• Title/Summary/Keyword: calibration circuit

Search Result 139, Processing Time 0.028 seconds

A Design of Capacitive Sensing Touch Sensor Using RC Delay with Calibration (캘리브래이션 기능이 있는 RC지연 정전용량 방식 터치센서 설계)

  • Seong, Kwang-Su;Lee, Mu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.80-85
    • /
    • 2009
  • In this paper, we propose a full digital capacitive sensing touch key reducing the effects due to the variations of resistance and clock frequency. The proposed circuit consists of two capacitive loads to measure and a resistor between the capacitive loads. The method measures the delays of the resistor and two capacitive loads, respectively. The ratio of the two delays is represented as the ratio of the two capacitive loads and is irrelative to the resistance and the clock frequency if quantization error is disregarded. Experimental results show the proposed scheme efficiently reduces the effects due to the variations of clock frequency and resistance. Further more the method has 1.04[pF] resolution and can be used as a touch key.

DC-DC Boost Converter using Offset-Controlled Zero Current Sensor for Low Loss Thermoelectric Energy Harvesting Circuit (저 손실 열전변환 하베스팅을 위해 제로전류센서의 오프셋을 조절하는 부스트 컨버터)

  • Joo, Sunghwan;Kim, Kiryong;Jung, Dong-Hoon;Jung, Seong-Ook
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • This paper presents a low power boost converter using offset controlled Zero Current Sensor (ZCS) control for thermoelectric energy harvesting.[1] [5] Offset controlled ZCS uses adjustable pre-offset that is controled by 6bit code each connected gate of NMOS for switching. Offset controlled ZCS demonstrates an efficiency that is higher than using analog comparator ZCS and that is smaller area than using delay line ZCS. Experimentally, the offset controlled ZCS system consumes 10 times less power than analog comparator ZCS based system at similar performance.

Determination of Lead(II) at Nation-Coated Glassy Carbon Electrodes Modified by Tetren-Glycerol (Nafion-Tetren-Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 정량)

  • 반옥기;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2003
  • Differential pulse voltammetry (DPV) using nafion-coated glassy carbon electrodes modified with Tetren(tetraethylene pentamine)-glycerol showed sensitivity for determining lead (II) at low concentration. The Lead (II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry. Various experimental parameters, such as the composition of modifier, preconcentration time, pH of electrolyte (0.1 M acetate buffer), and parameters of differential pulse voltammetry, were optimized. The initial potential was applied for 50 s, the electrode was scanned from -0.9 to -0.3 V, and the anodic peak current was measured at -0.604 V $\pm$ 0.015 V (vs. Ag/AgCl). The calibration plot was obtained in the range 1.0$\times$10$^{-8}$ M~l.0$\times$10$^{-6}$ M with pH 4.5 buffer solution. The detection limit (3$\sigma$) it as low as 5.0$\times$ 10$^{-9}$ M. This method is applied to the determination of lead(II) in a certified reference material and the result agrees satisfactorily with the certified value.

A study on the development of an electromagnetic flowmeter and the characterization of flow signal (전자기유량계의 개발및 신호 특성에 관한 연구)

  • Lim Ki Won;Kim Chang Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

Fasting Heat Production of Growing Buffalo Calves

  • Tiwari, C.M.;Chandramoni, Chandramoni;Jadhao, S.B.;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.3
    • /
    • pp.307-312
    • /
    • 2000
  • Fasting heat production (FHP) of growing buffalo calves (Bubalus bubalis) in the body weight range of 76 to 236 kg was determined using open circuit respiration chamber. The details of the chambers, calibration of gas analysers and operation of the systems are described. Animals were fasted for 96 hrs during which only water was provided. FHP was determined during next 24 hrs. The mean oxygen consumed, carbon dioxide and methane produced and urinary N excretion per 24 h was $17.03{\ell}$, $11.70{\ell}$, and $0.12{\ell}$ and 0.35 g respectively. The mean respiratory quotient ranged from 0.68 to 0.71, which indicated that post absorptive stage is reached after 96 hrs in growing buffalo calves previously fed ammoniated straw-based ration. Mean FHP of calves was $331.4kJ/kg\;W^{0.75}$. FHP of calves with range of mean body weights of 167 to 235 kg, although nonsignificant but, was almost 12% higher than of calves having mean body weight of 101 kg. Suitable exponent to body weight to describe FHP of buffalo calves was 0.87.

An Automatic Teaching Method by Vision Information for A Robotic Assembly System

  • Ahn, Cheol-Ki;Lee, Min-Cheol;Kim, Jong-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.65-68
    • /
    • 1999
  • In this study, an off-line automatic teaching method using vision information for robotic assembly task is proposed. Many of industrial robots are still taught and programmed by a teaching pendant. The robot is guided by a human operator to the desired application locations. These motions are recorded and are later edited, within the robotic language using in the robot controller, and played back repetitively to perform the robot task. This conventional teaching method is time-consuming and somewhat dangerous. In the proposed method, the operator teaches the desired locations on the image acquired through CCD camera mounted on the robot hand. The robotic language program is automatically generated and transferred to the robot controller. This teaching process is implemented through an off-line programming(OLP) software. The OLP is developed for the robotic assembly system used in this study. In order to transform the location on image coordinates into robot coordinates, a calibration process is established. The proposed teaching method is implemented and evaluated on the assembly system for soldering electronic parts on a circuit board. A six-axis articulated robot executes assembly task according to the off-line automatic teaching.

  • PDF

A Low-Voltage Low-Power Opamp-Less 8-bit 1-MS/s Pipelined ADC in 90-nm CMOS Technology

  • Abbasizadeh, Hamed;Rikan, Behnam Samadpoor;Lee, Dong-Soo;Hayder, Abbas Syed;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.416-424
    • /
    • 2014
  • This paper presents an 8-bit pipelined analog-to-digital converter. The supply voltage applied for comparators and other sub-blocks of the ADC were 0.7V and 0.5V, respectively. This low power ADC utilizes the capacitive charge pump technique combined with a source-follower and calibration to resolve the need for the opamp. The differential charge pump technique does not require any common mode feedback circuit. The entire structure of the ADC is based on fully dynamic circuits that enable the design of a very low power ADC. The ADC was designed to operate at 1MS/s in 90nm CMOS process, where simulated results using ADS2011 show the peak SNDR and SFDR of the ADC to be 47.8 dB (7.64 ENOB) and 59 dB respectively. The ADC consumes less than 1mW for all active dynamic and digital circuitries.

A Study on the Sensor for Measuring the High Frequency Magnetic Fields (고주파자계측정용 센서에 관한 연구)

  • Lee, Bok-Hee;Jeong, Seung-Soo;Park, Hyung-Ki;Paek, Yong-Hyun;Yim, Dong-Mook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.114-117
    • /
    • 1992
  • This paper presents the design and calibration methods of self-integrated magnetic sensor. Also the distance response measurement of magnetic field produced a transient large current and the frequency response measurement are carried out As the integrating resistance increases. the sensitivity of the sensor is improved, but the decay time constant of response decreases, Also the experimental results are well agreed with the theoretical analysis of the equivalent circuit.

  • PDF

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Design and Evaluation of the Tension Sensor for Surgical Steel Wires (수술용 강선에 대한 인장력 측정센서의 설계 및 특성평가)

  • Joo, Jin-W;Lee, Bong-S
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.261-271
    • /
    • 1997
  • This paper presents the design process and characteristic test results of tension sensors for measuring the ultimate tension forces of surgical wires. Three types of sensor were designed and tested for calibration. The first two types which transfer the wire tension to the sensing element by direct contact have too much hysterisis errors due to the firctional effect. This error can be considerably reduced in the modified structure, where a cover and a loading button is used to transfer force and moment to the sensing element. The strains predicted by theoretical equations agree well with those by finite element calculations neglecting friction and the strains by finite element analysis considering friction are in good agreement with those measured by four strain gages. The modified ring type tension sensor developed in this paper is expected to be useful for measuring the tension of surgical wires with nonlinearity of 1.31%FS, hysterisis of 5.74%FS and repeatability of 0.19%FS.