• 제목/요약/키워드: calibration factor

검색결과 434건 처리시간 0.029초

액체용 유량계교정시스템의 교정측정능력 평가 (CMC Evaluation of Flowmeter Calibration System for Liquid)

  • 이동근;김종섭;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.5-10
    • /
    • 2014
  • It is possible for the nation's largest flowmeter calibration system in K-water to calibrate flow rate up to $2,700m^3/h$ and diameter 800mm. However, the calibration and measurement capability of K-water's system is not satisfied in comparison with other developed countries. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the combined standard uncertainty has been improved $1.099{\times}10^{-3}$ to $2.332{\times}10^{-4}$. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).

충주댐 유역의 유출량에 대한 SWAT 모형의 예측 불확실성 분석 기법 비교 (Comparing Prediction Uncertainty Analysis Techniques of SWAT Simulated Streamflow Applied to Chungju Dam Watershed)

  • 조형경;박종윤;장철희;김성준
    • 한국수자원학회논문집
    • /
    • 제45권9호
    • /
    • pp.861-874
    • /
    • 2012
  • SWAT(Soil and Water Assessment Tool) 모형의 적용성 검증을 위해서는 매개변수 민감도 분석 및 검 보정, 예측 불확실성 분석을 필요로 한다. 최근 SWAT 모형의 불확실성을 분석하기 위한 다양한 기법들이 개발되었는데, 본 연구는 충주댐 유역(6,581.1 $km^2$)을대상으로유역출구점의 실측 일 유출량자료(1998~2003)를 바탕으로 SWAT 모형의 유출관련 매개변수에 대한 불확실성 분석을 실시하였다. 이때 사용된 분석 기법으로는 SUFI2 (Sequential Uncertainty FItting algorithm ver.2), GLUE(Generalized Likelihood Uncertainty Estimation), ParaSol (Parameter Solution) 등을 적용하였다. 이러한 기법은 모두 SWAT-CUP (SWAT-Calibration Uncertainty Program; Abbaspour et al., 2007) 모형에 탑재되어있으며, 모형의 결과로써 검 보정, 매개변수의 민감도 분석, 각종 목적 함수 및 불확실성의 범위 등이 자동으로 산출되므로 모형의 사용자가 불확실성 평가 기법의 분석 및 비교를 손쉽게 할 수 있다. 그 결과 대표적인 목적 함수인 결정 계수($R^2$; Legates and McCabe, 1999)와 NS (Nash and Sutcliffe, 1970) 모형효율은 모두 0.67에서 0.92 사이의 값을 나타내어 대체적으로 모의가 잘 이루어졌음을 알 수 있었다. 그러나 불확실성의 범위를 나타내는 지표인 p-factor 및 r-factor에서는 평가 기법 별로 그 차이가 확연하게 드러났다. 여기서 p-factor는 불확실성 범위에 실측치가 포함되는 비율이며, r-factor는 불확실성의 상대적인 범위로 각각 1과 0에 가까울수록 모의기법의 성능이 우수함을 의미한다. 세가지 알고리듬 중에서 SUFI2의 p-factor가 약 0.79로 가장 높게 나타났으며, ParaSol의 r-factor가 0.03으로 가장 작게 나타났다. 본 연구의 결과는 SWAT 모형을 이용한 수문 모의에서 수문분석에 따른 예측결과의 불확실성을 정량적으로 평가함으로서, 모형의 적용성 평가 및 모의결과의 신뢰성 확보에 근거자료로 활용이 가능할 것으로 판단된다.

Safety factor calibration for bridge concrete girders

  • Silva, Rita C.;Cremona, Christian
    • Structural Engineering and Mechanics
    • /
    • 제49권2호
    • /
    • pp.163-182
    • /
    • 2014
  • Safety factors proposed in codes CEB, B.A.E.L 91 and EUROCODE 1 cover a great number of uncertainties; making them inadequate for the assessment of existing structures. Suitable safety factors are established using a probabilistic assessment, once real dimensions, materials strength and existing structures deterioration mechanisms are taken into account. This paper presents a calibration method for safety factors using a typical set of RC bridges in France. It considers the principal stages of corrosion provoked by $CO_2$ and $Cl^-$ penetration and threshold indexes (${\beta}_0$) for existing structures. Reliability indexes are determined by the FORM method in the calibration method.

단지교정을 위한 빈평균방법과 최소자승법의 비교 (Comparison of Bin Averaging Method and Least Square Method for Site Calibration)

  • 유능수;남윤수;이정완;이명재
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.157-164
    • /
    • 2005
  • Two methods, the bin averaging method and least square method, are often used in calibrating wind turbine test sites. The objective of this work was to determine a better method to predict the wind speed at wind turbine installing point. The calibration was done at the test site on a complex terrain located in Daegwallyeong, Korea. It was performed for two different cases based on the IEC 61400-12 power performance measurement standard. The wind speeds averaged for 10 minutes ranged between 4 m/s and 16 m/s. The wind-direction bins of each meteorological mast were 10 degrees apart, and only the bins having data measured for more than 24 hours were employed for the test site calibration. For both cases, the two methods were found to yield almost same results which estimated real wind speed very closely.

  • PDF

철도교 상시계측시스템의 센서교정방안 연구 (A Study on Calibrations of health monitoring system installed in Railway bridge)

  • 이현석;이준석;최일윤;임명재
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.483-488
    • /
    • 2003
  • Calibration and gauge factor readjustment process made for the health monitoring system installed in the railway bridges is reviewed and some findings are explained in this study: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in details. Based on the regression results, new gauge factors are obtained from regression equation and another verification is made by performing another calibration again with new factors. From the second calibration, it was found that the suggested regression curves and their factors are appropriate and much better results are expected. Future work will be concentrated on the long-term analysis of the measurement data and on the database structures so that the assessment of the structure such as damage detection and remaining life estimation is possible.

  • PDF

The Development of a Wearable Prototype to Measure Clothing Pressure through Sensor Calibration Procedure

  • Jin, Heejae;Lee, Hyojeong
    • 한국의류학회지
    • /
    • 제46권5호
    • /
    • pp.827-835
    • /
    • 2022
  • Clothing pressure is considered the essential factor affecting the comfort of clothing, so it is crucial that it is measured precisely. The purpose of this study is to construct a prototype using the Adafruit Flora as the Arduino system, which can be used as a wearable framework for easy, low-cost, and precise clothing pressure measurement. The study also aims to determine how best to conduct the procedure of sensor calibration. To optimize the accuracy of the sensors, the calibration procedure was implemented using mathematical methods that combined polynomial and exponential regression in a hybrid approach. The prototype can easily measure clothing pressure even during active movements, as seen in the detection of stable signals. In addition, since the system was specifically proposed as a wearable patch that can be easily attached and removed as necessary, it can also be used to standardize the value of clothing pressure in each movement.

Bayesian hypothesis testing for homogeneity of coecients of variation in k Normal populationsy

  • Kang, Sang-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권1호
    • /
    • pp.163-172
    • /
    • 2010
  • In this paper, we deal with the problem for testing homogeneity of coecients of variation in several normal distributions. We propose Bayesian hypothesis testing procedures based on the Bayes factor under noninformative prior. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be dened up to a multiplicative constant. So we propose the objective Bayesian hypothesis testing procedures based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

레이더에 의한 개선된 강우강도와 면적 강우량의 실시간 추정 (Improvement of Radar Rainfall Intensity and Real-time Estimation of Areal Rainfall)

