• Title/Summary/Keyword: cantilever testing

Search Result 60, Processing Time 0.026 seconds

An Experimental Study on the Free Vibration of the Cantilever Composite Rectangular Plates with Point Supports (점지지된 복합재료 외팔 사각판의 자유진동에 관한 실험적 연구)

  • 이영신;최명환;류충현
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.623-631
    • /
    • 1998
  • The free vibration analyses of the isotropic and composite(CFRP, GFRP) rectangular plates with point supports at the free edge and middle position are performed. The natural frequencies and nodal patterns of plates with point supports are experimentally determined by impact testing using an impact hammer. To compare and verify these experimental results, the finite element analysis is also carried out. The effect of the point support position, the number of point supports, and the anisotropic parameters on the natural frequencies and nodal patterns of cantilevered rectangular plates are investigated.

  • PDF

Microcontroller based split mass resonant sensor for absolute and differential sensing

  • Uma, G.;Umapathy, M.;Kumar, K. Suneel;Suresh, K.;Josephine, A. Maria
    • Smart Structures and Systems
    • /
    • v.5 no.3
    • /
    • pp.279-290
    • /
    • 2009
  • Two degrees of freedom resonant systems are employed to improve the resonant property of resonant sensor, as compared to a single degree of freedom resonant system. This paper presents design, development and testing of two degrees of freedom resonant sensor. To measure absolute mass, cantilever shaped two different masses (smaller/absorber mass and bigger/drive mass) with identical resonant frequency are mechanically linked to form 2 - Degree-of-Freedom (DOF) resonator which exhibits higher amplitude of displacement at the smaller mass. The same concept is extended for measuring differential quantity, by having two bigger mass and one smaller mass. The main features of this work are the 3 - DOF resonator for differential detection and the microcontroller based closed loop electronics for resonant sensor with piezoelectric sensing and excitation. The advantage of using microcontroller is that the method can be easily extended for any range of measurand.

Comparative Study on the Failure of Polymer/Roughened Metal Interfaces under Mode-I Loading II: Adhesion Model (인장하중하에서의 고분자/거친금속 계면의 파손에 대한 비교연구 II: 접착모델)

  • Lee Ho-Young;Kim Sung-Ryong
    • Korean Journal of Materials Research
    • /
    • v.15 no.1
    • /
    • pp.6-13
    • /
    • 2005
  • Copper based leadframe sheets were immersed in two kinds of hot alkaline solutions to form brown-oxide or blackoxide layer on the surface. The oxide-coated leadframe sheets were molded with epoxy molding compound (EMC). After post mold curing, the oxide-coated EMC-leadframe joints were machined to form sandwiched double-cantilever beam (SDCB) specimens. The SDCB specimens were used to measure the fracture toughness of the EMC/leadframe interfaces under quasi-Mode I loading conditions. After fracture toughness testing, the fracture surface were analyzed by various equipment to investigate failure path. An adhesion model was suggested to explain the failure path formation. The adhesion model is based on the strengthening mechanism of fiber-reinforced composite. The present paper deals with the introduction of the adhesion model. The explanation of the failure path with the proposed adhesion model was introduced in the companion paper.

Free Vibration Cantilevered Composite Rectangular Plates with Point Supports (점지지된 복합재료 외팔 사각판의 자유진동)

  • 이영신;최명환;류충현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.414-419
    • /
    • 1997
  • The free vibration analysis of cantilever CFRP and GFRP composite rectangular plates with point supports at the free edge and interior position is performed. The natural frequencies and mode shapes of plates are experimentally determined by impact testing using an impact hammer. To compare and verify these experimental results, the finite element analysis is also carried out and the non-dimensional frequency parameters are compared with FE analysis results. The effects of the number and location of the point support on the frequencies are examined. In the experimental results, it is found that a significant increase in frequencies occurs when the point supports are added on certain parts of plates.

  • PDF

Behavior of steel storage pallet racking connection - A review

  • Chen, Chulin;Shi, Lei;Shariati, Mahdi;Toghroli, Ali;Mohamad, Edy Tonnizam;Bui, Dieu Tien;Khorami, Majid
    • Steel and Composite Structures
    • /
    • v.30 no.5
    • /
    • pp.457-469
    • /
    • 2019
  • Steel pallet racking industry has globally used from the industrial revolution and has deeply evolved from hot-rolled profile into cold-formed profile to raise the optimization in engineering field. Nowadays, some studies regarding cold-formed steel profile have been performed, but fewer studies in terms of cold-formed pallet racking specifically in connection due to the semi-rigid behavior by lug-hooked into the upright have been conducted. The objective of this study is to review the related literature on steel storage racking connection behavior.

Design, Fabricaiton and Testing of a Piezoresistive Cantilever-Beam Microaccelerometer for Automotive Airbag Applications (에어백용 압저항형 외팔보 미소 가속도계의 설계, 제작 및 시험)

  • Ko, Jong-Soo;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.408-413
    • /
    • 1996
  • A self-diagnostic, air-damped, piezoresitive, cantilever-beam microaccelerometer has been designed, fabricated and tested for applications to automotive electronic airbag systems. A skew-symmetric proof-mass has been designed for self-diagnostic capability and zero transverse sensitivity. Two kinds of multi-step anisotropic etching processes are developed for beam thickness control and fillet-rounding formation, UV-curing paste has been used for sillicon-to-glass bounding. The resonant frequency of 2.07kHz has been measured from the fabricated devices. The sensitivity of 195 $\mu{V}$/g is obtained with a nonlinearity of 4% over $\pm$50g ranges. Flat amplitude response and frequency-proportional phase response have been obserbed, It is shown that the design and fabricaiton methods developed in the present study yield a simple, practical and effective mean for improving the performance, reliability as well as the reproducibility of the accelerometers.

