Study on the Performance Characteristics of the Roof Mounted Electrical Air Conditioning System Using Inverter Scroll Compressor  

Lee, Moo-Yeon (Thermal Management System Research Center, KATECH)
Won, Jong-Phil (Thermal Management System Research Center, KATECH)
Lee, Dong-Yeon (School of Mechanical Engineering, Yeungnam University)
Cho, Chung-Won (Thermal Management System Research Center, KATECH)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.12, no.10, 2011 , pp. 4308-4313 More about this Journal
Abstract
The objective of this study is to investigate the cooling performance of the roof mounted air-conditioning system using electric driven scroll compressor for zero emission vehicles. This air conditioner with air source was used R-134a as a refrigerant and tested under various operating conditions such as refrigerant charge amount and indoor temperature, and compressor frequencies. Experimental results revealed that at all tested compressor frequencies, heat transfer rate of the evaporator increased and the cooling COP increased with the indoor temperature. In addition, the heat transfer rate of the evaporator was over 25.0kW sufficient for the cooling loads of an electric bus.
Keywords
Cooling capacity; COP; Compressor work; Heat pump; R-134a;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cho, C. W., Lee, M. Y., Lee, H. S., Mo, J. H., Oh, S. T. and Won, J. P., "Heating Performance Characteristics of a Coolant Source Heat Pump using Wasted Heat of Electric Devices for an Electric Bus", Int. J. Automotive Technology, In Review, 2011.
2 Lee, M. Y., Cho, C. W., Lee, H. S., Lee, D. Y., Park, Y. C. and Won, J. P., "Performance Characteristics of a Simultaneous Hybrid Heat Pump using Coolant and Air Sources for an Electric Bus", Int. J. of Refrigeration, In Review, 2011.
3 Park, I. Y., Won, J. B., Goh, H. B. and Lim, K. S., "Optimum Control of A/C System for Hybrid Car by Electric Compressor", Proceeding of KSAE 2011, pp. 2155-2159, 2011.
4 Shin, S. K., Lim, S. J., Moon, J. H., Cho, Y., Koo, T. and Lee, S., "R-134a Heat Pump Application for the Buses by using Engine Coolant as a Heat Source", SAE, 2008-01-2697, 2008.
5 Kim, S. C., Park, J. C., Kim, M. S., "Performance Characteristics of a Supplementary Stack-Cooling System for Fuel-cell Vehicles using a Carbon Dioxide Air-conditioning Unit", Int. J. of Automotive Technology, 11(6), pp. 893-900, 2010.   과학기술학회마을   DOI