  • 정성화;김경익;김광섭
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.643-646
    • /
    • 2006
  • An operational calibration is applied to improve radar rainfall intensity using rainfall obtained from rain gauge. The method is applied under the assumption of the temporal continuity of rainfall, the rainfall intensity from rain gauge is linearly related to that from radar. The method is applied to the cases of typhoon and rain band using the reflectivity of CAPPI at 1.5km obtained from Jindo radar. The CAPPI is obtained by bilinear interpolation. For the two cases, the rainfall intensities obtained by operational calibration are very consistent with the ones by the rain gauges. The present study shows that the correlation between the rainfall intensity by operational calibration and rain gauges is better than the one between the rainfall intensity by M-P relationship and rain gauges. The correlation coefficients between the total rainfall intensity obtained by operational calibration and rain gauges in typhoon and rain band cases are 0.99 and 0.97, respectively. Areal rainfalls are estimated using the field of calibration factor interpolated by Barnes objective analysis. The method applied here shows an improvement in the areal rainfall estimation. For the cases of typhoon and rain band, the correlation between the areal rainfall by operational calibration and rain gauges is better than the one between the area rainfall by M-P relationship and rain gauges. The correlation coefficients between the areal rainfall obtained by operational calibration and rain gauges in typhoon and rain band cases are 0.97 and 0.84, respectively. The present study suggests that the operational calibration is very useful for the real-time estimation of rainfall intensity and areal rainfall.

  • PDF

2014~2015 연속가뭄을 고려한 SWAT 수질 매개변수 보정 (Calibration of Water Quality Parameters in SWAT Considering Continuous Drought Periods 2014~2015)

  • 김다래;이지완;정충길;김성준
    • 한국농공학회논문집
    • /
    • 제60권1호
    • /
    • pp.11-20
    • /
    • 2018
  • This study is to calibrate the SWAT (Soil and Water Assessment Tool) water quality of SS (Suspended Solid), T-P (Total Phosphorus), and T-N (Total Nitrogen) by focusing on 2014~2015 drought periods and identify the important parameters. For Gongdo watershed ($366.5km^2$), the SWAT was calibrated for 2 cases of 2002~2006 normal year focusing calibration and 2014~2015 drought focusing calibration respectively. The parameters of N_UPDIS (Nitrogen uptake distribution parameter) and CMN (Rate factor for humus mineralization of active organic nutrients) played important roles for T-N calibration during drought periods. The SWAT SS, T-N, and T-P average $R^2$ (Coefficient of determination) results by focusing on 2014~2015 drought periods calibration showed 0.71, 0.65 and 0.62 while 2002~2006 normal year focusing calibration showed 0.63, 0.58 and 0.50 respectively. Also SWAT SS, T-N, and T-P model efficiency NSE (Nash-Sutcliffe efficiency) results by focusing on drought period (2014~2015) calibrated showed 0.76, 0.77, 0.87 respectively. Even though the SS, T-P parameters were unchanged during the calibration, the SS and T-P results were improved by the hydrological parameters (SCS-CN, SOL_K, SLSOIL) during the drought periods. The SWAT water quality calibration needs to be considered for the movement of SS and nutrients transport especially focusing on the drought characteristics.

The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S

  • Jin, Cheonggil;Choi, Chuluong
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.123-137
    • /
    • 2021
  • In this study, we performed cross calibration of KOMPSAT-3 AEISS imaging sensor with reference to normalized pixels in the Landsat 8 OLI scenes of homogenous ROI recorded by both sensors between January 2014 and December 2019 at the Libya 4 PICS. Cross calibration is using images from a stable and well-calibrated satellite sensor as references to harmonize measurements from other sensors and/or characterize other sensors. But cross calibration has two problems; RSR and temporal difference. The RSR of KOMPSAT-3 and Landsat 8 are similar at the blue and green bands. But the red and NIR bands have a large difference. So we calculate SBAF of each sensor. We compared the SBAF estimated from the TOA Radiance simulation with KOMPSAT-3 and Landsat 8, the results displayed a difference of about 2.07~2.92% and 0.96~1.21% in the VIS and NIR bands. Before SBAF, Reflectance and Radiance difference was 0.42~23.23%. Case of difference temporal, we simulated by 6S and Landsat 8 for alignment the same acquisition time. The SBAF-corrected cross calibration coefficients using KOMPSAT-3, 6S and simulated Landsat 8 compared to the initial cross calibration without correction demonstrated a percentage difference in the spectral bands of about 0.866~1.192%. KOMPSAT-3 maximum uncertainty was estimated at 3.26~3.89%; errors due to atmospheric condition minimized to less than 1% (via 6S); Maximum deviation of KOMPSAT-3 DN was less than 1%. As the result, the results affirm that SBAF and 6s simulation enhanced cross-calibration accuracy.