Developing Tuned Mass Damper of Adjustable Damping Type to Control the Vibrations of Medical Robots (의료용 로봇의 미진동제어를 위한 가변감쇠형 동조질량감쇠기 기술 개발)

  • Cha, WoonYong;Chun, ChongKeun;Park, SangGon;Han, HyunHee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.706-715
    • /
    • 2014
  • Recently, the medical community has been enthusiastically welcoming robots that are able to provide high-quality medical services across the board, including assisting the surgeons during surgeries. In response, many higher education institutions and research facilities started to conduct various experiments and studies about these robots. During such research, it was discovered that the arm of one particular robot type that is being developed to assist surgeries are prone to vibrate even from the weakest impact, in addition to other residual vibration problems. We attempted to reduce such dynamic response by using a MF-TMD that is produced by adding magnetic fluid to ECD. We verified the MF-TMD's performance by testing it within various frequency bands and attenuations. We then designed a cantilever that was structurally similar to the robot's arm. We attached the MF-TMD to this cantilever and conducted a pilot experiment, which validated our hypothesis that MF-TMD will reduce the robot arm's vibrations through its optimal damping ratio. Henceforth, we attached the MF-TMD to the robot arm in question and conducted a performance experiment in which we tuned the MF-TMD's frequency and damping factor to its optimal level and measured the vibrations of the arm. The experiment demonstrated that the vibrations that occurred whenever the arms rotated were significantly reduced.

Design for Improving the Loss Factor of Composite with Sandwich Structure (샌드위치 구조를 가지는 복합재의 손실계수 향상을 위한 설계)

  • Lee, C. M.;Jeon, G.S.;Kang, D.S.;Kim, B.J.;Kim, J.H.;Kang, M.H.;Seo, Y.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.235-241
    • /
    • 2016
  • Underwater weapon system is required to structurally strong material, since as it is directly exposed to external shock. It should also be using the lightweight material in order to take advantage of buoyancy. Composite materials meet these requirements simultaneously. Particularly in the case of submarine, composite materials are widely used. It is important to have a high strength enough to be able to withstand external shock, but it is also important to attenuate it. In a method for the shock damping, viscoelastic damping materials are inserted between the high strength composite material as a sandwich structure. Shock attenuation can be evaluated in the loss factor. In ASTM(American Society of Testing Materials), evaluation method of the loss factor of cantilever specimens is specified. In this paper, mode tests of the cantilever are performed by the ASTM standard, in order to calculate the loss factor of the viscoelastic damping material by the specified expression. Further, for verifying of the calculated loss factor, mode test of compound beams is carried out. In addition, the characteristics of the material were analyzed the effect on the loss factor.

A Study on the Micro-fracture Behavior of the MEMS Material at Elevated Temperature (고온용 MEMS 재료의 마이크로 파괴거동에 관한 연구)

  • Woo, Byung-Hoon;Bae, Chang-Won;Moon, Kyong-Man;Bae, Sung-Yeol;Higo, Yakichi;Kim, Yun-Hae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.5
    • /
    • pp.550-555
    • /
    • 2007
  • The effective fracture toughness testing of materials intended for application in Micro Electro Mechanical Systems (MEMS) devices is required in order to improve understanding of how micro sized material used in device may be expected to perform upon the micro scale. ${\gamma}$-TiAl based materials are being considered for application in MEMS devices at elevated temperatures. Especially, in Alloy 4, both ${\alpha}_2$ and ${\gamma}$ lamellae were altered markedly in 3,000 h, $700^{\circ}C$ exposure. Parallel decomposition of coarse ${\alpha}_2$ into bunches of very fine (${\alpha}_2+{\gamma}$) lamellae. Parallel decomposition of coarse ${\alpha}_2$ into bunches of very fine (${\alpha}_2+{\gamma}$) lamellae. The materials were examined 2 types Alloy 4 on heat exposed specimen($700^{\circ}C$, 3,000 h) and no heat exposed one. Micro sized cantilever beams were prepared mechanical polishing on both side at $25{\sim}30{\mu}m$ and electro final stage polishing to observe lamellar orientation of same colony with EBSD (Electron Backscatter Diffraction Pattern). Through lamellar orientation as inter-lamellae or trans-lamellae, Cantilever beam was fabricated with Focused Ion Beam(FIB). The directional behavior of the lamellar structure was important property in single material, because of the effects of the different processing method and variations in properties according to lamellar orientation. In MEMS application, it is first necessary to have a reliable understanding of the manufacturing methods to be used to produce micro structure.

Evaluation of Adhesive Properties in Polymeric Thin Film by Ultrasonic Atomic Force Microscopy (UAFM을 이용한 폴리머 박막의 접합 특성 평가)

  • Kwak, Dong-Ryul;Park, Tae-Sung;Park, Ik-Keun;Miyasaka, Chiaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.142-148
    • /
    • 2012
  • This study presents the assessment results of adhesive properties on the interface between a silicon wafer and nano-scale polymer thin film pattern through UAFM images by using the contact resonance frequency of the cantilever. For the experiment, we varied surface treatment processes for the silicon wafer and fabricated a 300nm polymer thin film pattern through lithography. Images from the optical microscope were used to compare the produced test specimens for adhesive condition and the critical load value from the nano scratch test was used to verify the adhesive condition of the nano pattern. Each test specimen resulted in a $1{\mu}m{\times}1{\mu}m$ surface image and subsurface adhesive image. Adhesive condition was evaluated by image contrast differences on the interface according to the changing amplitudes and phases of contact resonance frequency.