• Title/Summary/Keyword: cable fire

Search Result 141, Processing Time 0.02 seconds

An Experimental Study on the Fire Monitoring System for Tunnel Using SMA and Fiber Optic Cable (형상기억합금과 광케이블을 이용한 터널의 화재감지 시스템 개발에 관한 실험적 연구)

  • Hwang, Ji-Hyun;Park, Ki-Tae;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.128-134
    • /
    • 2014
  • Recently, design and construction of street tunnels tend to focus on cost reduction and preservation of nature. Accordingly, research is actively being carried out to quickly detect fires when they occur in tunnels, which have partially closed structures. Among such research, fire detection methods using optical fiber sensors have a wide bandwidth and fast transmission speed, while using light as a medium. Therefore, it does not receive electrical interference and there is almost no loss of information during transmission, while also having little noise as well. In relation to this, a fire monitoring system that can accurately detect the location of fires in real time using shape memory alloy and optical cables was developed in this study. In order to verify the developed method, light loss measurement test was conducted according to indoor temperature changes, while also conducting fire simulation tests by installing test beds in common underground zones with different external environments of temperature and distance. Upon carrying out experiments, the fire monitoring system developed in this study was found to be able to detect fires in long distance sections in real time.

Dynamic characteristics between waves and a floating cylindrical body connected to a tension-leg mooring cable placed in a simulated offshore environment

  • Song, Juhun;So, Soo-Hyun;Lim, Hee-Chang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.375-385
    • /
    • 2016
  • Given the rapid progress made in understanding the dynamics of an offshore floating body in an ocean environment, the present study aimed to simulate ocean waves in a small-sized wave flume and to observe the motion of a cylindrical floating body placed in an offshore environment. To generate regular ocean waves in a wave flume, we combined a wave generator and a wave absorber. In addition, to precisely visualise the oscillation of the body, a set of light-emitting diode illuminators and a high-speed charge-coupled device camera were installed in the flume. This study also focuses on the spectral analysis of the movement of the floating body. The wave generator and absorbers worked well to simulate stable regular waves. In addition, the simulated waves agreed well with the plane waves predicted by shallow-water theory. As the period of the oncoming waves changed, the movement of the floating body was substantially different when tethered to a tension-leg mooring cable. In particular, when connected to the tension-leg mooring cable, the natural frequency of the floating body appeared suddenly at 0.391 Hz as the wave period increased.

Study on Property Modification with Kind and Additive Amount of Plasticizer in the Manufacture of Compounds for Cable Sheath (전선피복용 컴파운드의 제조에서 가소제의 종류와 첨가량에 따른 물성 변화 연구)

  • Li, Xiangxu;Lee, Sang Bong;Cho, Ur Ryong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.11-16
    • /
    • 2019
  • The four different polymer compounds were manufactured with the two kinds of plasticizers [(di-2-ethylhexyl sebacate(DOS), and di-2-butyl sebacate(DBS)] and two different additive amounts(18, 26 phr) of the same plasticizer for making cable sheath for ship. Ethylene-vinylacetate, ethylene-propylene-diene-copolymer as matrix polymers and ethylene-vinylacetate grafted maleic anhydride as coupling agent were selected for compounding with fire retardant, closslinking agent, filler, and other additives besides plasticizer. The compound including DOS showed the higher ${\Delta}T$ than that including DBS at the same additive amount in the rheology test. And with increasing plasticizer, the compounds resulted in lower tensile strength and higher elongation by lubricating effect of plasticizer. DOS yielded better aging resistance and cold resistance than DBS due to the good heat resistance and low solidifying point of DOS compared to DBS.

Study on Disaster Prevention System for Long Span Bridge over the Sea (장대해상교량의 방재시스템 구축에 관한 연구)

  • Kong, Byung-Seung
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.59-64
    • /
    • 2009
  • Bridge types such as the suspension bridges and the cable stayed bridges maintained by cables present the dangerous possibility of a ship running through the bottom of the bridge. Due to hangers and main cables in the upper structural system, the bridge is also susceptible to disasters. However, these cable bridges are usually used for long span bridges over the sea. This structure is relatively more exposed to disasters, such as wind, hail, and earthquake, than other structures. This structure also has the potential to cause car accidents on account of the poor visibility due to foggy conditions. If a fire breaks out because of a car accident due to wind, a car explosion will likely occur.

