• Title/Summary/Keyword: bulk type

Search Result 640, Processing Time 0.027 seconds

Delignification Kinetics of Trema orientalis (Nalita) in Kraft Pulping

  • Jahan, M. Sarwar;Rubaiyat, A.;Sabina, R.
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.5
    • /
    • pp.7-11
    • /
    • 2007
  • Kraft pulping of Trema orientalis (Nalita) was studied in order to find kinetic data for delignification. Pulping runs were carried out in the temperature range of $160-180\;^{\circ}C$ under constant and well-defined conditions. The delignification was found to be first order with respect to residual lignin and was chemically controlled. The rate of delignification reaction was increased 1.11-1.23 for $10\;^{\circ}C$ temperature increase in the range of $160-180\;^{\circ}C$ range. A mean value of 93% of lignin was removed at the transition between bulk and residual delignification. The influence of cooking temperature on the rate constant was expressed by an Arrhenius-type equation. The obtained activation energy of the delignification reaction was 6,164 cal/mol. The transition point between bulk and residual phase was shifted to lower lignin and carbohydrate yield with the increase of temperature.

Comparison of linewidth enhancement factor and differential gain of DFB-LDs with various active layter structures (활성층 구조에 따른 DFB-LD의 선폭확대계수 및 미분이득 비교)

  • 박경현;조호성;장동훈;이중기;김정수;이승원;김홍만;박형무
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.8
    • /
    • pp.86-93
    • /
    • 1995
  • Linwidth enhancement factor .alpha., linwidth, chirping and differential gain characteristics were measured and compared for each DFB-LDs containing active layers composed of bulk, MQW, and S-MQW, respectively. .alpha. of 6, 4 and 3.2 and chirping measured under 2.5Gbps modulation of 1.29nm, 0.67nm and 0.48nm were given for DFB-LDs of bulk, MQW and S-MQW active layers, respectively. And S-MQW has the largest differential gin of 2.4*10$^{-15}$ cm$^{2}$ (S-MQW) compared to the of 5.4*10$^{-16}$ cm$^{2}$(bulk) and 8.6*10$^{-16}$ cm$^{2}$(MQW). Linewidth enhancement facter .alpha. of less than 2 is expected with p-type modulation doped S-MQW DFB-LD.

  • PDF

Development of Electric Hoist Device for Rack in Tobacco Bulk curing Barn (담배 벌크건조기의 래크용 전동발달기 장치 개발)

  • 김용암;류명현;백종운
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.90-93
    • /
    • 2001
  • In order to save hanging labor hours and reduce work intensity for bulk curing of the flue-cured tobacco, and electric hoist was developed. It consists of a pair of square steel frames with side plates and rolling casters to move back and forth on the second tire of bulk barn, and wire rope type lift was attached to the beneath of its top center. The lift driven by DC motor could be controlled by operating switch with one limit switch and control box, and a scissors shaped gripper was deviced to grip tobacco rack to the end of wire rope. As the results of experiments with electric hoist, labor hours for hanging could be saved by 30 to 40% as compared with those in conventional method. With simple and light structure, it was possible for even woman to load the harvested tobacco, and it could be recommended for farmers to use this device with reasonable price.

  • PDF

Measurements of Voltage & Current from MV Class GIS Using a Bulk Type Optical Sensor (Bulk Type Optical Sensor를 이용한 MV급 GIS의 전압.전류 측정)

  • Park, J.N.;Lee, S.W.;Kim, Y.G.;Lee, H.S.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1658-1660
    • /
    • 2004
  • Use of higher voltage and higher capacity of power systems and their equipment is leading to an increase in the size of the entire system. In order to reduce the cost of constructing a substation, it is necessary to reduce the size of equipment. So, this paper described optical sensor, which exploited the electric and magnetic potentiometer to sense the measured voltage and current of medium voltage GIS. It can be used both in measurement and in protection relays as its well linearity, rapid response, broad dynamic range, wide frequency band, no magnetic saturation, small in volume, light weight, and saft in insulation.

  • PDF

An X-ray Diffraction Study on ZrH2 under High Pressures (고압하에서 ZrH2에 대한 X-선 회절 연구)

  • 김영호
    • Journal of the Mineralogical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • Polycrystalline ZrH2 in tetragonal crystal system has been compressed in a modified Bassett-type diamond anvil cell up to 36.0 GPa at room temperature. X-ray diffraction data did not indicate any phase transitions at the present pressure range. The pressure dependence of the a-axis, c-axis, c/a and molar volume of ZrH2 was determined at pressures up to 36.0 GPa. Assuming the pressure derivative of the bulk modulus (K0') to be 4.11 from an ultrasonic value on Zr, bulk modulus (K0) was determined to be 160Gpa by fitting the pressure-volume data to the Birch-Murnaghan equation of state. Same sample was heated at $500^{\circ}C$ at the pressure of 9.8 GPa in a modified Sung-type diamond anvil cell. Unloaded and quenched sample revealed that the original tetragonal structure transforms into a hexagonal structured phase with a zero-pressure molar volume change of ~115.5%.

  • PDF

Qualification of liquid crystal mixtures by bulk-state transient current analysis

  • Peng, Kang-Yung;Yin, Hsueh-Min;Lin, Yang-Chu;Wang, Yang-Long;Kung, Li-Wei;Chan, Meng-Xi;Cheng, Hsin-An;Liau, Wei-Lung;Lien, Alan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.855-858
    • /
    • 2008
  • Transient current (TC) on bulk-state liquid crystal mixtures was measured. We found that TC is very sensitive to impurities and the features of TC curves depend on the type of contamination, from which the quality of materials can be definitely evaluated and the type of impurities can also be revealed.

  • PDF

Clamp-type Bulk Optic Current Sensor (클램프헝 부피 광 전류센서)

  • Chung, Hyun;Lee, Yong-Wook;Kim, Soo-Gil;Lee, Byoung-Ho;Park, Byoung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1924-1926
    • /
    • 2002
  • The optical current transformer using Faraday effect is the sensor to measure current that flows in any conductor. This sensor doesn't undergo the magnetic saturation and effect of adjacent conductors. But this senor using bulk-glass sensing clement has crucial drawback. It is impossible that the sensor is mounted to conductor without breaking the closed-loop of light or conductor. So we developed the clamp-type optical current transformer and made an experiment.

  • PDF

Microstructure and Mechanical Properties of Mg-Zn-Y-Yb Alloys Produced by Consolidation of Rapidly Solidified Ribbons

  • Sakamoto, Yoshihito;Yamasaki, Michiaki;Kawamura, Yoshihito
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1045-1047
    • /
    • 2006
  • Fabrication of $Mg_{95.75}Zn_1Y_3Yb_{0.25}$ bulk alloy has been performed through the consolidation of rapidly solidified ribbons. The $Mg_{95.75}Zn_1Y_3Yb_{0.25}$ bulk alloy exhibited excellent mechanical properties, high tensile yield strength of 530 MPa, and large elongation of 3 %. Microstructure of the alloy was characterized by equiaxed fine grains that consist of -Mg, long period ordered (LPO) structure phase, and $Mg_5RE$-type cubic compound. The strengthening of the alloys may be due to fine grains with LPO structure phase and $Mg_5RE$-type compound.

  • PDF

A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement (혈압 측정을 위한 외팔보형 접촉힘 센서 어레이)

  • Lee, Byeung-Leul;Jung, Jin-Woo;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

A Low-Voltage Vibrational Energy Harvesting Full-Wave Rectifier using Body-Bias Technique (Body-Bias Technique을 이용한 저전압 진동에너지 하베스팅 전파정류회로)

  • Park, Keun-Yeol;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.425-428
    • /
    • 2017
  • This paper describes a full-wave rectifiers for energy harvesting circuit using a vibrational energy. The designed circuit is applied to the negative voltage converter with the body-bias technique using the Beta-multiplier so that the power efficiency is excellent even at the low voltage, and the comparator is designed as the bulk-driven type. The proposed circuit is designed with $0.35{\mu}m$ CMOS process, and The designed chip occupies $931{\mu}m{\times}785{\mu}m$.

  • PDF