• Title/Summary/Keyword: cable element

Search Result 386, Processing Time 0.024 seconds

Development of a Software to Evaluate the CPES(Cable Penetration Fire Stop) System in Nuclear Power Plane I (원자력발전소 케이블관통부 충전시스템 평가용 소프트웨어 개발 I)

  • 윤종필;권성필;조재규;윤인섭
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2004
  • In this work the dynamic heat transfer occurring in a cable penetration fire stop system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealants. Here was carried out an experiment to observe the heat transfer in the cable penetration fire stop system made of DOW CORNING products. The dynamic heat transfer occurring in the fire stop system is formulated in a parabolic partial differential equation subjected to a set of initial and boundary conditions. And it was modeled, simulated, and analyzed. The simulation results were illustrated in three-dimensional graphics and were compared with experimental data. Through the simulations, it was shown clearly that the temperature distribution was influenced very much by the number, position, and temperature of the cable streams. It also was found that the dynamic heat transfer through the cable streams was one of the most dominant factors, and the feature of heat conduction could be understood as an unsteady-state process. It is certain that these numerical results are useful for making a performance-based design for the cable penetration fire stop system.

Simulation of Breakdown in XLPE Cable Using FEM (유한요소법을 이용한 XLPE 케이블내의 절연파괴 모의실험)

  • 장인범;김용주;한기만;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.313-316
    • /
    • 1995
  • In this study, in case the lead sheath of XLPE cable (radius : 15cm, inner conductor radius : 5cm, insulation paper raidius : 6cm, dc voltage : 1MV) is harmed, so that breakdown process by inhomogeneous eletric field is simulated with Finite Element Method. The result of simulation showed that defect of lead sheath layer caused breakdown.

  • PDF

Analysis of dynamic behavior for truss cable structures

  • Zhang, Wen-Fu;Liu, Ying-Chun;Ji, Jing;Teng, Zhen-Chao
    • Steel and Composite Structures
    • /
    • v.16 no.2
    • /
    • pp.117-133
    • /
    • 2014
  • Natural vibration of truss cable structures is analyzed based upon the general structural analysis software ANSYS, energy variational method and Rayleigh method, the calculated results of three methods are compared, from which the characteristics of free-vibration are obtained. Moreover, vertical seismic response analysis of truss cable structures is carried out via time-history method. Introducing three natural earthquake waves calculated the results including time-history curve of vertical maximal displacement, time-history curve of maximal internal force. Variation curve of maximal displacement of node along span, and variation curve of maximal internal force of member along span are presented. The results show the formulas of frequencies for truss cable structures obtained by energy variational method are of high accuracy. Furthermore, the maximal displacement and the maximal internal force occur near the 1/5 span point. These provide convenient and simple design method for practical engineering.

A Study on the Transient State Characteristics of TFR-8 Cable caused by Over Current (과전류에 의한 TFR-8 케이블의 과도상태 특성에 관한 연구)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • The incidence of fires caused by electrical factors has increased with the growth in domestic electrical consumption. According to the national fire data system of national emergency management agency, electrical fires accounted for 20% of all domestic fires in the last 10 years. Electrical fires are mainly caused by short circuit, leakage current, defect in an electrical equipment, over load, utility fault, etc. The fault current can be several times larger than the nominal current, thereby exceeding the rated current of cable. Consequently, the cable conductor, typically copper wire, heats up to a temperature that ignites surrounding combustibles. This paper describes the transient characteristics of the 0.6/1kV, TFR-8 cable have been investigated, and analyzed under the over current conditions for reduce the risk of electrical fire by experimental and FEM analysis. The experimental and FEM(Finite Element Method) analysis results of temperature and resistance variation according to the over current in copper wires were analyzed. The experimental results coincide well with the FEM analysis.

Analysis on the Switching Surge characteristic of Cable Pulling of High-Voltage Induction Motor Fed by Inverter (인버터 구동 고압 유도전동기의 케이블 포설시 스위칭 써지 특성 분석)

  • Kwon, Young-Mok;Kim, Jae-Chul;Song, Seung-Yeop;Shin, Joong-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.63-65
    • /
    • 2004
  • The recent advancement in the power electronic technique has increased the use of induction motor fed by inverter using high-frequency switching devices. Also the tendency is toward larger size and higher voltage. Therefore, The IGBT (Insulated-Gate Bipolar Transistor) that is high switching frequency element has been using increase. But, The switching surge voltage was occurred by high switching frequency of inverter has appeared a voltage doubling in the motor input terminal due to mismatching of cable characteristic impedance and motor characteristic impedance. Actually, The Switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. The short during rise time of switching surge and cable length is increased, the maximum transient voltage seen at the motor terminals increases. In this paper, Analyzed switching surge transient voltage of power cable pulling is used EMTP(Electromagnetic Transient Program) at the induction motor terminal and in cable.

  • PDF

Analysis of Eddy Current Loss Considering Interaction Effect in Metal Sheath of 154 kV Three Phase Power Cable (154 kV 3상 전력 케이블의 상호작용에 따른 금속 Sheath에서 발생하는 와전류 손실 분석)

  • Im, Sang Hyeon;Kim, Ki Byung;Park, Gwan Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.389-392
    • /
    • 2020
  • In order to accurately predict the losses in the power cable, analysis of the eddy current losses in the metal sheath is required. The copper loss is easily calculated by the resistance and current of the conductor, but it is difficult to measure and predict the eddy current generated from the metal sheath. For this purpose, the previous study analyzed the eddy current loss in single phase cable, but there is a limit to apply it because three phase cables are used in real environment. Therefore, in this paper, the eddy current loss occurring in the metal sheath of three phase cable according to the cause was analyzed theoretically. In addition, the eddy current loss occurring in the triangular and horizontal array were predicted through electromagnetic numerical analysis.

Experimental and Theoretical Study on the Prediction of Axial Stiffness of Subsea Power Cables

  • Nam, Woongshik;Chae, Kwangsu;Lim, Youngseok
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.243-250
    • /
    • 2022
  • Subsea power cables are subjected to various external loads induced by environmental and mechanical factors during manufacturing, shipping, and installation. Therefore, the prediction of the structural strength is essential. In this study, experimental and theoretical analyses were performed to investigate the axial stiffness of subsea power cables. A uniaxial tensile test of a 6.5 m three-core AC inter-array subsea power cable was carried out using a 10 MN hydraulic actuator. In addition, the resultant force was measured as a function of displacement. The theoretical model proposed by Witz and Tan (1992) was used to numerically predict the axial stiffness of the specimen. The Newton-Raphson method was employed to solve the governing equation in the theoretical analysis. A comparison of the experimental and theoretical results for axial stiffness revealed satisfactory agreement. In addition, the predicted axial stiffness was linear notwithstanding the nonlinear geometry of the subsea power cable or the nonlinearity of the governing equation. The feasibility of both experimental and theoretical framework for predicting the axial stiffness of subsea power cables was validated. Nevertheless, the need for further numerical study using the finite element method to validate the framework is acknowledged.

Stochastic Finite Element Analysis for Truss Structures (트러스구조물의 확률론적 유한요소 해석)

  • Bang, Myung Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 1993
  • Finite element analyses are conducted with stochastic elastic moduli when truss structures are subjected to static loads of a deterministic nature. Stochastic stiffness matrix is derived from stochastic shape functions and numerical analyses are performed within the framework of the Monte Carlo method. Analysis methods are verified for the space truss and applied to cable stayed bridge for determining the cable force.

  • PDF

Finite Element Analysis using Curvilinear Square Elements (곡선형 사각요소에 의한 유한요소 해석)

  • 이직렬;김정기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.10 no.2
    • /
    • pp.76-81
    • /
    • 1985
  • This paper presents basis functions for curvilinear square elements and describes finite element analysis for coaxial cable and coaxial cross-section waveguide. On the case of coaxial cable, the more exact results is obtained by the propotional elements than by the equal elements with the same number of elements. It is found that the cutoff frequency of coaxial cross-sectional waveguide is more dependent on the inner and outer radius than the cross-sectional angle.

  • PDF

Analytical and experimental postbuckling of conditioned cables

  • Rivierre, L.;Polit, O.;Billoet, J.L.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.595-614
    • /
    • 2001
  • This paper studies the behaviour of a homogeneous cable in a horizontal rigid duct and loaded by an axial compressive force. This behaviour is characterized by spatial buckling modes, named sinusoidal and helical, due to friction and total or partial cable locking. The evaluation of critical buckling loads involved by drilling technology has been studied by many authors. This work presents a new formulation, taking the friction effects into account, for the transmission of the axial load during the postbuckling process. New analytical expressions of pitches in both buckling cases are also given. A life-sized bench is presented, which permits to study the laying of optical fiber cables by squeezing them into an underground duct. Finally, analytical solutions are compared with experimental tests and finite element simulations.