• Title/Summary/Keyword: cancer diagnosis

Search Result 2,862, Processing Time 0.037 seconds

Assessment of Damages for Non-pecuniary Loss and Compensation for Damages in Medical Accidents - Overview for Cases of Medical Injury Relief in Korea Comsumer Agency - (의료사고의 손해배상과 위자료 산정 -한국소비자원 의료피해구제 사례들의 일별-)

  • Kim, Kyoung Reay;Ahn, Bup-Young
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.2
    • /
    • pp.179-214
    • /
    • 2012
  • There are two opinions on the legal characteristics of damages for non-pecuniary loss, a private sanctions theory and complementary function of damages for non-pecuniary loss, briefly. There is a close connection between the legal characteristics and the function of damages for non-pecuniary loss. The functions of damages for non-pecuniary loss are consist of satisfaction, prevention( sanctions) and complementation. Several cases of medical injury relief reported to Korea Comsumer Agency are categorized as follows, 1) cases of death after having an operation, 2) diagnosed with disability after a medical accident, 3) extended damages happening related to delayed diagnosis, 4) et cetera(a plastic surgery, a treatment with oriental medicine), and the damages for non-pecuniary loss in respect to each cases are examined. In the case of occurring death or disability, Korea Comsumer Agency has set up guidelines for assessment of damages for non-pecuniary loss by classifying into major and collateral violation for a duty of care. Furthermore, the damages for non-pecuniary loss in the case of all sorts of cancers, are assessed in accordance with the degree of responsibility subsequent to dividing cancer into good and poor prognosis. When it comes to a complementary function of damages for non-pecuniary loss in the actual work, it is hard to assess the damages as it is difficult to objectify non-pecuniary loss, such as emotional distress. Though compensation for damages is major legal characteristics of consolation money, preventing a damage(private sanctions) through consolation for a victim or sanctions against an assailant also has great significance. Therefore, it is necessary to approach flexibly for mutual agreement by considering specialty( concrete facts) of individual issue thoroughly. If considering this aging society that limits the possible age for work to 60 years old, it is needed to have a complementary function of consolation money in mind not to make it less meaningful for victims due to small sum of consolation money.

  • PDF

Review of Allowable Condition of the Discretionary not Covered Service (임의비급여 허용요건에 관한 검토)

  • Park, Tae-Shin
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.2
    • /
    • pp.11-38
    • /
    • 2012
  • The Supreme Court stand in the position in specific lawsuit that it doesn't allow the discretionary not covered service, but recently in revocation suit of fine disposal that is imposed on medical fee of leukemia patient, it altered the existing adjudgement and admitted the discretionary not covered service exceptionally. It put forward the allowable condition roughly in that case. According as this alteration, it has become more important to embody the allowance conditions of exceptions. The Supreme Court presented three things, which are procedural condition, medical condition and subscriber's agreement. Concerning procedural condition, several present conciliation procedures are as follows: medical care benefit arret request, relative value conciliation etc, prior request on anti-cancer drug among chemicals which exceed acceptance criteria, request of non benefit object on common drugs. To be granted the existence of those system, there should be no obstacle to use that. Even if it were so, we should take circumstances into consideration; individual situation is unescapable concerning substance and urgency of the discretionary not covered service, process of the procedure, time required etc. Regarding medical condition, safety and effectiveness will be verified through evaluation procedures of new medical skill. About the necessity, the Supreme Court made clear through a sentence that it allow the discretionary not covered service, in case that needs to treat a patient out of the standard of medical benefit. Strict interpretation is right and it answer the purpose of the sentence that the supreme court permit the discretionary not covered service, exceptionally. We need to differentiate medical necessity and medical validity. Subscriber's agreement should holds true if it entails full explanation, and if it is preliminary, explicit and individual. On this account, it should be difficult to admit that someone agree effectively when he call for the affirmation that he is recipient of medical care. Reasonable expense needs to be a part of review whether the agreement is valid. Meanwhile If we adjust system of medical expense and eventually reorganize a fee for consultation payment system (Fee-for-service controlled by item to DRG (Diagnosis Related Groups)), controversial area of the discretionary not covered service will be decreased and that will guarantee the discretion of the doctor.

  • PDF

Detection of Hepatitis B Virus Using Micro-PCR and Real-Time PCR Methods (Micro-PCR과 Real-Time PCR을 이용한 B형 간염 바이러스 검출)

  • Kang, Won;Park, Sang-Bum;Nam, Youn-Hyoung;An, Young-Chang;Lee, Sang-Hyun;Jang, Won-Cheoul;Park, Su-Min;Kim, Jong-Wan;Chong, Song-Chun
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • Hepatitis B is a serious public health problem leading to chronic infection and liver cancer. Quantitation of circulating hepatitis B virus (HBV) is important for monitoring disease progression and for assessing the response to antiviral therapy. In this study, by using Real-Time PCR and novel Micro-PCR assay method, we measured HBV concentration in the clinical sample. A total of 120 serum samples from patients with HBV infection collected was in Dankook university hospital to compare the detection limit, sensitivity, specificity and reproducibility of the two assay methods. These findings of this study suggest that Micro-PCR and Real-Time PCR assay methods are comparable to each other in there detection limit, sensitivity, and reproducibility for HBV DNA quantitation. However, Micro-PCR assay is more efficient than Real-Time PCR method, because Real-Time PCR is not so time - consuming, technically easy and need to reagent of a small quantity. It will be useful for rapid and reliable clinical diagnosis of HBV in many countries.

