• 제목/요약/키워드: butt-joint

검색결과 269건 처리시간 0.021초

조선용 강재의 맞대기 이음에서 팁회전 아크 용접의 공정 변수에 따른 용접 특성 분석 (Weld Characteristic Analysis for Weld Process Variables of Tip-Rotating Arc Welding in Butt Joint of Shipbuilding Steels)

  • 이종중;안상현;박영환
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.105-112
    • /
    • 2021
  • Reduction of weld distortions and increase in productivity are some of the major goals of the shipbuilding industry. To address these issues, many researchers have attempted to apply new welding processes. In the shipbuilding industry, steel is the candidate material of choice owing to its good weldability. However, conventional welding techniques are not feasible for avoiding welding problems. Tip-rotating arc welding is one of the high-efficiency welding process that has several advantages, such as high welding speed, high melting rate, low heat input, and less distortion. The present study investigates the influence of the welding variables on the weld characteristics of tip-rotating arc welding. Welding was performed using EH36 as the base metal and SM-70s as the filler metal, which are widely used in shipbuilding. Basic experiments were conducted to understand the effects of the major welding variables, such as welding and tip-rotating speeds. The distortion and mechanical properties of the optimal welding conditions were used to evaluate the tip-rotating arc welding performance. Consequently, the feasibility of the tip-rotating arc welding process for joining steel components was investigated, so that the optimized welding conditions could be applied directly to ship body welding to enhance the quality of the welded joints.

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

서양의 전통도배에 관한 이론적 고찰 (A theoretic study about western traditional wallpaper hanging)

  • 임선양
    • 디자인학연구
    • /
    • 제19권2호
    • /
    • pp.207-216
    • /
    • 2006
  • 벽지는 본래 종이가 지닌 성질상 실내장식에 있어서 수명이 가장 짧다는 특징이 있지만, 벽면의 시각적인 효과의 다양함으로 현대 벽장식 마감재중 가장 중요한 요소가 되었다 벽지는 종이의 특성상 역사적 유물 보존이 어렵고 그에 관한 기록이 미흡하며 건축물의 실내공간이 잘 유지되었거나, 광고로 사용되었던 다양한 상업용 샘플과 여러 책자에 의해서만 고증되고 있다. 종이벽지와 도배 자료들을 근거로 18세기의 영국을 중심으로 현대 벽지도배의 발전과 벽지산업의 이론적 체계 확립을 위해 과거의 전통적 벽지도배의 역사적 배경연구와 기술적, 상업적 배경의 근원을 이론적으로 고찰하여 전통적 벽지도배의 상업적 역사성을 재 인식하고자한다. 벽지도배의 이론적 연구를 통해 전통적 도배방법과 초배지의 전승, 반복이음 방식을 이용한 패턴의 양식화, 벽지도배의 분업화와 상업적 비용의 세분화, 과거 전통접착 방법의 전승, 띠벽지의 유래, 전통적 종이벽지의 실용성과 초기 도배기술의 다양한 기능성, 맞대이음 방식에서 중복이음 방식의 변화, 여성의 벽지선택을 통한 DIY제품의 개발 등을 이론적으로 고찰하였다. 벽지는 지금도 장식적, 기능적 벽 마감재 또는 벽 처리를 위한 가장 대중적인 재료로서 다른 재료들보다도 가장 선호하는 제품으로 남아 있다. 이러한 벽지의 도배 기술과 상업성을 역사적으로 고찰하여 전통 벽지도배의 이론적 체계 확립을 위한 중요한 자료이며 미래 벽지산업의 방법론적 접근을 위한 벽지역사의 근원이 될 수 있는 연구라고 사료된다.

  • PDF

마찰교반접합된 이상 스테인리스강의 미세조직 및 기계적 특성에 관한 연구 (Study on microstructure and mechanical properties of friction stir welded duplex stainless steel)

  • 최돈현;안병욱;연윤모;송건;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.24-24
    • /
    • 2010
  • 마찰교반접합법은 특정한 회전수로 회전하는 용접 툴을 이용하여 접합하고자 하는 피접합재의 맞댄면에 삽입시킨 후 툴을 이동시키거나 혹은 시편을 견고하게 고정시킨 장치(backing plate)가 움직여 고상 상태에서 접합이 이루어진다. 알루미늄, 마그네슘 등 비교적 융점이 낮은 저융점 재료의 재료에 처음 적용이 되어 많은 연구가 활발히 진행되었고 타 용접방법에 비해 우수한 접합특성을 나타내었다. 최근 이러한 마찰교반접합은 이러한 저융점 재료를 넘어서 스틸, 타이타늄, 니켈 등과 같은 고융점 재료 등에 대한 적용이 늘어나고 있다. 마찰교반접합을 이용하여 이러한 고융점 재료의 접합 경우 내마모성 및 내열성 등의 내구성이 갖추어진 툴과 이러한 툴을 냉각시킬 수 있는 냉각 장치 등이 필요로 하나 경제적 측면이나 접합부의 우수한 특성 등을 고려 할 때 그 적용 및 발전 가능성이 매우 높다고 볼 수 있다. 2상 스테인레스 강은 금속 조직적으로 페라이트와 오스테나이트 상이 거의 1:1의 동등한 비율로 매우 미세하게 결합된 구조를 가지고 있다. 또한 이상 스테인레스 강은 각상의 개개의 특성에 기인하여 염소 분위기에서 응력부식 저항성이 우수하고, 공식과 틈부식에 대한 저항성이 매우 뛰어나다. 그리고 이상 스테인레스 강은 비교적 고가인 Ni이 일반 오스테나이트 스테인리스 강의 약 1/2의 수준으로 적게 포함이 되어 경제적인 이점을 지니고 있으며 또한 용접성이 좋아 산업계의 수요는 현재 점차 증가하고 있는 상황이다. 하지만 이러한 이상 스테인리스 강은 용접 후 페라이트 상의 조대화, 그리고 페라이트 상의 분율이 오스테나이트 상의 분율보다 높아지게 되어 용접부에서의 저온 인성 감소 및 내식성 저하 등의 문제가 발생하게 된다. 그리하여 용접 시 이러한 문제점을 해결하기 위해서는 입열량의 조절이 가장 필요로 하는 것으로 알려져 있다. 본 연구에서는 마찰교반용접을 이용하여 두께 3mm의 대표적인 이상 스테인리스 강인 SAF2205 스테인리스 강에 대해 맞대기 마찰교반접합을 실시하였다. 툴 회전속도를 변수로 하여 접합을 실시하였으며 접합 시 툴은 $Si_3N_4$ 툴을 사용하였다. 접합 후 외관상태 점검, 미세조직 관찰, 경도 및 인장강도 측정 등의 실험을 실시하였고, 이러한 결과를 이용하여 미세조직과 기계적 특성과의 관련성을 조사하였다.

  • PDF

구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향 (THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR)

  • 이강;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향 (Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws)

  • 신현모;조욱;정창모
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 연구는 external butt joint 연결 형태를 가진 임플랜트 시스템에서 티타늄 합금 나사와 텅스텐 카바이드와 탄소로 코팅한 나사의 압축력 및 조임 회전각 측정을 통해 동일한 전하중을 얻는 데 있어 코팅나사 사용이 갖는 임상적 효율성을 간접적으로 비교해 보고자 하였다. 본 연구에서는 Osstem Implant의 US II 시스템 고정체(${\phi}=4mm$)와 Cemented abutment를 사용하여 티타늄 합금(Ta) 지대주 나사 및 텅스텐 카바이드와 탄소로 표면 처리한(WC/CTa) 지대주 나사에 30Ncm의 조임 회전력을 적용한 후 압축력 및 조임 회전각을 측정하였다. 다음 WC/CTa 지대주 나사에서 측정된 압축력의 평균값을 계산하고 이를 Ta 지대주 나사에 적용하여 동일한 압축력이 가해질 때의 조임 회전력 값을 측정하였다. 그리고 실험결과 측정된 조임 회전력의 평균값을 Ta 나사에 적용한 후 조임 회전각을 측정하여 비교해 본 결과 다음과 같은 결론을 얻었다. 30Ncm의 조임 회전력에서 텅스텐 카바이드/탄소 코팅 나사가 티타늄 합금 나사보다 압축력과 회전각이 더 높게 나타났다. 텅스텐 카바이드/탄소 코팅 나사에 30Ncm의 조임 회전력을 적용하여 발생한 압축력을 얻기 위해서는 티타늄 합금 나사의 경우 55.6Ncm의 조임 회전력이 필요하였으며, 회전각에는 두 나사 간에 차이가 없었다.

AZ61 마그네슘 합금 마찰교반용접부의 기계적 특성 평가 및 미세조직 분석 (Evaluation of Mechanical Properties and Analysis of Microstructure of AZ61 Magnesium Alloy Butt Joints by Friction Stir Welding)

  • 선승주;김정석;임재용;이우근;고요한;김영민;유봉선
    • 한국철도학회논문집
    • /
    • 제19권4호
    • /
    • pp.417-426
    • /
    • 2016
  • 본 연구에서는 AZ61 압출 판재 마찰교반용접부의 기계적 강도 평가와 미세조직 평가를 수행하여 최적의 용접조건을 도출하였다. 용접조건은 용접 툴의 회전속도 400, 600, 800rpm, 이송속도 200, 300, 400mm/min으로 선정하였다. 인장시험 및 경도시험을 통해서 용접부의 기계적 강도 평가를 하였으며, 파단면 관찰과 용접부 단면 미세조직 관찰을 통해서 용접부의 결함 유무를 확인하였다. 용접부 특성 평가 결과 본 연구에서 제시한 용접조건 내에서 AZ61 압출 판재의 최적용접조건은 회전속도 800rpm, 이송속도 200mm/min이었고, 용접부의 인장강도, 항복강도 그리고 연신율은 모재 대비 79.0%, 65.4%, 30.1%로 측정되었다.

내측연결형 임플란트에 체결한 지대주의 수직침하에 대하여 반복하중이 미치는 영향 (Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study)

  • 설현우;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.315-322
    • /
    • 2013
  • 연구 목적: 내측연결형 임플란트와 지대주의 연결체에 반복하중을 부여하였을 때 수직 침하를 평가하고자 하였다. 연구 재료 및 방법: 외측연결형 임플란트와 내측연결형 임플란트에 세 종류의 시멘트유지형 지대주를 각각 장착하였다. 즉, 외측연결형 지대주(Ext 그룹), 내측연결형 1-piece 지대주(Int-1 그룹), 내측연결형 2-piece 지대주(Int-2 그룹)를 사용하였으며, 각 그룹마다 7개의 시편을 준비하였다. 임플란트-지대주 연결체에 수직하중을 적용하기 위하여 임플란트 받침대에 고정한 후, 4 Hz의 빈도로 $150{\pm}10N$의 반복하중을 가하였다. 수직침하량은 0, 5, 10, 50, 100, 1,000, 5,000, 10,000회의 반복하중 후에 각각 측정하였다. 반복측정분산분석(RM-ANOVA)를 이용하여 반복하중의 영향을 분석하였으며, 패턴변화를 관찰하기 위하여 선형혼합모형(linear mixed model)을 사용하였다. 유의수준은5% 로 설정하였다. 결과: 10,000회 반복하중 후 수직침하량은, Ext 그룹에서 $0.714{\pm}0.488{\mu}m$, Int-1그룹에서 $5.286{\pm}1.604{\mu}m$, Int-2 그룹에서 $11.429{\pm}1.902{\mu}m$를 나타내었다. 패턴분석에서는, Int-1 그룹 및 Int-2 그룹에서 지속적인 수직침하가 관찰되었으며, Ext그룹에서는 수직침하현상이 관찰되지 않았다. 결론:10,000회 반복하중 후의 선형혼합모형을 통한 분석에서, Ext그룹은 수직침하현상을 보이지 않았으나, Int-1 및 Int-2 그룹은 지속적인 수직침하현상을 나타내었다. 또한, Int-2그룹에서 Int-1그룹보다 더 많은 수직침하량이 관찰되었다.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF