• Title/Summary/Keyword: caliper

Search Result 245, Processing Time 0.023 seconds

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

The Influence of the Risk Factors and Nutritional Status on the Development of Pressure Sores for the Risk Patients in ICU (욕창발생위험요인과 영양상태가 중환자실 입원환자의 욕창발생에 미치는 영향 - 욕창발생위험집단을 중심으로 -)

  • Yang Young-Hee;Kim Won-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.280-292
    • /
    • 1998
  • Pressure sores are a serious concerns in that respect to increasing risk of medical complications and medical costs. Prevention and care of pressure sores is an essential area of nursing practice. The nurse at ICU should be more careful of maintaining the skin integrity of patients especially than at any other place. This study was conducted to determine if the risk facotrs of pressure sores and nutritional status of the patients at risk for pressure sores is related the occurance of pressure sore. The risk group refers the patients having the below 14 scores of the braden scale. The 100 subjects were recruited from the ICU ward at an university hospital in Choongnam. The parameters for nutritional status are the blood chemistry including plasma protein, albumin, hemoglobin and the anthropometric measurements consisting of weight, BMI, LBM, the proportion of body fat, body fluid and triceps skin fold using bioimpedence analizer and caliper. The results are as follows : 1. The subjects were 55 years and stayed 8 days on average. Of the 100 subjects, males were 61%, neurologic/neurosurgical diseases were 68% and the incidence of pressure sores was 17% mainly occuring within 3days after the admission. 2. The present paralysis(or paraplegia) and edema(arm, leg, trunk) were showed more significantly the subjects with pressure sores than those without pressure sores. 3. Regarding with the nutritional status, the subjects with pressure sores had significantly lower the weight, BMI, LBM, body fluid, albumin than the ones without pressure sores. This results were supported the reports of previous studies that the decreased weight and albumin could be the important predictors of pressure sores. Thereafter we should encourage these factors to be utilized in predicting pressure sores for a comprehensive assessment. Nurse should identify patients at risk of the development of pressure sores, assess their nutritional status and dietary intake at regular intervals.

  • PDF

Growth Response on the Euonymus fortunei 'Emelad' n 'Gold' as affected by Artificial Plantings Soil Properties during Dry Spring Season (봄철 건조기 용기형 벽면녹화에서 식재지반 조성에 따른 황금줄사철의 적응성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Park, Heon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1299-1305
    • /
    • 2014
  • For evaluating the effect of various artificial planting soil properties on the Euonymus fortunei 'Emelad'n Gold' growth, a container green wall system experiment was conducted in a wall of greenhouse at Konkuk University, Glocal campus. The experimental artificial planting grounds were prepared with different organic soil conditioner ratios (Control, $A_4O_1$, $A_2O_1$ and $A_1O_1$) and with drought tolerance and an ornamental value Euonymus fortunei 'Emelad'n Gold' was planted. The soil and plant characteristics were investigated from April to Jun 2010. The volumetric soil moisture contents were significantly increasing order as the amount of organic soil conditioner level increased in order to $A_1O_1$ > $A_2O_1$ > $A_4O_1$ > Control. At 4 treatment, soil chemical properties were inversely related to organic soil container ratios increase. The differences of root collar caliper, number of branch, and survival rate between the organic soil conditioner ratio were not significantly affected by organic soil conditioner. But, plant height, internode length, leaf length and leaf width were significantly shorter on plants planted $A_1O_1$ than plants planted other treatments. Therefore, Euonymus fortunei 'Emelad'n Gold' had good growth response regardless of organic soil conditioner ratio and the plant is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in artificial planting soil.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

  • Lima, Ana Paula Barbosa;Vitti, Rafael Pino;Amaral, Marina;Neves, Ana Christina Claro;Concilio, Lais Regiane da Silva
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.122-127
    • /
    • 2018
  • PURPOSE. This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (${\alpha}=.05$). RESULTS. The results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION. The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

Evaluation of alveolar crest bone loss via premolar bitewing radiographs: presentation of a new method

