted PMMA wafer and a blank PMMA wafer. The results of microscopic cross sectional images showed dimensions of channels were well preserved during thermal bonding process. In our procedure, the deformation amount of bonding process was below 1%. The entire fabrication process may be very useful for plastic based microchip systems.

  • PDF

Capillary electrophoresis를 이용한 한국산 및 중국산 고사리의 원산지 판별방법 개발 (Development of the Discrimination Methods for Geographical Origin of Bracken(Pteridium aquilinum) by Capillary Electrophoresis)

  • 김은영;김정현;정경숙;류미라
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.192-197
    • /
    • 2004
  • The discrimination of bracken (Korean vs. Chinese) has been attempted using capillary electrophoresis (CE). Bracken (Pteridium aquilinum) was extracted with 30% methanol and separated on a uncoated fused-silica ($50{\mu}m{\times}27cm$) capillary. Conditions for optimal analysis include: temperature, $40^{\circ}C$; voltage, 8 kV; and pressure injection time, 5 sec. The optimal separation buffer was 0.3 M borate buffer (pH 8.5) containing 40 mM CHAPS with 30% ethylene glycol. Under the optimal conditions established for CE, the ratio of specific peak area (peak PA-1) to other peak area (peak PA-2) was effective in discrimination of Korean and Chinese bracken. The mean accuracy for discrimination of Korean and Chinese brackens were 80% and 86%, respectively.

모세관전기영동장치 및 고속액체 크라마토그래피에 의한 황금의 성분 분석법 비교 (Studies on the Comparison of Scutellaria Radix Analyses by CE and HPLC)

  • 면노홍;김효진
    • 약학회지
    • /
    • 제43권4호
    • /
    • pp.429-436
    • /
    • 1999
  • A simple, accurate and reproducible Capillary electrophoresis (CE) assay has been developed for the determination of baicalin, baicalein, wogonin and chrysin in Scutellaria baicalensis. Successful separation of these compounds has been obtained in 35 mM phosphate butter (pH 7.0) using a untreated fused silica capillary ($57{\;}cm{\times}75{\;}{\mutextrm{m}}$ i.d.) at $25^{\circ}C$ with the electric field of 19kV. Baicalin, baicalein wogonin and chrysin was separated and detected at 280 nm 13 min. The detection limits of CE were acceptable compared to HPLC. Reproducibilities of migration time and peak area were 0.66~1.11% (within-run), 2.18~3.38% (between-run) and 3.50~4.55% (within-run), 3.97~4.82%(between-run) at CE. The results indicate that CE could be a promising technique for quality and quantity control analysis of Scutellaria baicalensis as a validation method.

  • PDF

Analysis of Inorganic Anions in Various Drinking Waters by Capillary Electrophoresis

  • Choi, One-Kyun;Cho, Jae-Sun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.835-841
    • /
    • 1995
  • The quantitation of inorganic anions in various drinking waters were investigated using capillary electrophoresis(CE) and the results were compared with ion chromatography(IC). With CE, in contrast to IC, was demonstrated rapid analysis, good efficiency, a low detection limit and the low comsumption of a solvent and samples. CE analysis was used 5 mM sodium chromate(pH 8.0) containing 20 mM tetraalkylammoniumbromide at -25kV applied voltage with indirect UV detection at 254 nm. This results in exceedingly short analysis time within 3 min. with efficiencies approaching 200,000 theoretical plates. The coefficients of variants of migration time are less than 0.8% and those of peak area are less than 2.3%. Detection limits for quantitative determination were 300 ppb-50 ppm level. These optimum conditions are applicable to various samples without pretreatment.

  • PDF

모세관 전기영동 장치용 Photodiode Array 다채널 검출기의 개발에 관한 연구 (Development of a Multi - channel Detector for Capillary Electrophoresis System)

  • 홍승국;김해동
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.96-104
    • /
    • 1998
  • 수 많은 광검출기들이 직선으로 집적된 광다이오드 어레이를 이용한 모세관 전기영동장치용 다채널 검출기를 개발하였다. 본 연구에서 사용된 광다이오드 어레이는 1024개의 광검출소자를 가지고 있으며 275~675 nm 파장범위에서 시료의 흡수분광스펙트럼을 검출할 수 있다. 이 장치는 30 ms내에 전 파장영역의 스펙트럼을 얻을 수 있으며, PC에 의하여 시료분석에 필요한 여러 가지 조건들을 제어할 수 있도록 설계하였다. 개발된 검출기의 성능을 L-ascorbic acid와 alizarin yellow GG를 사용하여 시험하였다. 본 연구에서 개발한 모세관 전기영동장치용 다채널 검출기의 재현성 실험결과 상대 표준편차는 5.6%이었다.

  • PDF

Simultaneous enantioseparation of $\beta$-blockers by chiral capillary electrophoresis in reversed polarity mode

  • Kim, Jiyung;Kim, Hang-Han;Kim, Kyoung-Rae
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.214.3-214.3
    • /
    • 2003
  • The chiral separation of multiple ${\beta}$-blockers is described for their accurate chiral discrimination by chiral capillary electrophoresis (CE). The cyc1odextrin-modified CE system was operated in the reversed polarity mode. In this mode, fairly good enantiomeric resolutions were achieved. Relative migration times to internal standard under optimum conditions were characteristic of each enantiomer with good precision. Therefore, in this study, the usefulness for the chiral separation and accurate identification will be discussed.

  • PDF

모세관 전기영동법을 이용한 제제중의 수용성 비타민 분석 (Analysis of Water-soluble Vitamins in Pharmaceutical Products by Capillary Electrophoresis)

  • 이종진;문동철;이공주
    • 약학회지
    • /
    • 제38권1호
    • /
    • pp.38-45
    • /
    • 1994
  • An analytical method using capillary electrophoresis (CE) was developed for quantitation of water soluble vitamin contents in various vitamin products. The method includes the optimization of separation of 11 water soluble vitamins changing the micellar concentration and pH of running buffer, applied voltage and sample preparation. Best resolution was obtained with 25 mM phosphate buffer (pH=8.0) containing 50 mM sodium dodecyl sulphate (SDS) as micellar phase. At optimum condition, water soluble vitamins were determined in orange juice and vitamin products such as vitamin C pulvis, vitamin injection, coated multivitamin tablet. The quantitative analysis of water soluble vitamins with CE was suitable for quality control of pharmaceutical products with sound reproducibility.

  • PDF

Analysis of Branched PEG-Conjugated Interferon Alpha by Capillary Electrophoresis and MALDI- TOF Mass Spectrometry

  • Na, Dong-Hee;Park, Eun-Ji;Lee, Snag-Deuk;Jo, Young-Woo;Lee, Sung-Hee;Kim, Won-Bae;Lee, Kang-Choon
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.406.3-407
    • /
    • 2002
  • Analysis of interferon alpha (IFN) modified with high molecular weight branched PEG was performed by capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MALDI-TOF MS). IFN was modified by the reaction of amine residues with an active ester of monomethoxy polyethylene glycol at various molar ratios. As a CE method. capilary electrophoresis sodium dodecyl sulfate nongel sieving (CE-SDS NGS) was performed using an uncoated capilary filled with a hydrophilic replaceable polymer network matrix. (omitted)

  • PDF