Recent Trends in Photodynamic Therapy Using Upconversion Nanoparticles (업컨버전 나노입자를 이용한 광역학치료 연구 동향)

  • Im, Se Jin;Lee, Song Yeul;Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.138-146
    • /
    • 2018
  • Photodynamic therapy (PDT) is a great potential approach for the localized tumor removal with fewer metastatic potentials and side effects in treating the disease. In the treatment process, a photosensitizer (PS) that absorbs a light energy to generate reactive oxygen is essential. In general, a visible light is used as a light source of PDT, so that side effects from the light source are inevitable. For this reason, upconversion nanoparticles (UCNPs) using near-infrared (NIR) as an excitation source are attracting attention in the field of disease diagnosis and treatment. UCNPs have the low cytotoxicity and phototoxicity, and also advantages such as deep tissue penetration and low background autofluorescence. For PDT, UCNPs should be combined with a PS which absorbs the light energy from UCNPs and transfers it to the surrounding oxygen to produce reactive oxygen. In addition, the therapeutic efficacy can be improved by modifying nanoparticle surfaces, adding anti-cancer drugs, or combining with photothermal therapy (PTT). In this review, we summarize the recent research to improve the efficiency of PDT using UCNPs.

Video-assisted Thoracoscopy in the Treatment of Multi Loculated Pleural Effusion and Empyema (다방성 흉막수 및 노흉 환자에서 비디오 흉강경의 치료)

  • 김영진
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.160-165
    • /
    • 2004
  • Successful treatment of multi-loculated pleural effusion or thoracic empyema requires effective drainage and definitive diagnosis of causative organism. The purpose of this study was to assess the efficacy of the video-assisted thoracoscopic surgery in the management of thoracic empyema or multi-loculated pleural effusion after chest tube drainage treatment had failed. Material and Method: Between April 2000 and July 2002, 20 patients with thoracic empyema or multi-loculated pleural effusion that failed to chest tube drainage or other procedures who underwent an operation. All patients were assessed by chest-computed tomogram and underwent video assisted thoracoscopic drainage, debridement, biopsy and irrigation of pleural cavity. Result: In 18 cases (90%), underwent successful video-assisted thoracoscopic surgery. In 2 cases, decortications by mini-thoracotomy were necessary. The ratio of sex was 4 : 1 (16 male: 4 female), mean age was 48.9 years old (range, 17∼72 years), mean duration of postoperative chest tube placement was 8.2 days (range, 4∼22 days), mean postoperative hospital stay was 15.2 days (range, 7∼33 days). Causative disease was tuberculosis, pneumonia, trauma and metastatic breast cancer, There were no major postoperative complications. Symptoms improved in all patients and were discharged with OPD follow up. Conclusion: In an early organizing phase of empyema or multi loculated pleural effusion, video-assisted thoracoscopic drainage and debridement are safe and suitable treatment.

The Optimal Time of Fiberoptic Bronchoscopy to Locate the Bleeding Site in Patients with Hemoptysis (객혈의 병소를 확인하기 위한 굴곡성 기관지경 검사의 시행시기)

  • Cheon, Ho-Gi;Kim, Jung-Baek;Yoon, Ki-Heon;Yoo, Jee-Hong;Kang, Hong-Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.20-25
    • /
    • 1994
  • Background: Hemoptysis is a common clinical symptom, responsible for 11% of admission to the hospital chest service. Correct diagnosis, accurate localization of the bleeding source and proper management are imperative to reduce the risk of massive hemoptysis. We performed the study to define the optimal time of fiberoptic bronchoscopy in 63 patients with hemoptysis admitted to Kyung Hee University Hospital between Aug 1989 and Aug 1992. Methods: Retrospective analysis of medical records concerning the cause, amount, duration of hemoptysis and the timing of fiberoptic bronchoscopy in 63(M:F=36:27) patients. Results: 1) The main causes of hemoptysis were pulmonary tuberculosis(52.4%) bronchiectasis(27.0%) and lung cancer(11.1%). 2) The bleeding sites were localized in 26 patients(41.3%). 3) The rates of localization of bleeding site were not related to the amount and duration of hemoptysis. 4) The rates of localization of bleeding site were 61.8%(21/34) during hemoptysis, 18.2%(22) within 24hr after resolution of hemoptysis, 14.3%(1/7) thereafter. Conclusion : Early bronchoscopy, especially during hemoptysis may show higher rates of successful localization than delayed bronchoscopy.

