• 제목/요약/키워드: bundled conductors

검색결과 17건 처리시간 0.026초

Aerodynamic force characteristics and galloping analysis of iced bundled conductors

  • Lou, Wenjuan;Lv, Jiang;Huang, M.F.;Yang, Lun;Yan, Dong
    • Wind and Structures
    • /
    • 제18권2호
    • /
    • pp.135-154
    • /
    • 2014
  • Aerodynamic characteristics of crescent and D-shape bundled conductors were measured by high frequency force balance technique in the wind tunnel. The drag and lift coefficients of each sub-conductor and the whole bundled conductors were presented under various attack angles of wind. The galloping possibility of bundled conductors is discussed based on the Den Hartog criterion. The influence of icing thickness, initial ice accretion angle and sub-conductor on the aerodynamic properties were investigated. Based on the measured aerodynamic force coefficients, a computationally efficient finite element method is also implemented to analyze galloping of iced bundled conductors. The analysis results show that each sub-conductor of the bundled conductor has its own galloping feature due to the use of aerodynamic forces measured separately for every single sub-conductors.

송전선로에서 Spacer-Damper 설치시공의 중요성 (Importance of the Spacer-Damper Installation in Overhead Lines)

  • 이형권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.46-48
    • /
    • 2005
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors. they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, In order to control it, spacer dampers are installed in transmission lines with bundled conductors. Spacer damper installation is very important, it can cause damage to the conductors and spaer damper itself. This paper suggests importance of spacer damper installation in bundled conductor systems.

  • PDF

A Study on a Power Transmission Line Mobile Robot for Bundled Conductor Navigation

  • Seok, Kwang-Ho;Kim, Yoon Sang
    • International journal of advanced smart convergence
    • /
    • 제8권2호
    • /
    • pp.155-161
    • /
    • 2019
  • We introduces a mobile robot that can navigate on a power transmission line arranged in bundled conductors. The designs of the proposed robot are performed for navigation on bundled conductors, and the navigation method for bundled conductors and obstacle avoidance are presented. The robot consists of 13 degrees of freedom (DOF) with a symmetrical structure for the left and right parts, including the four wheel joints. The navigation method is designed using a combination of three motion primitives such as linear motion of counterbalancing box, linear motion of robot arm, and rotational motion of wheel part. To examine the performance of the proposed robot, navigation simulations are conducted using $ADAMS^{TM}$. The robot navigations were simulated on obstacle environments that consisted of two- and four-conductor bundles. Based on the simulation results, the performance of the proposed robot was reviewed through the analysis of the trajectories of end-effectors. We confirmed that the proposed robot was capable of achieving optimal navigation on bundled conductors that included obstacles.

초고압 송전선로의 다도체 구성에 따른 불평형 전류 해석 (Unbalace Current Analysis on the Bundled Conductors of the UHV Overhead Transmission Line)

  • 정연호;이형권;손홍관;조연규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1379-1381
    • /
    • 1999
  • The unbalance current on the bundled conductors of the UHV overhead transmission line is one of the factors affected on power transmission system. It is varied by distance between of bundled conductors and of phase to phase, phase arrangement. In this paper, we calculated unbalance current on the bundled conductors by a variety of line arrangements and also calculated magnetic field at the circumference of the line fed with this unbalance current.

  • PDF

송전선로 스페이서댐퍼 적정 설치방안 연구 (A Study on the Installation method of the Spacer Damper for Bundled T/L)

  • 이형권;손홍관;이동일;위화복;박완동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.436-438
    • /
    • 2003
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors, they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, They take the form of horizontal galloping, snaking or rolling, in which case all subconductors move together in unison. They can also take the form of the subspan oscillation, which appear as elliptical motions of the subconductors moving out of phase, mainly in the horizontal plane within a subspan. In order to decrease amplitudes of the oscillation, this paper examines the application status of the spacer dampers and suggests proper installation methods.

