• Title/Summary/Keyword: calibration equation

Search Result 311, Processing Time 0.031 seconds

J-integral of Penny-Shaped Crack on the End of Stiff Fiber Embedded in Rubbery Materials (고무와 섬유로 구성된 복합체 내의 섬유 끝 부분의 원형 균열에 대한 J-적분)

  • Yang, Gyeong-Jin;Gang, Gi-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.617-624
    • /
    • 2002
  • An equation of J-integral for a penny-shaped crack at the end of the fiber embedded in rubber matrix is proposed. The values of J-integral for the specimens with various crack and specimen radius are obtained by FEA(Finite Element Analysis). The dimensional analysis is applied to derive an equation of J-integral as a nonlinear elastic energy release rate. The geometry and deformation calibration function in an equation of J can be expressed in a separated form. The geometry calibration function characterizing the effects of cord and specimen size is expressed in a polynomial form of fourth order. The deformation calibration function characterizes the effect of the overall level of strain. As approaching the infinitesimal strain, the value of the deformation calibration function approaches the results of LEFM(Linear Elastic Fracture Mechanics).

Calibration of Optically Stimulated Luminescent nanoDot Dosimeter for 6 MV Photon Beam (6 MV 광자 빔에 대한 광자극형광나노닷선량계의 교정)

  • Kim, Jongeon;Kim, Seonghu;Lee, Hyoyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • The purpose of this study is to investigate the calibration of an optically stimulated luminescent nanoDot dosimeter(OSLnD) to 6 MV photon beam. Dose ranges of the calibration of linear and non-linear from the analysis of dose response of the OSLnD were decided. To evaluate the accuracy of calibration equation and the calibration, the sets of the calibration and quality control dosimeter were used to make. The calibrations were performed by the linear and the non-linear in the dose range of 0~300 cGy and 20~1300 cGy, respectively. The errors of the calibration were acquired less than 0.1% respectively from the measurement of the quality control dosimeters for the calibration of linear and the non-linear. This study provides the calibration equation of the OSLnD to the 6 MV photon beam.

Evaluation of Chemical Composition in Reconstituted Tobacco Leaf using Near Infrared Spectroscopy (근적외선 분광분석법을 이용한 판상엽 화학성분 평가)

  • Han, Young-Rim;Han, Jungho;Lee, Ho-Geon;Jeh, Byong-Kwon;Kang, Kwang-Won;Lee, Ki-Yaul;Eo, Seong-Je
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Near InfraRed Spectroscopy(NIRS) is a quick and accurate analytical method to measure multiple components in tobacco manufacturing process. This study was carried out to develop calibration equation of near infrared spectroscopy for the prediction of the amount of chemical components and hot water solubles(HWS) of reconstituted tobacco leaf. Calibration samples of reconstituted tobacco leaf were collected from every lot produced during one year. The calibration equation was formulated as modified partial least square regression method (MPLS) by analyzing laboratory actual values and mathematically pre-treated spectra. The accuracy of the acquired equation was confirmed with the standard error of prediction(SEP) of chemical components in reconstituted tobacco leaf samples, indicated as coefficient of determination($R^2$) and prediction error of sample unacquainted, followed by the verification of model equation of laboratory actual values and these predicted results. As a result of monitoring, the standard error of prediction(SEP) were 0.25 % for total sugar, 0.03 % for nicotine, 0.03 % for chlorine, 0.16 % for nitrate, and 0.38 % for hot water solubles. The coefficient of determination($R^2$) were 0.98 for total sugar, 0.97 for nicotine, 0.96 for chlorine, 0.98 for nitrate and 0.92 for hot water solubles. Therefore, the NIRS calibration equation can be applicable and reliable for determination of chemical components of reconstituted tobacco leaf, and NIRS analytical method could be used as a rapid and accurate quality control method.

Characteristic Responses of Biosensor Based on $H^+$-Selective Membrance Electrode (H$^+$ 선택성 막 전극을 이용한 바이오센서의 감응 특성)

  • Kim, Ki-Myo;Park, Sung-Bae;Hwang, Myoung-Seok;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.6
    • /
    • pp.625-631
    • /
    • 1996
  • The $H^+$-selective membrane consists of tridodecylamine, 2-nitrophenyl octyl ether and a little amount of additive in carboxylated PVC matrix, where penicillinase(Pcase ) and glutaraldehyde may be covalently attached to the matrix. When the $H^+$-selective electrode was used as a detector of biosensor, calibration curve calculated from Nernst equation was not linear. So we investigated the characteristic responses of the $H^+$-selective electrode to the product H+ from hydrolysis of penicillin-G(Pc-G) and plotted calibration curve correlating potential to concentration of Pc-G linearly. The optimal concentration of buffer solution was theoretically calculated and was also experimented. We tried to explain the linear curve of potential to concentration of Pc-G by using Henderson-Hasselbach equation. This method is more effective in calibration curve plotting than any other previous methods. The results obtained may help in further developing pH electrodes with improved analytical preformance.

  • PDF

Development of Near Infrared Spectroscopy(NIRS) Equation of Crude Protein in Wheat Germplasm

  • Hyemyeong Yoon;Myung-Chul Lee;Yumi Choi;Myong-Jae Shin;Sejong Oh
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.100-100
    • /
    • 2020
  • Wheat is mainly composed of carbohydrate but it contains a moderate amount of protein, which gives a very useful characteristics to flour food such as the unique elasticity and stickiness of the dough. We developed a calibration equation for analyzing crude protein content using Near Infrared Spectroscopy to quick analyze the crude protein content of wheat germplasm stored in the National Agrobiodiversity Center, RDA, Korea. The 1,798 wheat germplasms were used to draw up the calibration formula. The crude protein's interval distribution of 1,798 wheat germplasms used for the calibration was 7.04-20.84%, the average content was 13.2%, and standard deviation was 2.6%. The germplasms distribution was composed of a suitable group for the preparation of the calibration formula because the content distribution was a normal, excluding the 13.0-15.5% content section. In order to verify the applicability of the NIRS prediction model, we measured the crude protein content of the 300 wheat germplasms that were not used for the calibration using both Kjeldahl analysis and NIR spectrum. The analysis value calculated using each method were statistically processed, and the test results and statistical indicators of the predictive model were compared. As a result, The R2 value of the optimized NIRS prediction model was 0.997, and the Standard error of Calibration value(SEC) was 0.132, and slope value was 1.000. With prediction model selection, compared to Kjeldahl method, R2 values were 0.994(Kjeldahl), 0.998(NIRS), and the SEC value were 0.191 and 0.132, respectively, comparing the statistical indices of the forecast model. And slope value were 1.013, 1.000, respectively. The analysis of crude protein content by the NIRS predictive model developed by each statistical index showing similar figures is judged to show a high degree of correlation with the Kjeldahl analysis. The proven calibration equation will be used to measure the crude protein content of wheat germplasms held by the National Agrobiodiversity Center, and by dividing the wheat germplasms by their use according to the crude protein content, it will provide useful information to relevant researchers.

  • PDF

Investigation of a Method Measuring Bond에s Work Index of Korean Kaolin by Laboratory Ball Mill (소형 Ball Mill에 의한 고령토의 분쇄 일지수 측정방법의 검토)

  • 심철호;강용식;서태수
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.1
    • /
    • pp.47-55
    • /
    • 1987
  • The purpose of this work is to establish the basic calibration data for the efficiency of grinding by investigating the Bond's Work Index employing Korean Kaolin as a reference mateial with the laboratory-scale ball mill. A small ordinary ball mill has a dimension of 133 inside diameter and 144mm long. The analysis of the experimental results in this work sets up a equivalent calibration method with the laboratory-scale ball mill to those with special mill. The theoretical expression, derived from the rate equation proposed by Miwa, is obtained to anticipitate the stable revolution number for the next grinding cycle. The proposed equation is more systematic and acurate than lshihara's empirical equation is more systematic and acurate than lshihara's empirical equation for the measurement of gindability of a ball mill.

  • PDF

Calibration of Inertial Measurement Units Using Pendulum Motion

  • Choi, Kee-Young;Jang, Se-Ah;Kim, Yong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.3
    • /
    • pp.234-239
    • /
    • 2010
  • The utilization of micro-electro-mechanical system (MEMS) gyros and accelerometers in low-level inertial measurement unit (IMU) influences cost effectiveness in a positive way under the condition that device error characteristics are fully calibrated. The conventional calibration process utilizes a rate table; however, this paper proposes a new method for achieving reference calibration data from the natural motion of pendulum to which the IMU undergoing calibration is attached. This concept was validated with experimental data. The pendulum angle measurements correlate extremely well with the solutions acquired from the pendulum equation of motion. The calibration data were computed using the regression method. The whole process was validated by comparing the measurement from the 6 sensor components with the measurements reconstructed using the identified calibration data.

Development of Measurement Assurance Test Procedures between Calibrations (계기 검교정간의 보증시험 절차의 개발)

  • Yum, Bong-Jin;Cho, Jae-Gyeun;Lee, Dong-Wha
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 1993
  • A nonstandard instrument used in the filed frequently becomes out-of-calibration due to environmental noise, misuse, aging, etc. A substantial amount of loss may result if such nonstandard instrument is used to check product quality and performance. Traditional periodic calibration at the calibration center is not capable of detecting out-of-calibration status while the instrument is in use, and therefore, statistical methods need to be developed to check the status of a nonstandard instrument in the field between calibrations. Developed in this paper is a unified measurement assurance model in which statistical calibration at the calibration center and measurement assurance test in the filed are combined. We developed statistical procedures to detect changes in precision and in the coefficients of the calibration equation. Futher, computational experiments are conducted to evaluate how the power of test varies with respect to the parameters involved. Based upon the computational results we suggest procedures for designing effective measurement assurance tests.

  • PDF

Quantification of Icariin Contents in Epimedium koreanum N. by Using a Near Infrared Reflectance Spectroscopy (NIRS를 이용한 삼지구엽초의 이카린 함량 분석)

  • Kim, Yong-Ho;Choi, Byoung-Ryourl;Baek, Hum-Young;Lee, Young-Sang
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.5
    • /
    • pp.340-343
    • /
    • 2002
  • Near infrared reflectance spectroscopy (NIRS) has become widely accepted for rapid quantitative analysis of components in some crops. Our object was to determine icariin contents in whole plant of Epimedium koreanum by using an NIRS system. Total 150 plant samples previously analyzed by HPLC were scanned by NIRS and 68 samples were selected for calibration and validation equation. A calibration equation calculated by MPLS(modified partial least squares) regression technique was developed and a coefficient of determination in calibration and validation sets were 0.95 and 0.82, respectively. A comparison between NIRS estimation and HPLC value was performed with the remaining samples not included in the calibration and validation sets. Most of samples also showed a positive correlation like a validation set. Our results demonstrate that this developed NIRS equation can be practically used as a mass screening method for rapid quantification of icarin contents in Epimedium koreanum N.

A Study on the CCD Camera Calibration for Close-Range Photogrammetry (근거리 사진측량을 위한 CCD 사진기 검정에 관한 연구)

  • Yeu, Bock-Mo;Lee, Seok-Kun;Choi, Song-Wook;Kim, Gi-Hong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.5 no.1 s.9
    • /
    • pp.159-165
    • /
    • 1997
  • Because CCD camera acquires the digital images without separate processing, its availabilities are increased. In this study, for CCD camera calibration DLT equation and radial or decentering distortion equation are combined and the calibration parameters are calculated using three dimensional test model. The digital images acquired by CCD camera are matched using coefficient of correlation and the three dimensional coordinates of objects are determined. Also, the potential usefulness of CCD camera in close range photogrammetry is examined.

  • PDF