  • PDF

A Basic Study on the Differential Diagnostic System of Laryngeal Diseases using Hierarchical Neural Networks (다단계 신경회로망을 이용한 후두질환 감별진단 시스템의 개발)

  • 전계록;김기련;권순복;예수영;이승진;왕수건
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.197-205
    • /
    • 2002
  • The objectives of this Paper is to implement a diagnostic classifier of differential laryngeal diseases from acoustic signals acquired in a noisy room. For this Purpose, the voice signals of the vowel /a/ were collected from Patients in a soundproof chamber and got mixed with noise. Then, the acoustic Parameters were analyzed, and hierarchical neural networks were applied to the data classification. The classifier had a structure of five-step hierarchical neural networks. The first neural network classified the group into normal and benign or malign laryngeal disease cases. The second network classified the group into normal or benign laryngeal disease cases The following network distinguished polyp. nodule. Palsy from the benign laryngeal cases. Glottic cancer cases were discriminated into T1, T2. T3, T4 by the fourth and fifth networks All the neural networks were based on multilayer perceptron model which classified non-linear Patterns effectively and learned by an error back-propagation algorithm. We chose some acoustic Parameters for classification by investigating the distribution of laryngeal diseases and Pilot classification results of those Parameters derived from MDVP. The classifier was tested by using the chosen parameters to find the optimum ones. Then the networks were improved by including such Pre-Processing steps as linear and z-score transformation. Results showed that 90% of T1, 100% of T2-4 were correctly distinguished. On the other hand. 88.23% of vocal Polyps, 100% of normal cases. vocal nodules. and vocal cord Paralysis were classified from the data collected in a noisy room.

Preparation and characterization of the primary gas standards for isoprene (아이소프렌 일차표준가스의 제조 및 특성 평가)

  • Kim, Taesu;Kang, Chul-Ho;Kim, Yong Doo;Lee, Seungho;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.357-363
    • /
    • 2014
  • Isoprene is a one of the biogenic volatile organic compounds (BVOCs) and it is known as a source of the tropospheric ozone and formaldehyde. In addition, isoprene is a trace component of the exhaled breath and it is a potential biomarker for the diagnosis of diseases such as lung cancer. In these regards, isoprene gas standards are required for the accurate measurement of isoprene in air samples. To establish a standard for isoprene gas, gravimetric preparation and characterization of primary gas standards were studied. The primary gas standards were produced independently in 4 aluminum cylinders and concentrations were examined by GC-FID. As a result, the uncertainty of the gravimetric preparations including purity of the raw material was 0.01% and reproducibility of the preparation of independent 4 cylinders was 0.08%. The primary gas standards for isoprene showed 14 months of long-term stability. The relative expended uncertainty of 2.8% (95% of confidence level, k=1.96) was assigned to the certified value of 10 ${\mu}mol$/mol level of isoprene based on the quantitative evaluation of the purity, weighing, reproducibility, adsorption and long-term stability.

Diamond-Blackfan anemia: long-term follow-up of six cases (Diamond-Blackfan 빈혈: 6예 장기간 추적관찰보고)

  • Son, Young Jun;Baek, Hee Jo;Kook, Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1211-1216
    • /
    • 2008
  • Purpose : Diamond-Blackfan anemia (DBA) is a rare heterogeneous genetic disorder of infancy and early childhood. It is characterized by red cell aplasia, congenital anomalies, and a predisposition to cancer. Corticosteroids and red cell transfusions are the mainstays of therapy. We describe our experience of 6 cases of DBA that were encountered over a period of 16 years. Methods : Medical records of 6 patients diagnosed to have DBA and admitted to the Chonnam National University Hospital between 1992 and 2008 were retrospectively reviewed. Results : Three patients were males. The age at diagnosis ranged from 3 to 18 months (median, 5.5 months). Heart defects were observed in 4, polydactyly in 2, and strabismus in 1 patient. The median number of transfusions was 3 (range, 2-8). All patients responded to initial treatment with steroids and had a hemoglobin level ${\geq}9g/dL$ with a median of 12.5 days (range, 7-22 days). Three patients are currently not receiving steroid therapy. A minimum dose of oral prednisolone (<5 mg per day) was required to maintain hemoglobin ${\geq}9mg/dL$ in 3 cases. Red cell transfusion was infrequently required in 1 patient. In the median follow-up of 14 years, there was no development of malignancy. No significant side effects of steroids were found, except for short stature in 2. Conclusion : The majority of DBA patients achieved complete response and under maintenance therapy with low dose of steroids. Close observation is needed to monitor steroid side effects, cardiac function, and development of malignancy. A nation-wide survey is necessary to further characterize this rare disease in Korean children.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.