• Title/Summary/Keyword: can materials

Search Result 20,893, Processing Time 0.053 seconds

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Synthesis and Evaluation of $2-[^{18}F]Fluoro-A85380$, a Radioligand for ${\alpha}_4{\beta}_2$ Nicotinic Acetylcholine Receptor Imaging (${\alpha}_4{\beta}_2$ 니코틴성 아세틸콜린 수용체 영상 방사성리간드 $2-[^{18}F]fluoro-A85380$의 합성 및 평가)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Sang-Eun;Hwang, Sae-Hwan;Paik, Jin-Young;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.261-270
    • /
    • 2002
  • Purpose: Nicotinic acetylcholine receptors (nAChRs), which mediate excitatory neurotransmission, are known to participate in various neurophysiological functions. Severe losses of nAChRs have been noted in Alzheimer's and Parkinson's diseases. Therefore, noninvasive and quantitative imaging of nAChRs would offer a better understanding on the function of these receptors. In this study, $2-[^{18}F]fluoro-A85380\;([^{18}F]1)$, an ${\alpha}_4{\beta}_2$ nAChRs radioligand, was prepared using one HPLC purification and evaluated in mouse brain, and the results were compared with those in the literature. Materials and Methods: $[^{18}F]1$ was prepared by $[^{18}F]$fluorination of the iodo precursor followed by acidic deprotection and then purified by HPLC. Tissue distribution studies were performed in mouse brain at the indicated time points and the result was expressed as %ID/g. Inhibition studies were also carried out with pretreatment of various ligands. Results: One HPLC purification method gave the desired product in 15-20% radiochemical yield and with high specific activity ($38-55GBq/{\mu}mol$). Tissue distribution studies showed that $[^{18}F]1$ specifically labeled nAChRs in mouse brain with a high thalamus to cerebellum uptake ratio (13.8 at 90 min). Inhibition studios demonstrated selective binding of $[^{18}F]1$ to nAChRs, blocking the uptake of the $[^{18}F]1$ in nAChR-rich legions by selective ligands such as cytisine and nicotine which are well-known nAChRs agonists. Conclusion: This study demonstrated that the $[^{18}F]1$ produced by the method using one HPLC purification gave the results similar to those reported in the literature. Therefore, this synthetic method can be readily applied to the routine preparation of $[^{18}F]1$, a PET radioligand for ${\alpha}_4{\beta}_2$ nAChRs imaging.

Is the Renal Uptake of $^{99m}Tc$-DMSA Decreased in Microalbuminuric Diabetic Patient? (미세 단백뇨기의 당뇨병 환자에서 $^{99m}Tc$-DMSA 신섭취율은 감소하는가?)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.398-404
    • /
    • 1999
  • Purpose: Diabetic nephropathy is the most common cause of end stage renal disease and the incidence is progressively increasing. The aim of this study was to investigate the differences of $^{99m}Tc$-DMSA renal uptake among diabetic patients with normoalbuminuria, microalbuminuria and overt proteinuria, and then to determine the clinical usefulness of $^{99m}Tc$-DMSA in predicting early diabetic nephropathy Materials and Methods: $^{99m}Tc$-DMSA scan was performed and a total renal uptake of $^{99m}Tc$-DMSA was measured in 145 diabetic patients. Patients were divided into 3 groups according to the amount of 24 hour urinary albumin excretion as Group I (normoalbuminuria, 74 cases), Group II (microalbuminuria, 39 cases), and Group III (overt proteinuria, 32 cases). The differences of $^{99m}Tc$-DMSA renal uptake among the 3 groups and the correlation between the renal uptake of $^{99m}Tc$-DMSA and other clinical parameters were analyzed. Results: The total renal uptake of $^{99m}Tc$-DMSA of Group II ($40.8{\pm}11.0%$) was significantly lower than that of Group I ($54.4{\pm}6.3%$, p<0.001). The uptake of Group III ($27.7{\pm}12.0%$) was significantly lower than those of both Group I and Group II (p<0.001). $^{99m}Tc$-DMSA total renal uptakes correlated negatively with serum creatinine level (r=-0.629, p<0.001) and positively correlated with creatinine clearance rate (r=0.102, p<0.001). Conclusion: $^{99m}Tc$-DMSA total renal uptake of diabetic patients with microalbuminuria was significantly decreased compared with that of patients of normoalbuminuria. Therefore, $^{99m}Tc$-DMSA scan can be used as a diagnostic study for early detection of the diabetic nephropathy.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Evaluation of Database Comparison Methods for 18F-FDG Brain PET/CT (18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2015
  • Purpose Various database comparison methods(DCM) are used for analyzing functional neuro-imaging. It is possible to statistically evaluate decreased or increased metabolism of abnormal patient's brain by comparing with asymptomatic controls in DCM. And results of DCM are additionally used for easily explaining defect region. The aim of this study was to evaluate usefulness of statistical parametric mapping(SPM) and scenium. Materials and Methods Data of 15 patients($62.02{\pm}15.03year$) underwent $^{18}F-FDG$ brain PET/CT were collected and analyzed. Biograph TruePoint 40 with TrueV, (Siemens) was used as a PET/CT scanner. Scenium(version 4.0) in Syngo.via(version VA30A) and SPM99 were applied for statistical evaluation. Consistency between PET reading and result of DCM were evaluated by 5 nuclear medicine physicians through a questionnaire survey. SUV and SD changes were evaluated by changing iteration, gaussian filter and matrix size in scenium. And average required time for generating result of SPM99 and scenium was compared by 3 medical technologists. Results Consistency from the result of SPM99 and scenium showed 84% and 92.4% compare to PET reading. When iteration 4, FWHM 8 and matrix size 168, SUV and SD were decreased by 0.59%, 8.73%, 4.69%, 20.38% and 0.88%, 8.25% respectively compare to routine parameter(iteration 8, FWHM 2 and matrix size 336) of scenium. Average required time of SPM99 and Scenium took 282 seconds and 116 seconds to generate result. Conclusion Results of SPM99 and Scenium showed high consistency compare to PET reading. Various parameters can be controled by user when using SPM. However, normal database needs to be acquired. And it takes significant amount of time and effort for the first set up. On the other hand, Scenium provides normal database even though modifiable parameters are limited. Therefore, more informations could be provided for brain PET/CT if properly understanding and selecting each DCM.

  • PDF

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF