• Title/Summary/Keyword: bus operating

Search Result 310, Processing Time 0.026 seconds

Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul (서울 일부 지역 교통수단의 실내 공기질 평가)

  • Sohn Jong-Ryeul;Choi Dal-Woong;Choi Jung-Sook;Woo Wan-Gi
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.

The Relationship Between Congestion Pricing and In-vehicle Crowding Level in Public Transport (혼잡통행료 징수와 대중교통 차내 혼잡수준의 관계)

  • YU, Sang-Gyun;BAE, Gi-Mok
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.6
    • /
    • pp.510-522
    • /
    • 2016
  • In studies involving public transport, social welfare improvement is simply explained by the increase in public transport demand. However, the increase in the demand for public transport is mostly observed by the change in the frequency of public transport service, and in-vehicle crowding in public transport has not been an object of concern. This study examines and tries to reveal the cause of the changes of the social welfare and in-vehicle crowding of the changing public transport from imposing congestion pricing. We observe that congestion pricing increases in-vehicle crowding in public transport. This predictable phenomenon is more exacerbated in case of not operating bus-only lane. It should be noted that in-vehicle crowding is more increased in suburban, but in First-best toll system it tends to get worse less than it in other congestion pricing systems. We identify that the change of in-vehicle crowding is affected by the change of proximity of the housing to workplace, the number of commuting trips, and unpredictable distortion effect of the congestion charge.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Variable Emission Factor Prediction Model for An Air Quality Assessment of Transportation Projects (교통사업의 대기질 평가를 위한 가변적 배출계수 예측모형)

  • Lee, Gyu-Jin;Choe, Gi-Ju;Yu, Jeong-Hun;O, Se-Chang
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.6
    • /
    • pp.117-128
    • /
    • 2011
  • In this study, a model is developed to predict emission factors, which aims to objectively evaluate the impact of transport projects on air quality. Two emission prediction models for the years of 2015 and 2030 are developed using the historical trends in vehicle aging and vehicle deterioration factors. The analysis results show that the emission factors under the operating speed of 30km/h for the year 2030 are 5~37% and 2~83% less than those used in the current studies for passenger cars and bus/trucks, respectively. The statistically validated experiment results demonstrate the applicability of the proposed model to evaluation of the impact of transport policies on air quality.

Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines (해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상)

  • Kang, Ja-Yoon;Han, Dae-Su;Suh, Yong-Sug;Jung, Byoung-Chang;Kim, Jeong-Joong;Park, Jong-Hyung;Choi, Young-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

Study on the Performance Characteristics of the Roof Mounted Electrical Air Conditioning System Using Inverter Scroll Compressor (인버터 스크롤 압축기를 적용한 루프형 전동공조시스템의 냉방성능특성에 관한 연구)

  • Lee, Moo-Yeon;Won, Jong-Phil;Lee, Dong-Yeon;Cho, Chung-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4308-4313
    • /
    • 2011
  • The objective of this study is to investigate the cooling performance of the roof mounted air-conditioning system using electric driven scroll compressor for zero emission vehicles. This air conditioner with air source was used R-134a as a refrigerant and tested under various operating conditions such as refrigerant charge amount and indoor temperature, and compressor frequencies. Experimental results revealed that at all tested compressor frequencies, heat transfer rate of the evaporator increased and the cooling COP increased with the indoor temperature. In addition, the heat transfer rate of the evaporator was over 25.0kW sufficient for the cooling loads of an electric bus.

Requirement Analysis and Development of TCMS (종합제어장치(TCMS) 요구사항 분석과 개발)

  • Choi, Byoung-Wook;Seo, In-Myung;Kim, Soo-Ho;Park, Jong-Heon
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.507-514
    • /
    • 2011
  • Recently, we developed a new subway train with many cooperative companies. The main controller of the subway train is Control and Monitoring System (TCMS), so we conducted requirement analysis of TCMS considering system performance, easy maintenance and service oriented flexibility. Hence, we adopted new bus architecture and QNX as a Real-time Operating System (RTOS) and developed hardware systems. The functions of TCMS are employed into two computers, service computer and control/monitor computer, to increase on their performance and to yield easy maintenance and to satisfy customer needs. The TCMS controls and monitors control devices equipped in the train through various protocols which are implemented in hardware. In order to evaluate the performance of the system and to satisfy reliability, various experiments including EMC/ECI were performed. Now the TCMS is installed on the newly developed train and is under performance evaluation through test driving.

CPLD Implementation of SEED Cryptographic Coprocessor (SEED 암호 보조 프로세서의 CPLD 구현)

  • Choi Byeong-Yoon;Kim Jin-Il
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.2
    • /
    • pp.177-185
    • /
    • 2000
  • In this paper CPLD design of cryptographic coprocessor which implements SEED algorithm is described. To satisfy trade-off between area and speed, the coprocessor has structure in which 1 round operation is divided into three subrounds and then each subround is executed using one clock. To improve clock frequency, online precomputation scheme for round key is used. To apply the coprocessor to various applications, four operating modes such as ECB, CBC, CFB, and OFB are supported. The cryptographic coprocessor is designed using Altera EPF10K100GC503-3 CPLD device and its operation is verified by encryption or decryption of text files through ISA bus interface. It consists of about 29,300 gates and performance of CPLD chip is about 44 Mbps encryption or decryption rate under 18 Mhz clock frequency and ECB mode.

  • PDF

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Effect of the Reactive Power Compensation System on Performance Enhancement in a 900 MW Combined Cycle Power Plant (무효전력보상장치 설치가 900 MW 복합화력발전소의 성능향상에 미치는 효과)

  • Lee, Young Ok;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.48-53
    • /
    • 2021
  • In the case of a 900 MW combined cycle power plant, most of the load on the site is a rotating device and is operated at a low power factor, and the power factor decrease increases the reactive power, which causes the efficiency of the device to be consumed and unnecessary unnecessary power consumption. This study intends to present the results by installing and operating a reactive power compensation device that absorbs and removes reactive power, which is a solution to this problem, on a 6.9 kV on-board bus. As a result of application of this system, first, it was confirmed that the power factor of the rotating machine was improved to 0.22 and the load power in the house was reduced by 1.4%, and the thermal efficiency of the generator was increased by 0.1% and the power generation power by 810 kW. Next, it was confirmed that the cost of construction and operation can be reduced in the future due to economic feasibility, with a decrease of 200 million won/year in electricity loss compared to 1.5 billion won in investment, an increase of 1 billion won/year in sales, and a one-year capital recovery period.