  • PDF

345kV 가공선로 진동다발 소경간에 대한 진동저감 대책(I) (A study on measures against subspan oscillation by spacers for 2 bundled conductors in 345kV overhead T/L)

  • 김우겸;이달형;신점식;이형권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.679-680
    • /
    • 2007
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying spacers for 2 bundled conductors to the subspans. In the future we will try to observe and analyze the oscillation after installing the spacers for 2 bundled conductors, and suggest the effective method for controling subspan oscillations.

  • PDF

154 kV 복도체 가공송전선로에서 전자력에 의한 소도체간 접촉 (Kissing of Sub-conductors due to Magnetic Forces in a 154 kV Bundled Overhead Transmission Line)

  • 김상범;노희원;김영홍;고광만;박종혁;김상수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.383-389
    • /
    • 2016
  • 국내 154 kV 복도체 가공송전선로를 대상으로 전자력에 의한 소도체간 접촉현상을 실증적으로 재현하고 대처 방안을 제시하였다. 도체에 흐르는 전류의 크기가 클수록, 스페이서의 간격이 클수록 소도체간에 작용하는 전자력은 크게 측정되었다. 스페이서 간격이 68 m일 경우 전류 크기가 2,000 A 일 때부터 소도체는 불안정한 상태가 되어 소도체간 간격이 변화하는 횡방향 진동이 시작되었다. 스페이서 간격이 136 m일 경우 전류 크기가 증가할수록 소도체간 간격은 좁아지다가 2,250 A 일 때 두 소도체는 완전히 접촉하였다. 스페이서 간격에 따른 전자력의 크기를 도식화하고 안전한 스페이서 간격을 제시하였다. 시험선로와 실선로 간에는 접촉현상이 발생하는 조건이 상이한 것으로 나타났으며, 이는 송전선로 가선 과정에서 도체에 가해진 여러 형태의 잔류 응력, 바람 조건 등의 차이 때문으로 판단되었다.

다도체 송전선로용 스페이서댐퍼 설계 (Spacer Damper Design for Bundled Conductor Transmission Lines)

  • 이형권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1235-1237
    • /
    • 1998
  • Spacer Dampers must be carefully designed and tested. Because it can protect conductors from conductor oscillations due to winds and electrical forces. If the spacer damper has any problems in itself, it may cause extensive damage to the transmission lines. This paper suggests a design method and considerations of spacer damper for bundled conductor transmission lines.

  • PDF

가공송전선로의 서브스판 진동에 대한 실험 및 실측 분석 (Field Observation and Analysis of Subspan Oscillatron in 4 Bundled Conductor Transmission Lines)

  • 손홍관;이형권;이동일;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.525-527
    • /
    • 2003
  • This paper presents a collection of a number of observations made on 4 bundled conductor transmission lines concerning the behaviour of conductors under the effect of natural winds. Namely in order to know the wind-induced vibration status and study wind-induced vibrations have been recorded and analyzed form the real transmission lines. By the field observation and analysis results, subspan oscillations among the wind-induced vibrations is known to be the main type of the vibrations. And some common characteristics of the observation sites, which have had high maintenance rate, can be found from the data also. It is considered that the main results described in this paper will be useful data and be used in controlling the subspan oscillations and protecting the conductors.

  • PDF

Field Observation and Analysis of Wind-Induced Vibrations in Four-Bundled Conductor Transmission Lines

  • Sohn, Hong-Kwan;Lee, Hyung-Kwon;Chu, Jang-Hee;Lee, Dong-Il;Lee, Eun-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.109-114
    • /
    • 2003
  • This paper presents observations made on four-bundled conductor transmission lines concerning the behavior of conductors under the effect of natural winds. To know the wind-induced vibration status and how to control it, wind-induced vibrations have been recorded and analyzed from the real transmission lines. From the field observation and analysis results, subspan oscillation was found to be the main type of vibration. In addition, the data also revealed some common characteristics of the observation sites with high maintenance rates. The results will be used in controlling the subspan oscillations and protecting the conductors.