Analysis of arc-energy with joint box type through a field test (인공지락 실증시험을 통한 접속함 종류별 아크에너지 해석)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Lee, D.I.;Kim, H.D.;Oh, C.H.;Lim, H.E.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.715-717
    • /
    • 2005
  • This paper analyses the arc-energy with joint box type through a field test on underground power OF cable. In order to obtain the data, the actual proof test using short-circuit generation for real scale power transmission tunnel carried out. This paper is expected to contribute the fire accident prevention on underground power cable systems and the believability improvement of electric power facilities.

  • PDF

A Comparative Study on the Toxicity Evaluation for Fire Smoke by FDS (FDS를 이용한 화재시 연소가스의 독성평가에 관한 비교 연구)

  • Jeong, Beom Jin;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • FDS (Fire Dynamics Simulator) is the most widely used computational fluid dynamics software in the fire safety engineering community, and it is applicable to various evaluations of fire growth and its effects. This study made use of a range of outputs from FDS simulation to predict FED (Fractional Effective Concentration) and FEC (Fractional Effective Concentration) levels which are often adopted to evaluate toxicity of fire smoke. As it is not possible to calculate these values directly from outputs of FDS, it was necessary to produce them by means of additional calculation procedures incorporating results of evacuation simulation. In this study, the latest version of FDS, which was recently updated in November 2013, was utilized for the purpose of quantitative comparison with the old version of FDS. As a result, it was found that they make about 10 percent difference on average in predicting FED and FEC levels for the cable fire case study.

Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room (자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Youm, Kwang Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.15-19
    • /
    • 2013
  • This paper is to analyze and study the cause of fire examples produced because of short phenomenon by electric connecting damage and contacting engine over-heating with combustible materials in engine room of vehicle. In the first example, it knew the fact that the fire produced by contacting with body of vehicle because of loosed of bracket bolt for wire fixing that installed on the transmission case the battery power cable supply the power from battery of engine room to starting motor. In the second example, it certified the fire by short phenomenon because of insulation tape melting wound wiring lined from battery to starting motor. In the third example, it sought for fire's cause that melting phenomenon the wire coating by overheated engine as the wire disconnected with connector by the vibration. Therefore, the fire of system including engine electric made in the danger the people in the car by failure of engine and other system. And than, the car's driver must manage and examine a vehicle conscientiously.

Environmental Test of Avionics Equipment for Lightning Indirect Effect (낙뢰 간접영향에 대한 항공전자장비의 환경시험)

  • Jeong, Duck-young;Yang, Hyun-duck
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 2013
  • Before avionics equipment are installed in aircraft, several environmental tests such as temperature, vibration, lightning, fire etc. must be conducted. One of the environmental tests is to substantiate protection designs of lightning indirect effect. It can be showed through RTCA DO-160G, section22 "Lightning Induced Transient Susceptibility" test. An additional test of aircraft level is required as well after installation of avionics equipment.

Comparison of Korean and Foreign Standards for Cable Flame Tests (원자력 발전소 케이블의 화염 전파시험 국내외 기준 비교)

  • Lee, Dong-Min;Cho, Young-Se;Yim, Hyun-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.94-99
    • /
    • 2011
  • 원자력 발전소에 사용되는 케이블은 화재발생시 화재전파를 억제하기 위해 일정수준의 화염시험을 만족한 것을 사용하도록 규정되어 있다. 이러한 케이블 화염시험 기준은 나라마다 약간씩 차이가 있는데 본 논문에서는 국내와 미국, 프랑스, 캐나다의 원자력 발전소 케이블 화염시험 기준의 국가별 차이점을 비교 분석 하였다. 비교분석결과 각 나라의 케이블 화염시험 코드는 세부 항목별로 약간씩 차이가 있으나 전체적으로 모든 코드가 동등한 수준의 기준을 갖고 있는 것으로 분석 되었다. 따라서 어느 하나의 코드를 만족하는 전기케이블은 다른 코드의 요구 사항을 만족하는 것으로 볼 수 있다.

  • PDF