• 제목/요약/키워드: bulk-limited current

검색결과 25건 처리시간 0.034초

Current Density Equations Representing the Transition between the Injection- and Bulk-limited Currents for Organic Semiconductors

  • Lee, Sang-Gun;Hattori, Reiji
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.143-148
    • /
    • 2009
  • The theoretical current density equations for organic semiconductors was derived according to the internal carrier emission equation based on the diffusion model at the Schottky barrier contact and the mobility equation based on the field dependence model, the so-called "Poole-Frenkel mobility model." The electric field becomes constant because of the absence of a space charge effect in the case of a higher injection barrier height and a lower sample thickness, but there is distribution in the electric field because of the space charge effect in the case of a lower injection barrier height and a higher sample thickness. The transition between the injection- and bulk-limited currents was presented according to the Schottky barrier height and the sample thickness change.

배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성 (Fault Current Limitation Characteristics of the Bi-2212 Bulk Coil for Distribution-class Superconducting Fault Current Limiters)

  • 심정욱;이해근;임성우;김혜림;현옥배;박권배;이방욱;오일성;김호민
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.277-281
    • /
    • 2007
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter (SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of $200V_{rms}$ and fault current of $12kA_{rms}\;and\;25kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of $12kA_{rms}\;and\;25kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}\;within\;0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLS.

고정화 효소전극을 이용한 포도당분석 (Glucose Analysis Using Free and Immobilized Glucose Oxidase Electrode)

  • 장호남;주대권;김영성
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.95-100
    • /
    • 1982
  • Glucose oxidase from A. niger was entrapped in polyacrylamide gel which was used in the enzyme electrode for glucose analysis. The electrode was assembled by placing the gel between the membranes on the surface of a Clark type electrode. In order to make it possible to analyze the experimental results later, the stagnation flow was adopted wheree the governing fluid mechanics were well known. The current increased with the increase concentration in the bulk below a certain level of glucose concentration beyond which no more current increase was observed. This is probably due to the diffusion limitation of oxygen from the bulk solution. Also the current increased witll the enzyme loading in the gel, but the linearity between the current and the glucose concentration was rather limited to a narrow range. Flow rate was found to be very important, which means that film diffusion is very important under the flow rate of 5cm/sec. As a conclusion, enzyme loading, gel layer thickness, stirring speed and bulk concentration of glucose were found to be most improtant parameters in yielding a linar current reponse with respect to the bulk glucose concentration.

  • PDF

배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성 (Fault current limitation characteristics of the Bi-2212 bulk coil for distribution-class superconducting fault current limiters)

  • 심정욱;김혜림;임성우;현옥배;이해근;박권배;김호민;이방욱;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.639-640
    • /
    • 2006
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter(SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of 200 $V_{rms}$ and fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}$ within $0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLs.

  • PDF

Critical currents across grain boundaries in YBCO : The role of grain boundary structure

  • Miller Dean J.;Gray Kenneth E.;Field Michael B.;Kim, Dong-Ho
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.14-19
    • /
    • 1999
  • Measurements across single grain boundaries in YBCO thin films and bulk bicrystals have been used to demonstrate the influence of grain boundary structure on the critical current carried across the grain boundary. In particular, we show that one role of grain boundary structure is to change the degree of pinning along the boundary, thereby influencing the critical current. This effect can be used to explain the large difference in critical current density across grain boundaries in thin films compared to that for bulk bicrystal. These differences illustrate the distinction between the intrinsic mechanism of coupling across the grain boundary that determines the maximum possible critical current across a boundary and the measured critical current which is limited by dissipation due to the motion of vortices.

  • PDF

2단계 스퍼터링으로 형성시킨 강유전 박막의 누설전류 개선 (Improvement of Leakage Current in Ferroelectric Thin Films Formed by 2-step Sputtering)

  • 마재평;신용인
    • 마이크로전자및패키징학회지
    • /
    • 제13권1호통권38호
    • /
    • pp.17-22
    • /
    • 2006
  • 2단계 스퍼터링으로 강유전 PZT 박막을 형성시켜 유전특성과 전도기구를 조사하였다. 또한 PZT 박막 내의 carrier를 보상해주기위해 도너 불순물을 도핑하였다. 2단계 스퍼터링으로 상온층 두에를 조절하여 누설전류를 $10^{-7}A/cm^2$ order까지 줄일 수 있었다. 전도기구가 bulk-limited의 하나임을 확인하였고 따라서 적정한 도너 불순물을 채택하였다. 도너 불순물을 도핑한 경우 2단계 스퍼터링한 PZT 박막의 누설전류 특성은 $10^{-8}A/cm^2$ order까지 개선되었다.

  • PDF

BSCCO 초전도 한류기의 동시퀜치 및 내력 시험 (Equal Quench and Endurance Test of the BSCCO Superconducting Fault Current Limiter)

  • 심정욱;박권배;이방욱;오일성;임성우;김혜림;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.933-934
    • /
    • 2007
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) based on BSCCO-2212 bulk coils. Each bulk coils of the SFCL was designed to have the rated voltage of 220 $V_{rms}$ and the critical current($I_C$) of 320$\sim$340 A at 77K. Ten components in series, make the SFCL having the rated voltage of 2.2 $kV_{rms}$ for equal quench test. The fault test was conducted at an input voltage of 2.2 $kV_{rms}$ and fault current of 25 $kA_{rms}$. In addition, we examined the endurance characteristics for all bulk coils through repeat fault test. Test results shows that the SFCL successfully limited the fault current of 25$kA_{rms}$ to below $7{\sim}8kA_{p}$ within minimum 1.1msec after fault occurred. All bulk coils quenched together upon faults and shared the rated voltage evenly. The endurance test results show an equivalent among repeat fault test. During the quench process, average temperature of all bulk coils did not exceed 250 K, and the SFCL was totally safe during the whole operation.

  • PDF

초고집적반도체의 커패시터용 강유전 박막의 전기적 특성 개선 (Improvement of Electrical Property in Ferroelectric Thin Films for ULSI's Capacitor)

  • 마재평;박삼규
    • 마이크로전자및패키징학회지
    • /
    • 제11권3호
    • /
    • pp.91-97
    • /
    • 2004
  • PZT 박막을 rf-마그네트론 스퍼터링으로 $Pt/Ti/SiO_2/Si$ 기판 위에 형성시켰다. $5\%$ 과잉 PbO 를 포함한 bulk PZT 타겟을 사용하였다. 상온에서 PZT 박막을 얇게 입힌 후 나머지 두께를 $650^{\circ}C$에서 in-situ 방법으로 형성시켰다. 강유전 특성을 갖는 PZT 상은 $650^{\circ}C$에서 형성되었다. 2단계 스퍼터링에 의해 누설전류 특성을 크게 증진시킬 수 있었고, 적절한 두께의 상온층을 포함시킨 경우 $2{\times}10^{-7}A/cm^2$의 매우 작은 누설전류를 나타냈다. 누설전류 기구에 대한 조사 결과, 여러 조건에서 제조된 PZT 박막의 전기전도는 모두 bulk-limit 기구에 의한 것임을 알 수 있었다.

  • PDF

The fabrication of bulk magnet stacked with HTS tapes for the magnetic levitation

  • Park, Insung;Kim, Gwantae;Kim, Kyeongdeok;Sim, Kideok;Ha, Hongsoo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.47-51
    • /
    • 2022
  • With the innovative development of bio, pharmaceutical, and semiconductor technologies, it is essential to demand a next-generation transfer system that minimizes dust and vibrations generated during the manufacturing process. In order to develop dust-free and non-contact transfer systems, the high temperature superconductor (HTS) bulks have been applied as a magnet for levitation. However, sintered HTS bulk magnets are limited in their applications due to their relatively low critical current density (Jc) of several kA/cm2 and low mechanical properties as a ceramic material. In addition, during cooling to cryogenic temperatures repeatedly, cracks and damage may occur by thermal shock. On the other hand, the bulk magnets made by stacked HTS tapes have various advantages, such as relatively high mechanical properties by alternate stacking of the metal and ceramic layer, high magnetic levitation performance by using coated conductors with high Jc of several MA/cm2, consistent superconducting properties, miniaturization, light-weight, etc. In this study, we tried to fabricate HTS tapes stacked bulk magnets with 60 mm × 60 mm area and various numbers of HTS tape stacked layers for magnetic levitation. In order to examine the levitation forces of bulk magnets stacked with HTS tapes from 1 to 16 layers, specialized force measurement apparatus was made and adapted to measure the levitation force. By increasing the number of HTS tapes stacked layers, the levitation force of bulk magnet become larger. 16 HTS tapes stacked bulk magnets show promising levitation force of about 23.5 N, 6.538 kPa at 10 mm of levitated distance from NdFeB permanent magnet.

주파수 의존성에 따른 고분자 LED의 유전 분산 거동에 관한 연구 (AC dielectric response of poly(p-phenylenevinylene) light emitting devices)

  • 이철의;김세헌;장재원;김상우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2000
  • AC impedance measurements on poly-p-phenylenevinylene (PPV) LEDs in the frequency range between 10 Hz and 10$\^$6/ Hz were carried out. The complex-plane impedance spectra indicate that PPV devices can be represented by equivalent circuits that corresponds to the bulk and interfacial regions at high and low frequencies, respectively. As a result of complex impedance analysis through the separation of bulk and interfacial region impedances, increase of forward bias in Al/PPV/ITO devices gave rise to relative decrease of the interfacial region impedance. Above the electric field of 10$\^$6/ V/cm the PPV device showed a space charge limited current (SCLC) conduction. The dependence of the transport mechanism and dielectric properties on the applied bias voltage is discussed.

  • PDF