Experimental Study on the Electrostatic Discharge in the HDD Spindle System Using Fluid Dynamic Bearings (유체동압베어링을 사용하는 하드디스크 드라이브 스핀들 시스템에서 발생하는 정전기 방전에 관한 실험적 연구)

  • Kang, Min-Gu;Jang, Gun-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.75-80
    • /
    • 2006
  • This paper introduces the mechanism of the ESD(electrostatic discharge) in the HDD spindle system using FDBs(fluid dynamic bearings). When a HDD(hard disk drive) spindle system is rotating, triboelectric charging occurs in the FDBs through the friction between the lubricant and the rotating shaft or between the lubricant and stationary sleeve. And this electrostatic charge is accumulated in the rotating parts of the HDD spindle system because they are insulated from the ground by the lubricant. This research shows experimentally that the behavior of electric charge and discharge in the FDB spindle system is the same as that of a capacitor. It also measures the electrostatic voltage difference between the rotating and stationary parts in the FDB spindle system due to the change of humidity, supporting load and motor speed. This research shows that the control of ESD is required in the HDD spindle system using FDBs, because the electrostatic charge accumulated in the FDB spindle system may cause the breakdown damage of the GMR head and data loss consequently.

Frequency Tracking of Resonance Frequency Variation of L-C Circuits for Wireless Energy Transmission to Medical Devices in Human Organs

  • Gimm, Yoon-Myoung;Ju, Young-Jun;Lee, Yu-Ri;Lee, Dong-Yeol;Wang, Jong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.298-303
    • /
    • 2011
  • A capsular endoscope (CE) for inspection of the large intestine requires a motor for backward navigation against the autonomous travel in the intestine. This study proposes an HF power system for generating a magnetic field and for delivering wireless power to the internal or implanted medical devices. The magnetic field is generated by a wound coil (L) around a wooden frame, and the current is driven to the coil through a resonating capacitor (C). The characteristics of the resonance frequency shifting of the L-C series circuit are analyzed. A stable magnetic field intensity in the field coil is maintained by a specially designed frequency tracking system that automatically follows the L-C resonance frequency. Testing confirmed that the oscillation system tracks well the parameter changes of the electric components caused by the operating conditions or environmental variations.

Analysis of Flicker Mitigation Effects using IEC Digital Flickermeter based on Matlab/Simulink Simulation (Matlab/Simulink 기반의 IEC 플리커미터를 이용한 플리커 저감효과 모의에 대한 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Kwon, Sae-Hyuk;Jang, Gil-Soo;Kang, Moon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.232-238
    • /
    • 2009
  • Flicker, also known as voltage fluctuation, is a newest problem of power quality issues, because it is caused by nonlinear loads such as electrical arc furnace and large-scale induction motor, which are country-widely used as the heavy industries of a country develop. An international standard, International Electrotechnical Commission (IEC) 61000-4-15, was published in 1997 and revised in 2003. With increasing concerns about flicker, its mitigation methods have been also studied. General countermeasures for flicker are divided into three categories: a) enhancing the capacity of supplying system, b) Series elements including series reactor and series capacitor and c) power electronic devices including static VAR compensator (SVC) and static synchronous compensator (STATCOM). This paper introduces how to mitigate the voltage flicker at the point of common coupling (PCC) and presents how to simulate and compare the flicker alleviating effects by each mitigation method, using IEC flickermeter based on the Matlab/Simulink program.

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Direct Instantaneous Torque Control of SRM using 4-level Converter (4-레벨 콘버터를 이용한 SRM의 순시 토오크 제어 기법)

  • Lee, Dong-Hee;Lee, Sang-Hun;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • This paper presents a direct instantaneous torque control (DITC) of Switched Reluctance Motor (SRM) with a novel 4-level converter to develop a uniform torque and to improve a dynamic performance. The DITC method can reduce a high torque ripple of SRM. Drive efficiency and dynamic performance with conventional drive are low due to a slow excitation current build-up. Since the 4-level converter can obtain an addition boosted voltage to have a fast excitation and demagnetization, it can Improve dynamic performance and efficiency easily. To apply the DITC technique to a 4-level converter, a novel control scheme is presented according to the operating modes. Additionally, selection of capacitances of boosted capacitor and efficiency improvement of 4-level converter are analyzed. At last, the validity of proposed method is verified by some computer simulations md comparative experiments.

Performance of Multi-level Inverter for High-Speed SR Drive (SRM의 고속운전을 위한 새로운 멀티레벨 인버터의 구동특성)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • In this paper, a novel multi-level inverter for low cost high speed switched reluctance(SR) drive is proposed. The proposed multi-level converter has reduced number of power switches and diodes than that of a conventional asymmetric converter for SRM and smaller voltage rating of the dump capacitor comparing with energy efficient c-dump converter. It can supply five operating modes that is boosted, DC-link, zero, negative bias and negative boosted voltage. The proposed multi-level converter has fast excitation and demagnetization modes of phase current, so dynamic response can be achieved. The proposed multi-level converter is verified by computer simulation and experimental results.

Estimation of ESR in the DC-Link Capacitors of AC Motor Drive Systems with a Front-End Diode Rectifier

  • Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.411-418
    • /
    • 2015
  • In this paper, a new method for the online estimation of equivalent series resistances (ESR) of the DC-link capacitors in induction machine (IM) drive systems with a front-end diode rectifier is proposed, where the ESR estimation is conducted during the regenerative operating mode of the induction machine. In the first place, a regulated AC current component is injected into the q-axis current component of the induction machine, which induces the current and voltage ripple components in the DC-link. By processing these AC signals through digital filters, the ESR can be estimated by a recursive least squares (RLS) algorithm. To acquire the AC voltage across the ESR, the DC-link voltage needs to be measured at a double sampling frequency. In addition, the ESR current is simply reconstructed from the stator currents and switching states of the inverter. Experimental results have shown that the estimation error of the ESR is about 1.2%, which is quite acceptable for condition monitoring of the capacitor.

Experiental Study on the Electrostatic Discharge in the HDD Spindle System Using Fluid Dynamic Bearings (유체동압베어링을 사용하는 하드 디스크 드라이브 스핀들 시스템에서 발생하는 정전기 방전에 관한 실험적 연구)

  • Kang, Min-Gu;Jang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.318-323
    • /
    • 2005
  • This paper introduces the mechanism of the ESD (Electrostatic discharge) in the HDD spindle system using FDBs (Fluid Dynamic Bearings). When a HDD (Hard Disk Drive) spindle system is rotating, triboelectric charging occurs in the FDBs through the friction of the lubricant between the rotating shaft and stationary sleeve. And this electrostatic charge is accumulated in the rotating part of the HDD spindle system because it is insulated from the ground by the lubricant. This research shows experimentally that the behavior of electric charge and discharge in the FDB spindle system is the same as that of a capacitor. It also measures the electrostatic charge and discharge of the FDB spindle system due to the chanse of humidity, supporting load and motor speed. This research shows that the control of ESD is required in the HDD spindle system using FDBs, because the electrostatic charge accumulated in the FDB spindle system may cause the breakdown damage of the GMR head and data loss consequently.

  • PDF

Analysis and Control of NPC-3L Inverter Fed Dual Three-Phase PMSM Drives Considering their Asymmetric Factors

  • Chen, Jian;Wang, Zheng;Wang, Yibo;Cheng, Ming
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1500-1511
    • /
    • 2017
  • The purpose of this paper is to study a high-performance control scheme for neutral-point-clamping three-level (NPC-3L) inverter fed dual three-phase permanent magnet synchronous motor (PMSM) drives by considering some asymmetric factors such as the non-identical parameters in phase windings. To implement this, the system model is analyzed for dual three-phase PMSM drives with asymmetric factors based on the vector space decomposition (VSD) principle. Based on the equivalent circuits, PI controllers with feedforward compensation are used in the d-q subspace for regulating torque, where the cut-off frequency of the PI controllers are set at the twice the fundamental frequency for compensating both the additional DC component and the second order component caused by asymmetry. Meanwhile, proportional resonant (PR) controllers are proposed in the x-y subspace for suppressing the possible unbalanced currents in the phase windings. A dual three-phase space vector modulation (DT-SVM) is designed for the drive, and the balancing factor is designed based on the numerical fitting surface for balancing the DC link capacitor voltages. Experimental results are given to demonstrate the validity of the theoretical analysis and the proposed control scheme.

Thermo-Mechanical Reliability of Lead-Free Surface Mount Assemblies for Auto-Mobile Application (무연 솔더가 적용된 자동차 전장부품 접합부의 열적.기계적 신뢰성 평가)

  • Ha, Sang-Su;Kim, Jong-Woong;Chae, Jong-Hyuck;Moon, Won-Chul;Hong, Tae-Hwan;Yoo, Choong-Sik;Moon, Jeong-Hoon;Jung, Seung-Boo
    • Journal of Welding and Joining
    • /
    • v.24 no.6
    • /
    • pp.21-27
    • /
    • 2006
  • This study was focused on the evaluation of the thermo-mechanical board-level reliability of Pb-bearing and Pb-free surface mount assemblies. The composition of Pb-bearing solder was a typical Sn-37Pb and that of Pb-free solder used in this study was a representative Sn-3.0Ag-0.5Cu in mass %. Thermal shock test was chosen for the reliability evaluation of the solder joints. Typical $Cu_6Sn_5$ intermetallic compound (IMC) layer was formed between both solders and Cu lead frame at the as-reflowed state, while a layer of $Cu_3Sn$ was additionally formed between the $Cu_6Sn_5$ and Cu lead frame during the thermal shock testing. Thickness of the IMC layers increased with increasing thermal shock cycles, and this is very similar result with that of isothermal aging study of solder joints. Shear test of the multi layer ceramic capacitor(MLCC) joints was also performed to investigate the degradation of mechanical bonding strength of solder joints during the thermal shock testing. Failure mode of the joints after shear testing revealed that the degradation was mainly due to the excessive growth of the IMC layers during the thermal shock testing.