• 제목/요약/키워드: capillary design

검색결과 130건 처리시간 0.037초

수퍼커패시터용 Co/PVA복합전극의 전기화학적특성 (Electrochemical characteristics of Co/PVA composite electrode for supercapacitor)

  • 이희우;김한주;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.577-580
    • /
    • 2001
  • Very fine cobalt oxide ambigel powder were prepared using a unique solution chemistry associated with the sol-gel process. The mesoporous structure of the initial gel is maintained by removing fluid under conditions where the capillary forces that result extraction are either low or no existent, are either low or nonexistent. Controling both the pore and solid architecture on the nanoscale offers a strategy for the design of supercapacitor. But $CoO_{x}$ have the low voltage, so we experiment using CO/PVA composite electrode.

  • PDF

다양한 합성방법으로 제조된 망간옥사이드 전극들의 수퍼커패시터에 대한 응용 (Application on Supercapacitor of Manangese Oxide Electrodes Prepared by Various Synthesis Methods)

  • 김한주;신달우;김용철;김성호;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.606-609
    • /
    • 2000
  • We describe the preparation of a manganese oxide polymorph in which the solid-pore architecture of the material is controllably varied. All MnO$_2$ gels derived from a KMnO$\_$4/-based sol-gel synthesis. The mesoporous structure of the initial gel is maintained by removingore fluid under conditions where the capillary forces that result fro extraction are either low or no existent. are either low or noexistent. Controlling both the pore and solid architecture on the nanoscale offers a strategy for the design of supercapacitor.

  • PDF

마이크로 쿨러 증발기의 비등 전 과도열전달 해석 (Transient Heat Transfer Analysis on the Evaporator of a Micro-Cooler prior to Roiling)

  • 박병규;김근오
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.211-218
    • /
    • 2002
  • It has been investigated for the temperature profile in a planar evaporator of micro-cooler subject to a uniform heat flux prior to tole initiation of boiling. The results of the analysis allow for the determination of applied power levels fur which nucleation is likely to occur only within the vapor grooves of the evaporator while maintaining subcooling in the liquid core, thereby increasing the likelihood of a successful startup. Also, limits are fecund for which additional increases in the applied heat flux do not increase the temperature difference between the vapor grooves and the wick-liquid core interface. This analysis is appropriate for the microscale evaporators of micro-cooler during a fully-flooded startup as well as starter pump designs and micro-CPLs(capillary pumped loops). The results are useful in the initial basic design of microscale heat transfer devices.

상용 Gentoo 폴리머가 경화된 고체주입표면에서 물방울 거동 (Water droplet behavior on a solid-infused surface cured with commercial Gentoo polymer)

  • 김형원;김정현
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.61-67
    • /
    • 2024
  • In this study, the behavior of water droplets on a solid-infused surface was evaluated by quantifying a water droplet's contact angle, sliding angle, and terminal velocity. The contact angle hysteresis and sliding angle of water on the solid-infused surface were measured to be lower than those of the hydrophobic PTFE surface. It led to the enhancement of the initiation of the water droplet's movement. When the capillary number was lower than Ca < 0.004, the terminal velocity of the water droplet on the solid-infused surface was higher than the PTFE surface due to the low contact line resistance. However, the transition of the droplet morphology from a hemispherical shape to a streamlined teardrop shape beyond Ca > 0.004 lost the effect of reducing frictional resistance on the solid-infused surface.

고성능 하드 디스크 드라이브 개발을 위한 유체베어링 스핀들 모터의 특성분석(현장개발사례: SAMSUNG HDD ′SPINPOINT POLARIS SERIES′) (Experimental Characterization of Hydrodynamic Bearing Spindle Motor for High Performance Hard Disk Drive)

  • 손영;황태연;한윤식;강성우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.930-935
    • /
    • 2001
  • The experimental characterization of hydrodynamic bearing spindle motor is performed for the practical implementation of high-performance hard disk drive system. Firstly, the design concept of hydrodynamic bearing for the disk drive system is addressed including the herringbone grooved journal bearing, the spiral grooved thrust bearing, capillary seal design, and the viscous pumping of fluid. Secondly, the experimental evaluation is performed for the disk drive system in which the hydrodynamic bearing spindle motor is implemented and its dynamic performances are compared with conventional ball-bearing spindle motor. The key parameters include NRRO(Non Repeatable Run-Out), disk dynamics, acoustics, and resultant PES (Position Error Signal). Finally, the external gyro-exciting test results including 200k CSS(Continuous Start-Stop) on three angular attitudes(0,90, 180 degree) are presented in order to verify the practical reliability of disk drive system subject to the gyro-motion of hydrodynamic bearing spindle motor.

  • PDF

공압제진대용 이중챔버형 공압스프링의 복소강성 모형화 (Amplitude-dependent Complex Stiffness Modeling of Dual-chamber Pneumatic Spring for Pneumatic Vibration Isolation Table)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.110-122
    • /
    • 2008
  • Pneumatic vibration isolator typically consisting of dual-chamber pneumatic springs and a rigid table are widely employed for proper operation of precision instruments such as optical devices or nano-scale equipments owing to their low stiffness- and high damping-characteristics. As environmental vibration regulations for precision instruments become more stringent, it is required to improve further the isolation performance. In order to facilitate their design optimization or active control, a more accurate mathematical model or complex stiffness is needed. Experimental results we obtained rigorously for a dual-chamber pneumatic spring exhibit significantly amplitude dependent behavior, which cannot be described by linear models in earlier researches. In this paper, an improvement for the complex stiffness model is presented by taking two major considerations. One is to consider the amplitude dependent complex stiffness of diaphragm necessarily employed for prevention of air leakage. The other is to employ a nonlinear model for the air flow in capillary tube connecting the two pneumatic chambers. The proposed amplitude-dependent complex stiffness model which reflects dependency on both frequency and excitation amplitude is shown to be very valid by comparison with the experimental measurements. Such an accurate nonlinear model for the dual-chamber pneumatic springs would contribute to more effective design or control of vibration isolation systems.

CO2 냉각모듈을 적용한 고곡률 성형품의 사출금형 급속냉각 (Rapid cooling of injection mold for high-curvature parts using CO2 cooling module)

  • 이세호;이호상
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.67-74
    • /
    • 2022
  • Injection molding is a cyclic process comprising of cooling phase as the largest part of this cycle. Providing efficient cooling in lesser cycle times is of significant importance in the molding industry. Recently, lots of researches have been done for rapid cooling of a hot-spot area using CO2 in injection molding. The CO2 flows under high pressure through small, flexible capillary tubes to the point of use, where it expands to create a snow and gas mixture at a temperature of -79℃. The gaseous CO2 removes heat from the mold and releases it into the atmosphere. In this paper, a CO2 cooling module was applied to an injection mold in order to cool a large area cavity uniformly and quickly, and the cooling performance of the injection mold was investigated. The product was a high-curvature molded part with a molding area of 300x100mm. Heat cartridges were installed in a stationary mold, and CO2 cooling module was inserted inside a movable mold. Through structural analysis, it was confirmed that the maximum deformation of mold with CO2 cooling module was 0.09mm. A CO2 feed system with a heat exchanger was used for cooling experiments. The CO2 was injected into the holes on both sides of the supply pipe of the cooling module and discharged through hexagon blocks to cool the mold. It took 5.8 seconds to cool the mold from an average temperature of 140℃ to 70℃. Through the experiment using CO2 cooling module, it was found that a cooling rate of up to 12.98℃/s and an average of 10.18℃/s could be achieved.

발반사요법 교육프로그램이 당뇨병 환자의 발관리에 미치는 효과 (The Effects of a Foot-Reflex-Massage Education Program on Foot Care in Diabetic Patients)

  • 이영희
    • 대한간호학회지
    • /
    • 제33권5호
    • /
    • pp.633-642
    • /
    • 2003
  • Purpose: This study was conducted to evaluate the effects of foot care education program using foot-reflexo-massage in diabetic patients. Method: A convenience sample of non-equivalent control group time series design was used. It provided foot care education to diabetic patients through small book for both group. For the experimental group, foot-reflexo-massage was taught by a researcher and research assistants. Analysis was done by Repeated Measured ANOVA. Result: There was significant increase in foot care knowledge, self care behavior, between the experimental group and the control group over three different times. There was significant in skin temperature and pulse of foot over three different times and interaction by groups or over time, but there was no significant difference between groups. There was no significant difference in blood flow volume and capillary filling time over three different times, between groups, but there was interaction by groups or over time. But there was significant difference in discrimination in change of dosalis pedis artery blood flow. Conclusion: Findings indicate that this study may contribute to develop nursing intervention for foot care of diabetic patients.

Do-It-Yourself (DIY) manufacture of a Nano-LC MALDI spotter robot using 3D printing technology

  • Lee, Jae-ung;Oh, Han Bin
    • 분석과학
    • /
    • 제30권4호
    • /
    • pp.167-173
    • /
    • 2017
  • In the era of the forth Industrial Revolution, open source code and open source hardware have gained much attention. In particular, 3D printing technology is expanding into the realms of classical science, technology and our daily lives. Relatedly, in the present study, we demonstrate the manufacture of a nano-LC MALDI spotter robot using 3D printing technology. The parts of the spotter robot were either made using a 3D printer or purchased as 3D printer parts from the 3D printer online market, so that anyone can make the robot without a deep knowledge of engineering or electronics, i.e., DIY (do-it-yourself) product. In the nano-LC MALDI spotter, the nano-LC eluent and MALDI matrix were mixed in a T-union and discharged from the capillary outlet. The eluent and matrix mixture could be spotted onto the movable MALDI plate. The MALDI plate was designed to translate in a two-dimensional space (xy plane), which was enabled by the movements of two stepper motors. In the paper, all computer-aided design (CAD) files for the parts and operation software are provided to help the reader manufacture their own spotter robot.

대체냉매를 이용한 가정용 냉장고의 시스템 특성에 관한 연구 (An investigation on the system characteristics of a refrigerator with alternative refrigerants)

  • 신진규;문춘근;윤정인
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.753-762
    • /
    • 1998
  • A domestic refrigerator is composed of many components such as a compressor, evaporator, capillary tube, and the cabinet which plays a great role on the cycle performance, even if it is not the basic component part in the cycle. Recently, the restriction policy on the energy-saving and environmentally friendly refrigerator is reinforced in our nation as well as developed countries. Therefore, in this paper, cycle simulations and experiments were carried out ito understand the characteristics of the cycle performance using CFC 12, HFC 134a, and HC 600a and to know how changes in UA(overall heat transfer coefficients$\times$ heat transfer area) of evaporator, the position displacement of compressor, and the rpm of fan in the freezing room which has influence on the cycle performance. The result shows that the quantitative values of simulation and experiment are not coincident, but their trend is similar. When HFC 134a and HC 600a were used without the change of design in refrigerator used CFC 12, the performance of system in HC 600a is 30% lower, and the case of HFC 134a is 10% lower than that of CFC 12 on freezing temperature.

  • PDF