  • Safi, Yaser;Kadkhodazadeh, Mahdi;Safai, Pooria;Esmaeelinejad, Mohammad;Shamloo, Nafiseh
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.222-226
    • /
    • 2014
  • Purpose: This study aimed to assess the interdental bone level in premolar bitewing radiographs while retracting the cheeks. Methods: Seventy-two horizontal bone defects were created on dried mandibles and maxillae. The distance from the bone level to the cement-enamel junction of premolars was detected by a modified digital caliper (considered the gold standard). The reliability of all radiographs was assessed by intraclass correlation coefficient (ICC), and the validity was compared to the gold standard using the analysis of variance test. P-values less than 0.05 were considered statistically significant. Results: This study showed that the reliability of radiographs without a cheek simulator and with 0.16 second exposure time was significantly higher than that of the two other groups (ICC=0.96 compared to 0.93 and 0.88, respectively). The results from the radiographs without a cheek simulator and with 0.16 second exposure time were more similar to the gold standard measures than those of the two other groups, although the difference was not statistically significant. Conclusions: Retracting the buccal soft tissue plays an important role in increasing the accuracy of radiographs in detecting the interdental alveolar bone level and produces more accurate results than increasing the exposure time, although it does not have a significant role in reliability of results.

Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study (CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Hae-Young;Kim, Jung-Ae;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

Effects of Circuit Weight Training on Isokinetic Muscle Strength and Body Composition in elderly (서킷 웨이트트레이닝이 노인들의 등속성 근력과 신체구성에 미치는 영향)

  • Chang Ghung-Hoon;Jeong Dong-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.398-411
    • /
    • 2003
  • The purpose of this study was to investigate the effects of circuit weight training(CWT) on isokinetic muscle strength and body composition in elderly. The subjects who engaged in this experiment exercised at $40\%$ of 1-RM, 12 repetitions, followed by 15 sec as the subject moved to the each break training program which was consist of the circuit of 10 stations performed on 3 set a day, circuits 3 days a week during 10 weeks. The assessment of isokinetic factor was in concentric flexors and extensors of right and left knee joint. Tests were performed on the Cybex 770 Isokinetic Dynamometer and body composition were estimated the three parts of chest, abdomen and anterior thigh by using skinfold caliper, calculated the average and followed by Seri and Brozek way. Statistical analysis were performed using analysis of variance paired t-test, accepting level for all significant was above ${\alpha}=.05$ and ${\alpha}=.01$. Following is as a result of 10 weeks circuit weight training. 1. At the $60_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly(p<.01). 2. At the $180_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly(p<.01). 3. At the $60_{\circ}$ /sec, the right and left knee isokenetic concentric flexors and extensors average power increased significantly(p<.05, p<.01) and at the $180_{\circ}$ /sec, the right extensors didn't show any statistical significant. 4. At the $60_{\circ}$ /sec, the right and left knee Isokinetic concentric flexors and extensors total work increased significantly(p<.05, p<.01) but at the $180_{\circ}$ /sec right concentric flexors didn't show any statistical significant. 5. The body composition changed significantly(p<.01). These results suggest that 10 weeks circuit weight training increases the peak torque, average power, total work significantly and decreases the $\%$body fat significantly.

  • PDF

Will Prone Trunk Extension Affect Scapular and Thoracic Kinematics and Muscle Activities During Scapular Posterior Tilting Exercise in Subjects With Round Shoulder and Flexed Posture?

  • Shin, A-reum;Lee, Ji-hyun;Kim, Da-eun;Cynn, Heon-seock
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.1-8
    • /
    • 2018
  • Background: Round shoulder posture, results from excessive flexed posture of the thorax, is defined as a position of scapular protraction, anterior tipping, and downward rotation. However, previous studies have focused on only passive position of the thorax during scapular posterior tilting (SPT) and have not reported on SPT combined with correction of flexed posture. Objects: The aim of this study was to compare effects of SPT and SPT with prone trunk extension (SPT + PTE) on activities of the lower trapezius, serratus anterior, and thoracic erector spinae and degree of posture in subjects with round shoulder and flexed posture. Methods: Fifteen subjects with round shoulder and flexed posture were recruited. The caliper was used to measure the degree of round shoulder and flexed posture. Electromyography was performed to collect data of muscle activities. Paired t-test was used to compare two exercise (${\alpha}=.05$). Results: When SPT + PTE was applied, the degree of round shoulder posture (p=.001) and flexed posture (p=.039) significantly decreased compared with that when SPT was applied. The lower trapezius activity significantly increased in the SPT + PTE condition compared with that in the SPT condition (p=.026). There were no significant differences in serratus anterior activity between SPT + PTE and SPT. The thoracic erector spinae activity significantly increased in the SPT + PTE condition compared with that in the SPT condition (p=.014). Conclusion: SPT + PTE might be one of the effective methods to enhance activities of lower trapezius and thoracic erector spinae, and to reduce round shoulder posture and flexed posture in subjects with round shoulder and flexed posture.

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF