• Title/Summary/Keyword: calibrated

Search Result 1,876, Processing Time 0.035 seconds

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects (뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究))

  • Ko, Ki-Duk;Kim, Kyung-Yo;Kim, Jong-Yeol;Lee, Si-Woo;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

Depth error correction for maladjusted stereo cameras with the calibrated pixel distance parameter (화소간격 파라미터 교정에 의한 비정렬 스테레오 카메라의 거리오차 보정)

  • 김종만;손홍락;김성중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.268-272
    • /
    • 1996
  • Error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with some experimental results.

  • PDF

Energy Performance Evaluation of a New Commercial Building using Calibrated As-built Simulation with Monitoring Data (건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가)

  • Song, Su-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.155-166
    • /
    • 2008
  • The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures(ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index(EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building(i.e., calibrated as-built simulation mode]), but doesn't include the simulated ECDMs.

Two Dimensional Atomic Force Microscope (서브나노급 정밀도의 2 차원 원자현미경 개발)

  • Lee, Dong-Yeon;Gweon, Dae-Gab
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1778-1783
    • /
    • 2008
  • A compact and two-dimensional atomic force microscope (AFM) using an orthogonal sample scanner, a calibrated homodyne laser interferometer and a commercial AFM head was developed for use in the nanometrology field. The x and y position of the sample with respect to the tip are acquired by using the laser interferometer in the open-loop state, when each z data point of the AFM head is taken. The sample scanner which has a motion amplifying mechanism was designed to move a sample up to $100{\times}100{\mu}m^2$ in orthogonal way, which means less crosstalk between axes. Moreover, the rotational errors between axes are measured to ensure the accuracy of the calibrated AFM within the full scanning range. The conventional homodyne laser interferometer was used to measure the x and y displacements of the sample and compensated via an X-ray interferometer to reduce the nonlinearity of the optical interferometer. The repeatability of the calibrated AFM was measured to sub-nm within a few hundred nm scanning range.

  • PDF

An Improvement on Estimation for Causal Models of Categorical Variables of Abilities and Task Performance

  • Kim, Sung-Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.1
    • /
    • pp.65-86
    • /
    • 2000
  • The estimates from an EM when it is applied to a large causal model of 10 or more categorical variables are often subject to the initial values for the estimates. This phenomenon becomes more serious as the model structure becomes more serious as the model structure becomes more complicated involving more variables. In this regard Wu(1983) recommends among others that EMs are implemented several times with different sets of initial values to obtain more appropriate estimates. in this paper a new approach for initial values is proposed. The main idea is that we use initials that are calibrated to data. A simulation result strongly indicates that the calibrated initials give rise to the estimates that are far closer to the true values than the initials that are not calibrated.

  • PDF

Distance measurement system compensated parameters for extraction of 3D distance (원거리 물체의 3차원거리 측정시의 파라미터 보정된 거리측정시스템)

  • Kim, Jeong-Man;Kim, Young-Min;Kim, Won-Sup;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.605-606
    • /
    • 2005
  • Depth error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with various experimental results.

  • PDF

Usability Evaluation of Touch Keyboard in Smart Watch Environment

  • Oh, Euitaek;Choi, Jinhae;Cho, Minhaeng;Hong, Jiyoung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.569-580
    • /
    • 2016
  • Objective: This study aims to identify the most effective keyboard layout in the area of performance for securing usability in a smart watch-using environment and to verify the usability of touch keyboard calibrated by hand. Background: It is necessary to understand the environmental characteristics in using the smart watch and to secure the usability of touch keyboard based on this understanding in order to take account of the users who use the touch screen in the extreme input conditions caused by the small screen of a smart watch. Method: 30 participants in this study were required to input characters using the QWERTY keyboard and 3x4 keypad (Naratgul, Chunjiin), which were familiar with them, in order to grasp the keyboard layout suitable in the smart watch- using environment; the performance (error rate, performance time) of this case was measured. In addition, 30 participants in this study were required to input the characters setting the QWERTY keyboard with calibrated touch area and the one with uncalibrated touch area, based on the characteristics of touch behavior, by finger typing the keyboard, with the performance (error rate and performance time) of this case measured. Results: QWERTY keyboard (93.3sec) is found to be 31.2% faster than Naratgul keyboard, a kind of 3x4 keypad, and 43.6% faster than Chunjiin keyboard, in the area of efficiency, in the results of the usability evaluation regarding the keyboard layout. QWERTY keyboard with calibrated touch area (7.5%) is found to be 23.5% improved compared to the QWERTY keyboard with uncalibrated touch area (9.8%) in the area of accuracy (error rate). The results of the usability evaluation regarding the QWERTY keyboard with touch area calibrated by finger typing the keyboard and QWERTY keyboard with calibrated touch area (80.7sec) is found to be 5.7% improved compared to QWERTY keyboard with uncalibrated touch area (85.6sec) in the area of efficiency (performance time). Conclusion: QWERTY keyboard is found to have an effective layout in the area of efficiency in the smart watch-using environment, and its improved usability is verified in the areas of accuracy and efficiency in the QWERTY keyboard with a touch area calibrated by finger typing the keyboard. Application: The results of this study may be used to set up the basic touch keyboard of the smart watch. The input usability is expected to secure the smart watch-using environment, which is an extreme input condition by applying QWERTY keyboard with touch area calibrated by finger typing the keyboard.

3D reconstruction method without projective distortion from un-calibrated images (비교정 영상으로부터 왜곡을 제거한 3 차원 재구성방법)

  • Kim, Hyung-Ryul;Kim, Ho-Cul;Oh, Jang-Suk;Ku, Ja-Min;Kim, Min-Gi
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.391-394
    • /
    • 2005
  • In this paper, we present an approach that is able to reconstruct 3 dimensional metric models from un-calibrated images acquired by a freely moved camera system. If nothing is known of the calibration of either camera, nor the arrangement of one camera which respect to the other, then the projective reconstruction will have projective distortion which expressed by an arbitrary projective transformation. The distortion on the reconstruction is removed from projection to metric through self-calibration. The self-calibration requires no information about the camera matrices, or information about the scene geometry. Self-calibration is the process of determining internal camera parameters directly from multiply un-calibrated images. Self-calibration avoids the onerous task of calibrating cameras which needs to use special calibration objects. The root of the method is setting a uniquely fixed conic(absolute quadric) in 3D space. And it can make possible to figure out some way from the images. Once absolute quadric is identified, the metric geometry can be computed. We compared reconstruction image from calibrated images with the result by self-calibration method.

  • PDF

Atomic Force Microscope for Standard Length Metrology (직교 스캐너와 레이저 간섭계를 사용한 교정용 원자현미경)

  • Lee, Dong-Yeon;Kim, Dong-Min;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1611-1617
    • /
    • 2006
  • A compact and two-dimensional atomic force microscope (AFM) using an orthogonal sample scanner, a calibrated homodyne laser interferometer and a commercial AFM head was developed for use in the nano-metrology field. The x and y position of the sample with respect to the tip are acquired by using the laser interferometer in the open-loop state, when each z data point of the AFM head is taken. The sample scanner which has a motion amplifying mechanism was designed to move a sample up to $100{\times}100{\mu}m^2$ in orthogonal way, which means less crosstalk between axes. Moreover, the rotational errors between axes are measured to ensure the accuracy of the calibrated AFM within the full scanning range. The conventional homodyne laser interferometer was used to measure the x and y displacements of the sample and compensated via an X-ray interferometer to reduce the nonlinearity of the optical interferometer. The repeatability of the calibrated AFM was measured to sub-nm within a few hundred nm scanning range.

Simulation and Model Validation of a Parabolic Trough Solar Collector for Water Heating

  • Euh, Seung-Hee;Kim, Dae Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.17-26
    • /
    • 2013
  • The aim of this study is to analyze the performance of a parabolic trough solar collector (PTC) for water heating and to validate the model performance. The simulated model was compared, calibrated and verified with the experimental results. RMSE (Root mean square error) was used to calibrate the convective heat transfer coefficient between the absorber pipe and the ambient air which was the main factor affecting the heat transfer associated with the PTC. The calibrated model was better fitted with the experimental model. The maximum, minimum and mean deviation between the measured and predicted water temperatures differed only $0.81^{\circ}C$, $0.09^{\circ}C$ and $0.31^{\circ}C$ respectively in the calibrated model. RMSE values were decreased from 0.5389 to 0.4910, 0.0134 to 0.0125 and R-squared was increased from 0.9955 to 0.9956 after calibration. The temperature of water was increased from $33.7^{\circ}C$ to $48^{\circ}C$ in 12hour test. The thermal efficiency of the collector was calculated to be 55%. The calibrated model showed good agreement with the experimental data for model validation.